QUICK START GUIDE: 6100 Broadcast Audio Delay

Operations: Menu

6408 216th Street SW 

|

 Mountlake Terrace, WA 98043  USA

T

 +1.425.778.7728  

F

 +1.425.778.7727 

|

 

www.symetrix.co

MENU

OPTION

DESCRIPTION

SIGNAL INPUT SOURCE

ANALOG or AES/EBU

NOMINAL INPUT LEVEL

-10 dBu 
+0 dBu 
+4 dBu 
+8 dBu

NOMINAL OUTPUT LEVEL

-10 dBu 
+0 dBu 
+4 dBu 
+8 dBu

DIGITAL INPUT SYNC

INTERNAL 48KHZ 
WORD CLOCK 
AES/EBU

DELAY TIME

0.0 to 40.0 SECONDS 
(in 0.1 second increments)

DUMP LENGTH

FIFTH 
QUARTER 
THIRD 
HALF 
WHOLE

ALGORITHM

GAP DETECT

Waits for gaps or pauses in speech and then splices audio. Minimal delay artifacts.
Very fast delay build or exit times with speech only program when known maximum 
build and exit times are not required.

GAP DETECT & CATCH UP

If gaps do not naturally occur then splicing is forced. Some audible splice artifacts.
Use for building and exiting delay with music + speech when known maximum build 
and exit times are required.

CONTINUOUS

Continuously forces splicing regardless of program content. Some audible splice 
artifacts.
Use for building and exiting delay with music only when known maximum build and 
exit times are required.

PITCH SHIFT

Uses gradual, subtle pitch shifting instead of splicing to increase or decrease delay.
Use with music or music + speech when minimal artifacts are required. Build and exit 
times are predictable.

DELAY RATIO

10:1 to 40:1

Ratio controls the balance of delay build/exit speed vs. overall audio quality. 
(10:1 = fastest, 40:1 = best quality)

BARGRAPH MODE

PRE DELAY 

POST DELAY

AUTOMATION MODE

SWITCH CONTACTS DLYD 

RS232 DELAYED

Sets the automation delay mode for the unit. Either the contact closures on the  
AUTOMATION rear panel D-sub connector or the RS-232 connector may be 
delayed, not both. In RS-232 delay mode, any commands entering the unit on the 
RS-232 port will be delayed by the amount of current delay and then sent back 
out the RS-232 port. The RS-232 delay memory is limited to 500 characters at 
any one time. Data input beyond this limit will be silently discarded. If the device 
sending RS-232 automation data is different than the device receiving RS-232 
automation data, a custom cable may be required. Refer to the Wiring and Pinout 
section for details.

AUTOMATION TRIM

EARLY: 300 mS 
EARLY: 270 mS 
EARLY: 240 mS 
EARLY: 210 mS 
EARLY: 180 mS 
EARLY: 150 mS 
EARLY: 120 mS 

EARLY: 90 mS 
EARLY: 60 mS 
EARLY: 30 mS 

CURRENT DELAY 

LATE: 30 mS 
LATE: 60 mS 
LATE: 90 mS 

LATE: 120 mS 
LATE: 150 mS 
LATE: 180 mS 
LATE: 210 mS 
LATE: 240 mS 
LATE: 270 mS 
LATE: 300 mS

Adjusts the automation events to exit the delay early, on time, or late in relation to 
the audio. This trim is applied to RS-232 data or contact closures depending upon  
AUTOMATION MODE as set above.

TC89 OUTPUT DELAY

0.0 to 60.0 SECONDS 

(in 0.5 second increments)

Applies an additional fixed delay to the TC89 output so that certain constant 
system delays can be accounted for such as encoders or satellite transmission.

REAR SERIAL PORT

RS-232 (DB9) 

RS-485 (3 PIN EURO)

Select which communications interface to use.

SERIAL PORT BAUD

1200 
2400 
4800 
9600 

19200 
38400

Sets the baud rate for the selected serial port.

UNIT NUMBER

ID: (1-255)

Sets the RS-485 bus address.

Содержание 6100

Страница 1: ...ket outlet with a protective earthing connection Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacemen...

Страница 2: ...RGRAPH MODE PRE DELAY POST DELAY AUTOMATION MODE SWITCH CONTACTS DLYD RS232 DELAYED Sets the automation delay mode for the unit Either the contact closures on the AUTOMATION rear panel D sub connector or the RS 232 connector may be delayed not both In RS 232 delay mode any commands entering the unit on the RS 232 port will be delayed by the amount of current delay and then sent back out the RS 232...

Страница 3: ...e authorized representative located within the European Community is World Marketing Associates P O Box 100 St Austell Cornwall PL26 6YU U K Date of issue May 31 2009 Place of issue Mountlake Terrace Washington USA Authorized signature Dane Butcher President Symetrix Incorporated Remote Panel Switch Pinouts Function Pin START 1 EXIT 4 DUMP 7 COUGH 10 BYPASS Hardware 14 Switch Common 13 Automation ...

Страница 4: ...e intended to be run on a personal computer Said software is specifically excluded from this warranty Limitation of Liability The total liability of Symetrix on any claim whether in contract tort including negligence or otherwise arising out of connected with or resulting from the manufacture sale delivery resale repair replacement or use of any product will not exceed the price allocatable to the...

Отзывы: