TL1 Command Interface
282
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
RTRV-DATA-PHASE:[tid]:aid:
ctag[::tmper[,clksrc[,start]
[,stop]]];
Valid aid code:
S1Ay-z
Returns phase data from phase history buffers. The
command requires an aid to identify the input to report data
from.
ctag
is followed by a null field
tmper
= optional parameter containing the averaging
time period for data to be returned: [100|1000|10000] with
the default of 100 if not specified
clksrc
= [CLK-A|CLK-B] or both (on separate message
lines) if not specified
The format for each response message line is:
^^^"aid:ocrdat,ocrtm,PHA,clksrc,tmper,(monval)"
<cr lf>
where:
ocrdat
and
ocrtm
are the actual date and time the data
was collected
clksrc
is [CLK-A|CLK-B] indicating the clock used for
the measurements
tmper
= time period of the measurement data, given as
xSEC where x
= time in seconds
monval
= +/- phase values versus clock for the specified
input given in nanoseconds enclosed in parentheses
start
= start time specifies the start date and time for
data in the format MM-DD,HH-MM. If the date is null but
followed by a time, the command defaults to the current
date. If the start time is null, but preceded by a date, the
command defaults to the current time. If the start date
and time are null, the command defaults to the start of the
data. The comma must be present to indicate a null start
time.
stop
= stop time specifies the stop date and time for data
in the format MM-DD,HH-MM. If the date is null but
followed by a time, the command defaults to the current
date. If the stop time is null but preceded by a date, the
command defaults to the current time. If the stop date and
time is null, the command defaults to the end of the data.
There is one line for each data point in the specified time
between start and stop times. Only the number of values
currently available is returned. The maximum stored points
for 100 second time period is 7000; the maximum stored
points for 1000 second time period is 700; the maximum
stored points for 10000 second time period is 70. If a start
and stop time is not specified, the default is current value.
Table B-5. TL1 Retrieve Commands (Continued)
Command
Description
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...