6
CONNECTING TO A DATA LOGGER
6.1
CONNECTIONS
TILTOMETER GENERIC
DATA
LOGGER
STYLITIS-41 STYLITIS-101
(1)
BATTERY
Screw #10 BAT-
-
-
-
BAT
−
Screw #9 BAT+12V
-
-
-
BAT +
Screw #1 AZIMUTH
ANALOG CHANNEL ANY ANALOG IN
ANY ANALOG IN -
Screw #2 ELEVATION ANALOG CHANNEL ANY ANALOG IN
ANY ANALOG IN -
Screw #3 AN. GND
ANALOG GROUND GROUND
GROUND
-
6.2
SETTINGS
These settings deliver recorded values from 0 to 360 degrees for azimuth and from -90 to 90
degrees for elevation:
Data loggers with a 0 to 5V input range:
AZIMUTH
ELEVATION
SLOPE 72.0
36.0
OFFSET 0.0
-90.0
Data loggers with a 0 to 2.5V input range
(2)
:
AZIMUTH
ELEVATION
SLOPE 144.0
72.0
OFFSET 0.0
-90.0
NOTES:
(1) On Stylitis-101, connect the AN [-] inputs to the GND on the screw terminal. Set the input
range to 0~5V, Unipolar.
(2) For data loggers with input range equal to 0~2.5V, use the RS232 port to set the
Tiltometer’s output range to half. Issue the command: !RANGE=HALF (See 3.2).
(3)
S-UME-TILT_1_0-004