Страница 3: ...LS1203 Product Reference Guide 72E 73953 04 Revision A November 2012...

Страница 4: ...rogram in a network without written permission from Motorola The user agrees to maintain Motorola s copyright notice on the licensed programs delivered hereunder and to include the same on any authori...

Страница 5: ...Motorola rebranding add hands free stand assembly instructions add new UPC EAN supplemental options and Bookland ISBN format option 04 Rev A 8 2008 Add HD model change UCC EAN 128 code type name to G...

Страница 6: ...iv Symbol LS1203 Product Reference Guide...

Страница 7: ...tting Started Introduction 1 1 Unpacking 1 2 Setting Up the Scanner 1 2 Installing the Interface Cable 1 2 Removing the Interface Cable 1 3 Connecting Power if required 1 3 Assembling the Hands Free S...

Страница 8: ...e 4 7 Transmit Code ID Character 4 7 Prefix Suffix Values 4 8 Scan Data Transmission Format 4 8 FN1 Substitution Values 4 10 Transmit No Read Message 4 10 Chapter 5 Keyboard Wedge Interface Introducti...

Страница 9: ...for RS 232 6 17 Chapter 7 USB Interface Introduction 7 1 Connecting a USB Interface 7 2 USB Parameter Defaults 7 3 USB Host Parameters 7 4 USB Device Type 7 4 USB Country Keyboard Types Country Codes...

Страница 10: ...ert Code 39 to Code 32 8 21 Code 32 Prefix 8 21 Set Lengths for Code 39 8 22 Code 39 Check Digit Verification 8 23 Transmit Code 39 Check Digit 8 23 Code 39 Full ASCII Conversion 8 24 Code 39 Bufferin...

Страница 11: ...Redundancy Level 8 44 Security Level 8 46 Bi directional Redundancy 8 47 Symbology Intercharacter Gap 8 47 Chapter 9 123Scan Introduction 9 1 Communication with 123Scan2 9 1 123Scan2 Requirements 9 2...

Страница 12: ...x Symbol LS1203 Product Reference Guide Appendix E ASCII Character Sets Index...

Страница 13: ...per and LED definitions and how to use the scanner in triggered and Auto ScanTM modes Chapter 3 Maintenance Technical Specifications provides information on how to care for the scanner troubleshooting...

Страница 14: ...SCII character value tables Notational Conventions Italics are used to highlight chapters and sections in this and related documents Bold text is used to highlight the following Key names on a keypad...

Страница 15: ...torolasolutions com support When contacting Motorola Solutions support please have the following information available Serial number of the unit Model number or product name Software type and version...

Страница 16: ...xiv Symbol LS1203 Product Reference Guide...

Страница 17: ...ts scanned data as keystrokes This interface supports the following international keyboards for Windows environment North America German French French Canadian Spanish Italian Swedish UK English Portu...

Страница 18: ...ner and should be used if the equipment ever needs to be return for servicing Setting Up the Scanner Installing the Interface Cable To connect the interface cable 1 Insert the interface cable s modula...

Страница 19: ...nner an external power connection to the scanner is required To connect power 1 Connect the interface cable to the bottom of the scanner as described in Installing the Interface Cable on page 1 2 2 Co...

Страница 20: ...k piece fit into place in the stand base opening 3 Tighten the wingnut underneath the base to secure the cup and neck piece to the base 4 Bend the neck to the desired position for scanning Figure 1 4...

Страница 21: ...er off the exposed sides of each piece of tape and press the stand on a flat surface until it is secure Configuring the Scanner To configure the scanner use the bar codes included in this manual or th...

Страница 22: ...1 6 Symbol LS1203 Product Reference Guide...

Страница 23: ...ntroduction This chapter provides beeper and LED definitions techniques involved in scanning bar codes general instructions and tips about scanning and decode zone diagrams Figure 2 1 Parts LED Trigge...

Страница 24: ...amming refer to the Advanced Data Formatting Programmer Guide p n 72 69680 xx High high high low beeps RS 232 receive error Parameter Menu Scanning Short high beeps Correct entry scanned or correct me...

Страница 25: ...nly 4 short high beeps Scanner has not completed initialization Wait several seconds and scan again Scanner gives a power up beep after scanning a USB Device Type Communication with the bus must be es...

Страница 26: ...an line crosses every bar and space of the symbol Figure 2 3 Acceptable and Incorrect Aiming The scan line is smaller when the scanner is closer to the symbol and larger when it is farther from the sy...

Страница 27: ...ng 2 5 The scanner can be tilted up to 65 forward or back and achieve a successful decode Figure 2 4 Simple practice quickly shows what tolerances to work within Figure 2 4 Maximum Tilt Angles and Dea...

Страница 28: ...2 6 Symbol LS1203 Product Reference Guide Decode Zones LS1203 SR Standard Range Figure 2 5 LS1203 SR Standard Range Decode Zone...

Страница 29: ...at 73 F 23 C on high quality symbols in normal room light Minimum distance determined by symbol length and scan angle Depth of Field 5 mil 3 75 10 mil 6 63 20 mil 5 25 5 25 in cm 0 0 2 5 6 35 5 12 7 7...

Страница 30: ...2 8 Symbol LS1203 Product Reference Guide...

Страница 31: ...descriptions pinouts Maintenance Cleaning the exit window is the only maintenance required A dirty window may affect scanning ability Do not allow any abrasive material to touch the window Remove any...

Страница 32: ...The Code 39 buffer was erased or there was an attempt to clear or transmit an empty buffer Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 3...

Страница 33: ...o the host Scanner is not programmed for the correct host type Scan the appropriate host type programming bar code See the chapter corresponding to the host type Interface cable is loose Check for loo...

Страница 34: ...rsion Check the scanner s host type parameters or editing options Trigger Nothing happens when the trigger button is pressed No power to the scanner Check the system power If the configuration require...

Страница 35: ...int Contrast Minimum 30 minimum reflectance Decode Capability UPC EAN UPC EAN with Supplementals GS1 128 Code 39 Code 39 Full ASCII Code 39 TriOptic Code 128 Code 128 Full ASCII Codabar Interleaved 2...

Страница 36: ...Volume User selectable three levels Beeper Tone User selectable three tones Electrostatic Discharge Conforms to 15 kV air discharge and 8 kV of contact discharge Table 3 2 Technical Specifications Co...

Страница 37: ...r and are for reference only Table 3 3 Scanner Signal Pin outs Pin RS 232 Keyboard Wedge USB 1 Reserved Reserved Jump to Pin 6 2 Power Power Power 3 Ground Ground Ground 4 TxD KeyClock Reserved 5 RxD...

Страница 38: ...3 8 Symbol LS1203 Product Reference Guide...

Страница 39: ...when the scanner is powered down If not using a USB cable select a host type see each host chapter for specific host information after the power up beeps sound This is only necessary upon the first po...

Страница 40: ...4 3 NOTE See Appendix A Standard Defaults for all user preferences hosts and symbologies default parameters Table 4 1 User Preferences Parameter Default Page Number User Preferences Beeper Tone Medium...

Страница 41: ...tom default values were configured the factory default values are set for all parameters each time the Restore Defaults bar code below is scanned For factory default values see Appendix A Standard Def...

Страница 42: ...requency tone scan the Low Frequency Medium Frequency or High Frequency bar code Beeper Volume To select a beeper volume scan the Low Volume Medium Volume or High Volume bar code Low Frequency Medium...

Страница 43: ...the scanner trigger button must be pressed to decode each scanned bar code In Auto ScanTM scanning mode the scanner laser is in constant on state and no trigger button press is required to scan a bar...

Страница 44: ...Laser On Time is 3 0 seconds To set a Laser On Time scan the bar code below Next scan two numeric bar codes in Appendix D Numeric Bar Codes that correspond to the desired on time Single digit numbers...

