Symmons Allura Trim 4703-TRM Скачать руководство пользователя страница 6

Symmons Industries, Inc.  

  31 Brooks Drive  

  Braintree, MA 02184  

  Phone: (800) 796-6667  

■  

Fax: (800) 961-9621

©2015 Symmons Industries, Inc.  

  www.symmons.com  

  [email protected]  

  ZV-3061 REV B  

■  

020315

1)  Turn shower handle counterclockwise approximately 

1/4 turn to put valve in cold position.

2)  Turn shower handle counterclockwise approximately 

1/2 turn to put valve in warm position.

3)  Turn shower handle counterclockwise approximately 

3/4 turn to put valve in hot position.

1)  Diverter handle facing straight down is for diverter 

function 1.

2)  

4705-TRM:

 Turn diverter handle counterclockwise one 

full revolution for diverter function 2.

 
     

4706-TRM:

 Turn diverter handle counterclockwise 1/4 

turn for diverter function 2.

3)  

4706-TRM:

 Turn diverter handle counterclockwise 3/4 

turn for diverter function 3.

4705-TRM

4706-TRM

Temperature Control

Diverter Control

Operation & Maintenance

Troubleshooting Chart

Finish is spotting.

Elements in water supply may cause 

water staining on finish.

Clean finished trim area with a soft 

cloth using mild soap and water or a 

non-abrasive cleaner and then quickly 

rinse with water.

Содержание Allura Trim 4703-TRM

Страница 1: ...als plated in standard polished chrome finish Allura Trim Series Operation Maintenance Manual 4703 TRM 4705 TRM 4706 TRM 4703 TRM Valve Trim with Hand Shower Compliance 1 5 1 5 gpm 5 7 L min flow restrictor 2 0 2 0 gpm 7 6 L min flow restrictor LAM Metal finish insert handle LR Lever handle 4705 TRM Shower Trim with Hand Shower Note Append appropriate suffix to model number STN Satin Nickel finish...

Страница 2: ...hread must be recessed 1 4 from finished wall E 6 152 mm right or left F Ref 77 1956 mm G Ø 7 178 mm H Ø 5 127 mm I 10 254 mm J 4 3 4 121 mm K 2 1 2 64 mm L Ref 32 813 mm 4706 TRM Ref 42 1067 mm 4703 TRM 4705 TRM M 12 305 mm N 3 1 8 79 mm O 4 1 8 105 mm P 1 2 NPT Q 4 102 mm R Rough in 2 3 8 1 2 60 mm 13 mm S 5 1 2 140 mm A C C H H G G K K L L M M F F B B D D J J I I N N O O R R S S Q Q P P E E Flo...

Страница 3: ...over LockNut T 19 20 PL S L T Dial Mounting Screws Shower Escutcheon T 133C U Hand Shower HS 143 V Tub Spout 060 W 5 Hose with Vaccum Breaker EF 104 Tools Required for Installation Adjustable wrench Allen wrench 3 16 Phillips head screwdriver Plumber tape Silicone Note Apply a bead of silicone around the perimeter of the escutcheons after installing trim flush with wall Leave opening on bottom of ...

Страница 4: ...utcheon K to plastic mounting plate M Note Tabs should snap into place 4 Install diverter dome cover R to diverter valve and secure with lock nut Q 5 Install shower dome cover J to shower valve by turning clock wise 6 Install diverter handle 4705 TRM and 4706 TRM only and shower handle I to valves Secure han dle s with star washer H and screw G Attach plug button F to handle s Notes Handles should...

Страница 5: ...r of wall cradle N Install cradle mount P Secure with three screws O Replace cover on hand shower cradle 11 Attach shower arm D and flange E to vertical shower pipe turning clockwise to tighten 12 Install showerhead C to show er arm D turning clockwise to tighten 13 Attach large end of hand show er hose W to hand shower U Connect in line vacuum breaker to wall elbow B Turn clock wise to tighten 1 ...

Страница 6: ...hot position 1 Diverter handle facing straight down is for diverter function 1 2 4705 TRM Turn diverter handle counterclockwise one full revolution for diverter function 2 4706 TRM Turn diverter handle counterclockwise 1 4 turn for diverter function 2 3 4706 TRM Turn diverter handle counterclockwise 3 4 turn for diverter function 3 4705 TRM 4706 TRM Temperature Control Diverter Control Operation M...

Отзывы: