IMPORTANT:
Water lines MUST be thoroughly flushed BEFORE and
AFTER installing the faucet to prevent foreign matter, i.e.
copper chips, sand, stones, etc. from clogging and possibly
damaging the faucet.
GENERAL
This installation and Maintenance Guide introduces the
installation, maintenance and use of the Ultra-Sense faucet.
Please read the instructions carefully prior to the installation
and save them for reference where service may be needed.
If any fault or malfunction occurs in the faucet, please refer
to the troubleshooting chart, or contact Symmons Customer
Service at 1-800-SYMMONS.
TECHNICAL DATA
Aft er fl ow period: 1 second
■
Maximum water fl ow period: 10 seconds
■
Electrical installation: 2CR5 6V Lithium Battery
■
Working pressure: 14.5psi - 145psi
■
Normal water fl ow: .25GAL/cycle
■
INSTALLATION
Every S-6080 Series faucet can be installed in one of three
possible supply configurations.
OPTIONS
Hot and cold supply with lever handle temperature
■
adjustment. (factory standard)
Hot and cold supply with preset tempered water.
■
(fi eld modifi ed)
Single supply for pre-mixed water. (fi eld modifi ed)
■
OPTION 1
For 4” center deckplate installation, place faucet and
■
supply(s) through deck plate (SF-138).
Affi
x deck plate with studs facing down to faucet using two
■
screws (SF-143) provided in mounting kit (SF-142).
NOTE: For S-6080-LST (18” long copper supply tube)
thread supply tubes into faucet housing. Tubes thread into
base with LEFT hand thread. Be sure brass tube bushing
with o-ring is fully installed in base and tight.
Mount the faucet on the wash basin using anchor bar (KN-
■
23), spacer (KN-26), and nut (L-36) on 4” centers. Ensure
the gasket (SF-140) is correctly positioned between the
faucet and wash basin. For single hole mount installation,
attach studs found in single mount kit (SF-158) to base of
1
2
3
Lavatory Faucet
S-6080
Battery Powered, Sensor-Operated
Installation and Service Instructions
Ultra-Sense
™
housing. Place faucet supply(s) through wash basin and
secure using wing fi xing plate and nuts from single mount kit.
Attach supply hose(s) (SF-148) to check strainer assembly
■
(SF-186).
Connect check strainer assembly (SF-186) to angle stop or
■
water inlet pipe.
NOTE: For S-6080-LST (18” long copper supply tubes) attach
check strainer assembly (SF-181) directly to supply stops. Cut
tubing to proper length and attach tubing to check strainer
assembly using nut (IL-8)) and ferrule (IL-9).OPTION 2
Modifying the faucet for hot and cold supply with
tempered water
Remove handle screw (SF-155), handle (SF-154) and
■
handle limit stop (SF-156).