Страница 45: ...e of a scanned bar code This may be useful when the scanner is decoding more than one code type In addition to any single character prefix already selected the Code ID character is inserted between th...

Страница 46: ...sion Format To change the scan data format scan Scan Options and one of the following four bar codes corresponding to the desired format Data As Is DATA SUFFIX PREFIX DATA PREFIX DATA SUFFIX Scan Ente...

Страница 47: ...User Preferences 4 9 Scan Data Transmission Format continued Scan Options Data As Is DATA SUFFIX PREFIX DATA PREFIX DATA SUFFIX Enter Data Format Cancel...

Страница 48: ...ed host interface 3 Enter the 4 digit substitution value by scanning each digit in Appendix D Numeric Bar Codes To correct an error or change the selection scan Cancel To enable FN1 substitution for k...

Страница 49: ...mputer and translates bar code data into keystrokes The host computer accepts the keystrokes as if they originated from the keyboard This mode adds bar code reading functionality to a system designed...

Страница 50: ...ard connector of the Y cable to the keyboard connector 5 If needed attach the optional power supply to the connector in the middle of the Y cable 6 Ensure that all connections are secure 7 Turn on the...

Страница 51: ...ults Parameter Default Page Number Keyboard Wedge Host Parameters Keyboard Wedge Host Type IBM PC AT IBM PC Compatibles1 5 4 Country Types Country Codes North American 5 5 Ignore Unknown Characters Se...

Страница 52: ...rs Keyboard Wedge Host Types Select the Keyboard Wedge host by scanning one of the bar codes below IBM PC AT IBM PC Compatibles1 IBM AT Notebook NCR 7052 IBM PS 2 Model 30 NOTE 1User selection is requ...

Страница 53: ...n the bar code corresponding to the keyboard type If the keyboard type is not listed see Alternate Numeric Keypad Emulation on page 5 8 North American German Windows French Windows French Canadian Win...

Страница 54: ...unknown characters and no error beeps sound on the scanner When Do Not Send Bar Codes With Unknown Characters is selected bar code data is sent up to the first unknown character then the scanner issu...

Страница 55: ...lay when hosts require a slower transmission of data Intra Keystroke Delay When enabled an additional delay is inserted between each emulated key depression and release This sets the Keystroke Delay p...

Страница 56: ...Country Codes on page 5 5 in a Microsoft operating system environment Caps Lock On When enabled the scanner emulates keystrokes as if the Caps Lock key is always pressed Note that if both Caps Lock O...

Страница 57: ...s sent as an A no matter what the state of the keyboard s Caps Lock key Convert Wedge Data When enabled the scanner will convert all bar code data to the selected case NOTE If both Caps Lock On and Ca...

Страница 58: ...t in place of the standard key mapping Table entries that do not have a bold entry remain the same whether or not this parameter is enabled FN1 Substitution When enabled the scanner replaces FN1 chara...

Страница 59: ...llowing keyboard maps are provided for prefix suffix keystroke parameters To program the prefix suffix values see the bar codes on page 4 8 Figure 5 2 IBM PC AT Figure 5 3 IBM PS 2 Send Make and Break...

Страница 60: ...lent of ABC Table 5 2 Keyboard Wedge ASCII Character Set ASCII Value Full ASCII Code 39 Encode Character Keystroke 1001 A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1...

Страница 61: ...Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O 1048 0 0 1049 1 1 1050 2 2 Table 5 2 Keyboard Wedge ASCII Character Set Continued ASCII Value...

Страница 62: ...1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N Table 5 2 Keyboard Wedge ASCII Character Set Continued ASCII Value Full AS...

Страница 63: ...L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j Table 5 2 Keyboard Wedge ASCII Character Set Continued ASCII Value Full ASCII...

Страница 64: ...123 P 1124 Q 1125 R 1126 S Table 5 3 Keyboard Wedge ALT Key Character Set ALT Keys Keystroke 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F Table 5 2 Keyboard Wedge ASCII Character...

Страница 65: ...LT Q 2082 ALT R 2083 ALT S 2084 ALT T 2085 ALT U 2086 ALT V 2087 ALT W 2088 ALT X 2089 ALT Y 2090 ALT Z Table 5 4 Keyboard Wedge GIU Key Character Set GUI Keys Keystrokes 3000 Right Control Key 3048 G...

Страница 66: ...3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P 3081 GUI Q 3082 GUI R 3083 GUI S 3084 GUI T 3085 GUI U 3086 GUI V 3...

Страница 67: ...Wedge F Key Character Set F Keys Keystroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 5016 F16 5017 F17 5018 F18 5019...

Страница 68: ...eference Guide Table 5 6 Keyboard Wedge Numeric Keypad Character Set Numeric Keypad Keystroke 6042 6043 6044 undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 605...

Страница 69: ...Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 70...

Страница 70: ...5 22 Symbol LS1203 Product Reference Guide...

Страница 71: ...2 refer to the documentation for the host device to set communication parameters to match the host Throughout the programming bar code menus default values are indicated with asterisks NOTE The scann...

Страница 72: ...ost 3 Connect the power supply to the serial connector end of the RS 232 interface cable Plug the power supply into an appropriate outlet 4 Select the RS 232 host type by scanning the appropriate bar...

Страница 73: ...lt parameters Table 6 1 RS 232 Defaults Parameter Default Page Number RS 232 Host Parameters RS 232 Host Types Standard 6 6 Baud Rate 9600 6 7 Parity Type None 6 8 Stop Bit Select 1 Stop Bit 6 9 Data...

Страница 74: ...Suffix Data Suffix Data Suffix Data Suffix Prefix Data Suffix Data Suffix Suffix CR LF 7013 CR 1013 CR 1013 CR 1013 CR 1013 ETX 1002 CR 1013 Baud Rate 9600 9600 9600 9600 9600 9600 9600 Parity None E...

Страница 75: ...ode 39 C len None M M M len C len Codabar N len None N N N len N len Code 128 L len None K K K len L len I 2 of 5 I len None I I I len I len Code 93 None None L L L len None D 2 of 5 H len None H H H...

Страница 76: ...nce Guide RS 232 Host Types To select an RS 232 host interface scan one of the following bar codes Standard RS 232 ICL RS 232 Wincor Nixdorf RS 232 Mode A Wincor Nixdorf RS 232 Mode B Olivetti ORS4500...

Страница 77: ...ted per second Set the scanner s baud rate to match the baud rate setting of the host device Otherwise data may not reach the host device or may reach it in distorted form Baud Rate 600 Baud Rate 1200...

Страница 78: ...is set to 0 or 1 based on data to ensure that an odd number of 1 bits are contained in the coded character Select Even parity and the parity bit value is set to 0 or 1 based on data to ensure that an...

Страница 79: ...next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is programmed to accommodate Set the number of stop bits to match hos...

Страница 80: ...lost When the CTS line is de asserted the scanner asserts the RTS line and waits up to Host Serial Response Time out for the host to assert CTS When the host asserts CTS data is transmitted If after...

Страница 81: ...w user programmed logic level However the scanner waits for CTS to be asserted before transmitting data If CTS is not asserted within Host Serial Response Time out the scanner issues an error indicati...

Страница 82: ...ies when a time out occurs ENQ When this option is selected the scanner waits for an ENQ character from the host before transmitting data If an ENQ is not received within the Host Serial Response Time...

Страница 83: ...t Serial Response Time out This parameter specifies how long the scanner waits for an ACK NAK ENQ XON or CTS before determining that a transmission error occurred ACK NAK with ENQ XON XOFF Minimum 2 S...

Страница 84: ...select Low RTS or High RTS line state Beep on BEL When this parameter is enabled the scanner issues a beep when a BEL character is detected on the RS 232 serial line BEL is issued to gain a user s at...

Страница 85: ...232 Interface 6 15 Intercharacter Delay This parameter specifies the intercharacter delay inserted between character transmissions Minimum 0 msec Low 25 msec Medium 50 msec High 75 msec Maximum 99 ms...

Страница 86: ...s with Unknown Characters is selected all bar code data is sent except for unknown characters and no error beeps sound on the scanner When Do Not Send Bar Codes With Unknown Characters is selected bar...

Страница 87: ...S 232 ASCII Value Full ASCII Code 39 Encode Character ASCII Character 1000 U NUL 1001 A SOH 1002 B STX 1003 C ETX 1004 D EOT 1005 E ENQ 1006 F ACK 1007 G BELL 1008 H BCKSPC 1009 I HORIZ TAB 1010 J LF...

Страница 88: ...Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 1053 5 5 1054 6 6 1057 7 7 1056 8 8 Table 6 4 A...

Страница 89: ...B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P 1081 Q Q 1082 R R 1083 S S 1084 T T 1085 U U 1086 V V Table 6 4 ASCII Ch...

Страница 90: ...95 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l 1109 M m 1110 N n 1111 O o 1112 P p 1113 Q q 1114 R r 1115 S s 1116 T t Table...

Страница 91: ...1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S 1127 Undefined 7013 ENTER Table 6 4 ASCII Character Set for RS 232 Continued ASCII Value Full ASCII Code 39 Encode Cha...

Страница 92: ...6 22 Symbol LS1203 Product Reference Guide...

Страница 93: ...to a USB host The scanner attaches directly to a USB host or a powered USB hub and is powered by it No additional power supply is required Throughout the programming bar code menus default values are...

Страница 94: ...han one keyboard The following operating systems support the scanner through USB Windows 98 2000 ME XP MacOS 8 5 and above IBM 4690 OS The scanner will also interface with other USB hosts which suppor...

Страница 95: ...any other parameter options scan the appropriate bar codes in this chapter If problems occur with the system see Troubleshooting on page 3 2 USB Parameter Defaults Table 7 1 lists the defaults for USB...

Страница 96: ...ers USB Device Type Select the desired USB device type NOTE When changing USB Device Types the scanner automatically restarts The scanner issues the standard startup beep sequences HID Keyboard Emulat...

Страница 97: ...ies only to the USB HID Keyboard Emulation device NOTE When changing USB country keyboard types the scanner automatically resets The scanner issues the standard startup beep sequences North American S...

Страница 98: ...7 6 Symbol LS1203 Product Reference Guide USB Country Keyboard Types Country Codes continued Italian Windows Swedish Windows UK English Windows Japanese Windows ASCII Portuguese Brazilian Windows...

Страница 99: ...data USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device When enabled the case of the data is preserved regardless of the state of the caps lock key This setting is a...

Страница 100: ...t for unknown characters and no error beeps sound When Do Not Send Bar Codes With Unknown Characters is selected bar code data is sent up to the first unknown character then the scanner issues an erro...

Страница 101: ...ues on page 4 10 to set the Key Category and Key Value Function Key Mapping ASCII values under 32 are normally sent as a control key sequences see Table 7 2 on page 7 11 When this parameter is enabled...

Страница 102: ...s if the Caps Lock state is enabled on the keyboard This inversion is done regardless of the current state of the keyboard s Caps Lock state Convert Case When enabled the scanner will convert all bar...

Страница 103: ...RL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M CTRL M ENTER1 1014 N CTRL N 1015 O CTRL O 1016 P CTRL P 1017 Q...

Страница 104: ...1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K 1044 L 1045 1046 1047 O 1048 0 0 1049 1 1 1050 2 2 1051 3 3 1052 4 4 Table 7 2 ASCII Character Set for USB Continued ASCII Value F...

Страница 105: ...1068 D D 1069 E E 1070 F F 1071 G G 1072 H H 1073 I I 1074 J J 1075 K K 1076 L L 1077 M M 1078 N N 1079 O O 1080 P P Table 7 2 ASCII Character Set for USB Continued ASCII Value Full ASCII Code 39 Enc...

