12713140-003-2 Revision E.01 – January 2007
SSU-2000e Technical Reference
43
Chapter 2 TL1 Reference
Retrieve CC Input Parameters
Retrieve CC Input Parameters
This command returns the settings for the Composite Clock Input module or port
designated by the aid.
Syntax
RTRV-PRMTR-CCINP:[tid]:[aid]:ctag;
Response Format
^^^"aid:pstate,pri,pql,mode,zs" <cr lf>
where:
aid
= module or port access identifier
pstate
= port enabled state [ON | OFF]
pri
= priority 1 (highest) through 10 (lowest) or MON for monitor
pql
= provisioned priority quality level [1 – 16]
mode
= CC, indicating Composite Clock
zs
= zero suppression [NA]
Related Commands
Parameter
Value
Description
[aid]
ALL
Retrieves the parameters from all CC Input modules in the
shelf.
S1Ay[-z]
Retrieves parameters from the specified CC Input module
[or port].