Caution:
Be sure to turn off hot and cold water supplies
before installing or servicing faucet.
Installation Procedure
1.
Push valve bodies through holes in sink from
underneath. Make sure
flange nuts
and
mounting
washers
are on underside of sink. Valve with red striped
hose (hot) is on the left and blue (cold) is on the right.
Put gasket (LN-129) over
valve body
. Thread escutcheon
(LN-128) onto
valve body.
The top of the valve spindle
should measure 1-7/8” from mounting surface (See
rough in drawing).
2.
Thread collar (LN-112) on to valve body until it reaches
the escutcheon (LN-128).
3.
CRP handle installation: Ensure valve spindle is rotated
to the OFF position. Place handle on valve spindle and
thread screw (LN-121A) into valve.
4.
Tighten
flange nuts
and
mounting washers
from
underneath sink and secure with
mounting screws
if
necessary.
5.
Install spout (LN-254A) and centerbody (LN-188)
through center in sink hole from above sink. Secure
spout to sink with washer (LN-138) and nut (SPF-26).
Washer (LN-138) flat side should face back of the sink.
Thread tee (LN-189) to bottom of centerbody (LN-188).
6.
Thread
flex hose adapters
into tee (LN-189) using pipe
sealant on the threads. Attach
flex hoses
to
flex hose
adapters
.
7.
Connect hot supply to left tube and cold supply to right
tube using appropriate connectors.
8.
Pop-up drain installation:
a )
Remove pop-up plug, tail piece and flange from
the drain body. Make sure that locknut is threaded
all the way down onto the body with flat friction
washer in middle and beveled washer on top.
b )
Apply plumbers putty or sealant to bottom of
flange.
c )
Install drain body through drain opening in
lavatory and screw flange onto the drain body
making sure that the threads are completely
engaged for proper sealing and strength of the
connection. Apply joint compound to all threaded
parts to insure proper seal. Apply putty or teflon
tape to tail piece before attaching to drain body.
d )
Tighten locknut to compress the beveled flange
evenly across the bottom of the drain opening taking
care not to over tighten the locknut, causing damage
to the lavatory. Apply teflon tape (clockwise) on tail
piece and thread into outlet of body.
e )
Insert pop-up plug and pivot rod into body and
tighten retaining nut until the ball is seated on the
ball washer.
Note: The pop-up plug can be installed either in the
removable or non-removable position, depending
on the location of the hole located in the guide at
the bottom of the plug.
f )
Slide the pivot rod through one side of the spring
clip, then the appropriate adjustment hole and then
other side of the spring clip.
g )
Insert lift rod through faucet housing and the top of
the lift strap and secure it in place by tightening the
screw.
Note: To insure proper operation of lift rod and
pop-up, some adjustment of the linkage may be
required.
There are two possible adjustment points:
1) lift strap to lift rod
2) lift strap to pivot rod
8.
It is very important to thoroughly flush the supply lines
to prevent foreign matter, i.e. copper chips, sand, stones,
etc. from damaging the sealing surfaces of cartridge.
Remove aerator and open hot and cold to full open then
open both supplies. Let water run through hot and cold
long enough to flush supply lines thoroughly. Shut off
faucet and replace aerator. Check for leaks.
Replacing cartridge (KN-113 or KN-114):
1.
Remove plug button (LN-243H or LN-243C), loosen
Phillips head screw (LN-121A) and remove handle (LN-
177).
2.
Remove collar (LN-112) by turning counter clockwise.
Caution: Do not use wrench as this may damage the
surface finish.
3.
Place wrench on cartridge hex nut (KN-113, KN-114).
Turn wrench counterclockwise until cartridge is
removed.
4.
Install new cartridge. Turn cartridge with wrench until
cartridge does not turn easily then turn 1/4 to 1/2 turn
further. Reassemble handle in reverse fashion.
Widespread Lavatory Faucet
SLW-4412
Installation and Service Instructions
Carrington
™