098-00208-000 Revision A – February, 2010
TimeAnalyzer 7x00 User’s Guide
55
Chapter 3 Configuring
Configuring TP5000 Module Using TimeMonitor PDV
Configuring PDV to Communicate with TP5000 Probe Module
The TP5000 PTP probe module in the TimeAnalyzer 7x00 provides two
communication interfaces: RS-232 and TCP/IP. TCP/IP should be used for making
measurements due to speed limitations on the RS-232 port. Either TCP/IP or
RS-232 can be used for configuration.
Configuring RS-232 Parameters
The serial interface for the TP5000 probe module is fixed at the following settings.
There is no handshaking.
Baud rate- 57600
Stop bit - 1
Parity - 0
Data length- 8
Flow control- none
To configure TimeMonitor PDV and the computer for the TP5000 module serial
interface parameters:
1. Make sure that the radio button for the
Disconnect
mode is selected.
2. Select the
RS-232
radio button.
3. Click the button on the right side of the RS-232 radio button to display the
RS-232 Settings dialog.