8 - 8
Symbol MiniScan MSXX04 Series Integration Guide
Usable Scan Length
The decode zone is a function of various symbol characteristics including density, print contrast, wide-to-narrow
ratio, and edge accuracy. Consider the width of the scan line at any given distance when designing a system.
Calculating the Usable Scan Length Method (Symbol MS954 Only)on page 2-9
describes how to calculate the
usable scan length. The scan angle is provided in the usable scan length diagram on
Table 8-3
Symbol MS954 Decode Distances
Symbol Density/
p/n / Bar Code Type/
W-N Ratio
Bar Code Content/
Contrast
1
Typical Working Ranges
Guaranteed Working
Ranges
Near
Far
Near
Far
5 mil
64-17453-01
Code 39; 2.5:1
ABCDEFGH
90% MRD
0.7 in.
1.8 cm
7.3 in.
18.54 cm
1.6 in.
4.06 cm
4.8 in.
12.19 cm
7.5 mil
64-17452-01
Code 39; 2.5:1
ABCDEF
90% MRD
0.9 in.
2.29 cm
12.3 in.
31.24 cm
1.4 in.
3.56 cm
8.8 in.
22.35 cm
13 mil
64-05303-01
100% UPC
12345678905
90% MRD
0.9 in.
2.29 cm
22.0 in.
55.88 cm
1.1 in.
2.79 cm
15.7 in.
39.88 cm
20 mil
60-01429-01
Code 39; 2.2:1
123
90% MRD
Note 2
27.5 in.
69.85 cm
Note 2
22.0 in.
55.88 cm
40 mil
64-17457-01
Code 39; 2.2:1
AB
90% MRD
Note 2
28.0 in.
71.12 cm
Note 2
23.0 in.
58.42 cm
55 mil
64-17458-01
Code 39; 2.2:1
CD
90% MRD
Note 2
35.0 in.
88.90 cm
Note 2
29.0 in.
73.66 cm
Notes:
1. Contrast measured as Mean Reflective Difference (MRD) at 650 nm.
2. Near ranges on lower densities (not specified) largely depend on the width of the bar code and
the scan angle.
3. Working range specifications at ambient temperature (23°C), pitch=15°, roll=0°, skew=0°,
photographic quality, ambient light<200 ft-c.
Содержание MiniScan MS1204FZY
Страница 1: ...Symbol MiniScan MSXX04 Series Integration Guide...
Страница 2: ......
Страница 3: ...Symbol MiniScan MSXX04 Series Integration Guide 72E 67134 05 Revision A January 2008...
Страница 6: ...iv Symbol MiniScan MSXX04 Series Integration Guide...
Страница 14: ...xii Symbol MiniScan MSXX04 Series Integration Guide...
Страница 18: ...xvi Symbol MiniScan MSXX04 Series Integration Guide...
Страница 24: ...1 6 Symbol MiniScan MSXX04 Series Integration Guide...
Страница 42: ...2 18 Symbol MiniScan MSXX04 Series Integration Guide...
Страница 50: ...3 8 Symbol MiniScan MSXX04 Series Integration Guide...
Страница 70: ...5 12 Symbol MiniScan MSXX04 Series Integration Guide...
Страница 82: ...6 12 Symbol MiniScan MSXX04 Series Integration Guide...
Страница 94: ...7 12 Symbol MiniScan MSXX04 Series Integration Guide...
Страница 106: ...9 4 Symbol MiniScan MSXX04 Series Integration Guide...
Страница 218: ...10 112Symbol MiniScan MSXX04 Series Integration Guide Numeric Bar Codes continued 5 6 7 8 9...
Страница 219: ...Parameter Menus10 113 Cancel To change a selection or cancel an incorrect entry scan the bar code below Cancel...
Страница 220: ...10 114Symbol MiniScan MSXX04 Series Integration Guide...
Страница 240: ...A 16 Symbol MiniScan MSXX04 Series Integration Guide...
Страница 252: ...Glossary 12 Symbol MiniScan MSXX04 Series Integration Guide...
Страница 258: ......
Страница 259: ......