TECHNICAL DATA

BATTERY POWERED

S6350B

ELECTRICAL POWERED

S6350E

BATTERY POWERED WITH MIXER

S6350BM

ELECTRICAL POWERED WITH MIXER

S6350EM

Power supply:

6 X 1.5V AA batteries or 12V transformer

Recommended water 

pressure:

0.5-8.0 bar (7-116 PSI)

With water pressure of more than 8 bars,

use a pressure reducing valve for reduction.

Preset sensor range:  

200mm / 7.87” (customizable with optional remote control)

Minimum sensor range: 

35mm / 1.38”

Maximum sensor range: 

300mm / 11.81”

Security time:

90 seconds (can be reduced with optional remote control)

Hot water temperature:

Max 70˚C

The information in this document reflects products at the date of printing. The manufacturer reserves the right,  subject to all applicable laws, at any time, at its sole discretion, and 

without notice, to discontinue or change the features, designs, materials and other specifications of its products, and to either permanently or temporarily withdraw any of the for-

going from the market. All information in this document is provided “as is” without warranty of any kind, either expressed or implied, including but not limited to any implied war-

ranties of merchantability, fitness for a particular purpose, or non-infringement. The manufacturer assumes no responsibility for errors or omissions in the information presented 

in this document. In no event shall the manufacturer be liable for any special, incidental, indirect or consequential damages of any kind, or any damages whatsoever arising out of 

or in connection with the use or performance of this information. The tradenames, trademarks, logos and service marks presented in this document, including their design, are the 

property of the manufactureror other third parties and you are not permitted to use them without the prior written consent of the manufacturer or such third party as may own them.

TECHNICAL DATA

2-3 

PACK CONTENTS

PRE-INSTALLATION INFO

5-6 

INSTALLATION

7-8 

SETTINGS ADJUSTMENT

 

BATTERY REPLACEMENT

10 

SPARE PARTS LIST

11 

MAINTENANCE

12 

LIMITED WARRANTY

13 

TROUBLE SHOOTING

Содержание S6350B DIA ACTIVSENSE

Страница 1: ...INSTALLATION AND MAINTENANCE GUIDE INSTALLATION AND MAINTENANCE GUIDE S6350B E DIA ACTIVSENSETM ELECTRONIC LAVATORY FAUCET...

Страница 2: ...y withdraw any of the for going from the market All information in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied war...

Страница 3: ...e included 1 X FAUCET AND ATTACHMENTS 1 X FAUCET AND ATTACHMENTS DIA ULTRA SENSE DIA ULTRA SENSE WITH MIXER 1 X DECK PLATE NOT INCLUDED 0 35 GPM AND 1 0 GPM AERATORS 1 X DECK PLATE NOT INCLUDED 1 x Al...

Страница 4: ...ing Please note the housing is marked the the flow rate of the supplied aerator PRE INSTALLATION INFO IMPORTANT All plumbing is to be installed in accordance with applicable codes and regulations CHEC...

Страница 5: ...wing Shut off the water supply In order to adjust the sensor with the remote control hold the remote control straight in front of the sensor in a distance of about 6 8 15 20cm Choose the function you...

Страница 6: ...t if the sensor is covered for more than 90 seconds the water flow will shut automatically To resume regular operation any obstruction must be removed Press the SEC button Wait until a quick flashing...

Страница 7: ...e clogged The filter s can be cleaned as follows 1 Shut off the water shut off valve angle valve 2 Disconnect the flexible pipe s 3 Remove the filter s and wash it them under running water 4 Reassembl...

Страница 8: ...aucet s body is higher This situation could be caused by a sudden increase in the water supply pressure that the back check prevents from dropping even after water supply pressure drops under 8 bars C...

Страница 9: ...Symmons Industries Inc 31 Brooks Drive Braintree MA 02184 3804 1 800 796 6667 03 2021 01500505 C...

Отзывы: