TMSL 097-44018-26
Issue 2: Sep 99
Page 90
COMMAND CODE: RTRV-COND
PURPOSE
RETRIEVE CONDITIONS
This command displays the current standing alarms, events, or state associated with one or more speci-
fied equipment units or facilities.
INPUT FORMAT
RTRV-COND-{EQPT|PORT}:[<tid>]:<aid>:<ctag>;
The following values can be used for the variables in the table below:
a
= 1–2
e
= 1–4 or ALL
b
= 1–11
f
= 2–4 (f > e)
c
= 1–12 (1–10 for TOTA-5 & TOTA-M)
g
= 1–10 (1–20 for EA20) or ALL
d
= 1–2 or ALL
h
= 2–10 (2–20 for EA20) (h > g)
RESPONSE FORMAT
<sid> <date> <time>
M
<ctag> COMPLD
"<aid>:<ntfcncde>,<typerep>,<srveff>,<conddescr>"...
;
Refer to Table A and Table F for parameter values.
command
aid
RTRV-COND-EQPT
CLK-a
DCIM-a
GTI-a
LTI-a
MCA
MRC-a
PSM-b
SHELF
TO-c
RTRV-COND-PORT
DCIM-a-d
MRC-a-e[&&-f]
PSM-b-e[&&-f]
TO-c-g[&&-h]