Maintenance (Cartridge Replacement)

E

2

A

C

D

1

D

E

2)  Inspect cartridge for debris.    

Replace cartridge if necessary. 

4)  Align spindle extender (C) with 

broach on cartridge (D). Install 
spindle extender (C) and cap 
assembly (A) to cartridge (D).       
Secure cap assembly (A) by   
turning clockwise.

D

2

1

A

C

Notes:

  

1) Use caution not to dislodge

cartridge from valve body when
installing cap assembly (A).

2) Tighten cap assembly (A) to  

75 ± 5 lbf-in of torque.

3)  Orient new cartridge (D) with 

arrow facing down. Align pegs on 
cartridge (D) with indents inside 
diverter valve (E).

1)  Remove cap assembly (A) from 

diverter valve by turning coun-
terclockwise. Remove cartridge 
extender (C) and cartridge (D).

Note:

  Spacer (B) will be seated 

inside cap assembly (A). 

Troubleshooting Chart

Problem

Cause

Solution

Diverter valve will not divert water.

Foreign matter in water supply may 

cause blockages in plumbing lines and 

the diverter valve cartridge.

Remove cartridge from diverter valve.  

Flush lines free of foreign matter.  

Inspect cartridge for debris.  Replace 

cartridge if necessary.

Water is leaking from the face of the 

diverter valve.

Cap assembly is not fully sealed to 

diverter valve.

Remove cap assembly. Inspect 

threads for debris.  Reinstall cap      

assembly to diverter valve at 75 ± 5 

lbf-in of torque.

Diverter trim will not install to diverter 

valve.

Diverter valve body rough-in is too 

deep.

Use RTS-DIV-1EXT-NS to extend      

diverter stem 1 inch.

WARNING:

  This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth defects, or 

other reproductive harm.  For more information, go to www.P65Warnings.ca.gov.

Содержание 3DIVBODYNSSRT

Страница 1: ... with diverter valve 2 Dimensions subject to change without notice 3DIVBODYNSSRT Triple Outlet Diverter Non Sharing ASME A112 18 1 CSA B125 1 B B IN IN OUT OUT OUT OUT A A OUT OUT C C D D F F G G E E Measurements A 2 5 8 67 mm B Screwless Escutcheons Hole Size Min Ø 3 76 mm Max Ø 3 1 4 83 mm C Screw Escutcheons Hole Size Min Ø 1 3 4 44 mm Max Ø 2 51 mm D 5 1 4 133 mm E 4x 1 2 male IPS 4x 1 2 sweat...

Страница 2: ...ber A B Cap Assembly Spacer RTS DIVCAP NS SRT C Cartridge Extender RTS DIVEXT NS SRT D Cartridge RTS 3DIV NS B G H I Spacer 1 Cap Extender 1 Cartridge Extender 4 Mounting Screws RTS DIV 1EXT NS E FROM SHOWER VALVE DIVERTER FUNCTION 1 DIVERTER FUNCTION 2 DIVERTER FUNCTION 3 C D A B G H B I Important Cartridge D must be installed with arrow facing down ...

Страница 3: ...r tape to male IPS threads on the inlet and outlet ports of diverter valve Install 1 2 14 NPT copper fittings to the inlet and outlet ports Connect outlets to desired accessories Operation 1 POSITION 1 1 Cartridge is factory set to divert to function 1 2 POSITION 2 2 Turn handle to position 2 to divert to function 2 Note Securing stringer mounts is necessary for applications where PEX or other non...

Страница 4: ...kwise Remove cartridge extender C and cartridge D Note Spacer B will be seated inside cap assembly A Troubleshooting Chart Problem Cause Solution Diverter valve will not divert water Foreign matter in water supply may cause blockages in plumbing lines and the diverter valve cartridge Remove cartridge from diverter valve Flush lines free of foreign matter Inspect cartridge for debris Replace cartri...

Отзывы: