Clock Module Reference Data
Communications Module
140
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Alarm Levels
The Communications module alarm logic incorporates three alarm levels:
CRITICAL Alarms – This class of alarms requires immediate user intervention.
When a critical alarm condition is detected, the CRITICAL ALARM relay at the
rear panel of the SSU-2000 is activated and the CRITICAL ALARM LED on the
front of the Communications module lights red.
MAJOR Alarms – A class of alarms that may require immediate user intervention.
When a major alarm condition is detected, the major alarm relay on the rear
panel of the SSU-2000 is activated and the MAJOR ALARM LED on the front of
the Communications module lights red.
MINOR Alarms – A class of alarms that indicate the unit performance is
degrading. The minor relay is activated and the MINOR ALARM indicator lights.
Alarms are elevated from MINOR to MAJOR to CRITICAL on a per module basis
with a user-set time, from 60 to 500,000 seconds, default is (86,400 seconds or one
day). The elevation time is kept in each module.
The user can select delay periods for software alarms from 0 to 86400 seconds.
Changing the delay period generates an event. The setting is stored in each
module. Note: if the original value is set to IMMED (–1), it means this error delay is
not allowed to change and will happen immediately.
lists the Communications module alarms.
EIA-232 Ports
The Communications module implements four EIA-232 ports that provide for local
and remote communications with the SSU-2000.
A user interface (software resident in the Communications module) provides various
levels of password-protected access for configuration and detailed performance
monitoring and diagnostics. Use either the interactive command set or the TL1 user
interface for configuring and detailed performance monitoring, see
Table 6-8. Communications Module Alarms
ID
Description
Alarm
Level
Error Delay
Default
Error Delay
Settable?
0x0
Backplane Communication Errors
MINOR
5 sec
Yes
0x1
Mastership Problems
MINOR
5 sec
Yes
0x2
Loss of Power A
MINOR
Immed
No
0x3
Loss of Power B
MINOR
Immed
No
0x4
SPI Watchdog Timeout
MAJOR
Immed
No
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...