Chapter 2 TL1 Reference
System Security
32
SSU-2000e Technical Reference
12713140-003-2 Revision E.01 – January 2007
System Security
The operating software of the SSU-2000e includes a subset of GR-815 security
requirements, including user lockout, password aging, and login failure attempts. New
commands allow an Administrator-level user to query the security log, set the login
failed attempts threshold, set user lockout timer, and set the password-aging timer.
New commands also allow you to back up and restore the configuration in the shelf.
In order to use the security features, the hardware and firmware in the SSU-2000e
must be as shown in the following table.
The SSU-2000e system software allows you to set up a list of users with one of five
access levels; each level has an increasing level of access to system functions and
commands. Each incremental access level incorporates all of the options from the
lower numbered access levels and additional options at that level. For instance, a
User-level user does not have as many options available as a Technician-level user.
An Administrator-level user assigns the access level to each user when the user id
and password is created.
summarizes each access level, ID number, and
the operator privileges for each level.
Module
Module Part
Number
Hardware Revision
Required
1
Note:
1
The hardware revision is on a label located on the front panel. You can display the hardware
revision by issuing the TL1 command RTRV-INV, or the ICS command CONFIG.
Firmware Code Part
Number
Communications
module
23413012-00x-0
A.00 or higher
14313012-000-5 Rev. M.00
Clock modules
23413015-00x-0
23413016-000-0
A.00 or higher
A.00 or higher
14313015-000-5 Rev. M.00
Table 2-2. User Access Levels
Level
ID
Description
Idle
0
Access level 0 is available when no user is logged in. This level allows
Idle-level users to view a list of available commands (HELP), syntax, software
version number, unit id, or to login.
User
1
Users at the User level can execute level 0 commands and view information
about the current configuration and operation, and change communication
settings such as line termination and echo. Changes made by a User-level
user remain in effect only until the user logs out.
Technician
2
Users at the Technician level
(CRAFT persons) can perform levels 0 through 1
functions, and can read or set all installation functions.