TimeAnalyzer 7x00 User’s Guide
098-00208-000 Revision A – February, 2010
Chapter 3 Configuring
Configuring TP5000 Module Using TimeMonitor PDV
Setting IP Address for MGMT Port of TP5000 Probe Module
The TimeProvider 5000 module supports static IP addresses (default) as well as
dynamically allocated addresses on the MGMT (Management) port. The
dynamically allocated address requires a connection to a DHCP server. When
provisioning the unit for static IP address, you can set the Host address, Mask
address, and Gateway address, or you can set the addresses to the factory default.
To set up and manage the TP5000 probe module with a terminal or a computer with
terminal emulation, you must establish either a serial connection or an Ethernet
connection.
Communicating Through the Serial Port
An EIA-232 serial port is available on the IMC module for a direct serial connection
to a terminal or a computer with terminal emulation. Use the following procedure to
connect the TP5000 probe module to a terminal or a computer with terminal
emulation via a straight through serial cable:
1. Connect one end of a straight-through serial cable to the serial port on the
computer or terminal and the other end to the EIA-232 connector on the IMC.
2. Configure the emulation software for 8 data bits, 1 stop bit, no parity, 57600 baud
rate, and no flow control. For details on how to do this with TimeMonitor PDV, see
3. Start the terminal emulation software and press
Enter
. The system prompt
should appear. If it does not, recheck each step in this procedure.
4. Type your user name and press
Enter
. The system prompts for a password.
5. Type your password and press
Enter
. The system prompt appears.
Note:
Before you can communicate with the TP5000 probe module
through an Ethernet connection, you must first configure the Ethernet
port using the serial connection.
Note:
For information on restricting user access, see
TP5000 Module’s User Access List
Note:
The unit’s default user name is “admin” and the default
password is “
symmadmin**
”.