Symmons Origins S-9601P-RP Скачать руководство пользователя страница 3

3

Installation

G

J

2)  Install shower escutcheon (G) to 

shower valve.  Secure with two 
screws (F).

1

G

F

2

1)   Install  diverter  handle  or  volume        

control  handle  (J)  into  shower                
escutcheon (G).

3)  Install dome cover (E) to valve by 

turning clockwise.

E

1

2

4)  Install handle (D) to valve and 

secure with set screw (H). Install 
plug button (I).

H

I

D

1

2

5)  Attach shower arm (B) and flange 

(C) to vertical shower pipe. Turn 
clockwise to tighten.

B

1

2

C

Installation note:  

For valve body installation, please see valve body manual.

Note: 

Handle should be facing the 12 

o’clock position. 

6)  Install showerhead (A) to shower 

arm (B). Turn clockwise to tighten.

B

1

2

A

1)  Turn shower handle counter-

clockwise approximately 1/4 turn 
to put valve in cold position.

2)  Turn shower handle counter-

clockwise approximately 1/2 turn 
to put valve in warm position.

3)  Turn shower handle counter-

clockwise approximately 3/4 turn 
to put valve in hot position.

Operation (Temperature Control)

Содержание Origins S-9601P-RP

Страница 1: ...ew to limit handle turn integral service stops to allow water shutoff at valve for service S 9601 XP RP only integrated volume control 1 mode showerhead with easy to clean rubber nozzles and standard...

Страница 2: ...ter Supply COLD Water Supply B C D E F I F G H J Parts Breakdown Notes 1 Apply a bead of silicone around the perimeter of all shower trim installed flush to the finished wall Leave opening on bottom o...

Страница 3: ...vertical shower pipe Turn clockwise to tighten B 1 2 C Installation note For valve body installation please see valve body manual Note Handle should be facing the 12 o clock position 6 Install showerh...

Страница 4: ...ubleshooting Chart Problem Cause Solution Finish is spotting Elements in water supply may cause water staining on finish Clean finished trim area with a soft cloth using mild soap and water or a non a...

Страница 5: ...a con un tornillo con tope ajustable para limitar el giro de la manija un regulador integrado del caudal de agua una cabezal de ducha de 1 funci n con boquillas de goma f ciles de limpiar y un restric...

Страница 6: ...I F G H J Suministro de agua FR A Suministro de agua CALIENTE Desglose de piezas Herramientas requeridas Llave inglesa Llave Allen 1 8 Destornillador phillips Cinta de tefl n Silicona Notas 1 Aplique...

Страница 7: ...jas del reloj para ajustarlos B 1 2 C Nota Para instalar el cuerpo de la v lvula vea el manual Nota El mango debe situarse en la posici n de las 12 6 Instale el cabezal de ducha A al brazo de la ducha...

Страница 8: ...as en el suministro de agua pueden provocar que el agua manche el acabado Limpie el rea con acabado con un pa o suave usando jab n suave y agua o un limpiador no abrasivo y luego enjuague r pidamente...

Отзывы: