27
Q u i c k R e f e r e n c e
Correcting Scale Problems
Problem
Possible Cause
Corrective Action
Error code 5----
displays
Scale drift
Verify that nothing is on the scale.
Lift the Top Plate and verify that no
objects are under it. Push Scale
Zero button. If error code persists,
have unit repaired.
Error code 4----
displays
Possible scale error Press Scale Zero button and retry. If
error code persists, have unit re-
paired.
Error code 4----
displays
Slight vibration to
scale when calibrat-
ing
Calibrate scale, not permitting any
external scale movement while the
weights are on the scale.
Scale display is
blank
Top Plate is being
prevented from
moving down.
Remove interference around edge
of Top Plate and checkstand.
Remove any foreign objects from
under the Top Plate.