12713140-003-2 Revision E.01 – January 2007
SSU-2000e Technical Reference 121
Chapter 2 TL1 Reference
Set CC Input Parameters
Set CC Input Parameters
This command sets the parameters on the specified Composite Clock Input module
or port.
Syntax
SET-PRMTR-CCINP:[tid]:[aid]:ctag::[pstate],[pri],[pql],[zs];
Related Commands
Parameter
Format
Description
aid
SxAy[-z]
Sets the parameters for the specfied CC Input module [or
port].
pstate
ON | OFF
Turns the selected module [or port] on or off.
pri
1 - 10 |
MON
Sets the priority of the specified module [or port]; MON =
Monitor.
pql
1 - 16
Sets the priority quality level of the specified module [or
port].
zs
ON | OFF
Turns zero suppression on or off for the specified module
[or port].