Страница 106: ...1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c 1100 D d 1101 E e 1102 F f 1103 G g 1104 H h 1105 I i 1106 J j 1107 K k 1108 L l Table 7 2 ASCII Character Set for USB Continued ASCII Value Full ASC...

Страница 107: ...u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q 1125 R 1126 S Table 7 2 ASCII Character Set for USB Continued ASCII Value Full ASCII Code 39 Encode Character Keystroke 1 The keystroke in...

Страница 108: ...2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 2...

Страница 109: ...I 8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P Note GUI...

Страница 110: ...stroke 5001 F1 5002 F2 5003 F3 5004 F4 5005 F5 5006 F6 5007 F7 5008 F8 5009 F9 5010 F10 5011 F11 5012 F12 5013 F13 5014 F14 5015 F15 Table 7 4 USB GUI Key Character Set Continued GUI Key Keystroke Not...

Страница 111: ...5023 F23 5024 F24 Table 7 6 USB Numeric Keypad Character Set Numeric Keypad Keystroke 6042 6043 6044 undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058...

Страница 112: ...Character Set Extended Keypad Keystroke 7001 Break 7002 Delete 7003 PgUp 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter 701...

Страница 113: ...ter for specific host information after the power up beeps sound This is only necessary upon the first power up when connected to a new host To return all features to default values scan the appropria...

Страница 114: ...y Defaults Parameter Default Page Number UPC EAN UPC A Enable 8 5 UPC E Enable 8 5 UPC E1 Disable 8 6 EAN 8 JAN 8 Enable 8 7 EAN 13 JAN 13 Enable 8 7 Bookland EAN Disable 8 7 Decode UPC EAN JAN Supple...

Страница 115: ...le 8 23 Code 39 Full ASCII Conversion Disable 8 24 Buffer Code 39 Disable 8 24 Code 93 Code 93 Disable 8 27 Set Length s for Code 93 4 to 55 8 27 Code 11 Code 11 Disable 8 28 Set Lengths for Code 11 4...

Страница 116: ...39 Set Length s for MSI 2 to 55 8 39 MSI Check Digits One 8 40 Transmit MSI Check Digit Disable 8 41 MSI Check Digit Algorithm Mod 10 Mod 10 8 41 GS1 DataBar formerly RSS Reduced Space Symbology GS1...

Страница 117: ...Symbologies 8 5 UPC EAN Enable Disable UPC A UPC E To enable or disable UPC A or UPC E scan the appropriate bar code below Enable UPC A Disable UPC A Enable UPC E Disable UPC E...

Страница 118: ...Reference Guide Enable Disable UPC E1 UPC E1 is disabled by default To enable or disable UPC E1 scan the appropriate bar code below NOTE UPC E1 is not a UCC Uniform Code Council approved symbology Ena...

Страница 119: ...N scan the appropriate bar code below Enable EAN 13 Disable EAN 13 Enable EAN 8 Disable EAN 8 Enable Bookland EAN Disable Bookland EAN NOTE If you enable Bookland EAN select a Bookland ISBN Format on...

Страница 120: ...nfirm that there is no supplemental The scanner transmits UPC EAN bar codes that do not have that prefix immediately Enable 378 379 Supplemental Mode Enable 978 979 Supplemental Mode Enable 977 Supple...

Страница 121: ...entals continued Decode UPC EAN JAN Only With Supplementals 01h Ignore Supplementals 00h Autodiscriminate UPC EAN JAN Supplementals 02h Enable 378 379 Supplemental Mode 04h Enable 978 979 Supplemental...

Страница 122: ...4 419 434 439 Supplemental Mode 06h Enable 491 Supplemental Mode 08h Enable Smart Supplemental Mode 03h Supplemental User Programmable Type 1 09h Supplemental User Programmable Type 1 and 2 0Ah Smart...

Страница 123: ...scriminate UPC EAN JAN Supplementals selected this option adjusts the number of times a symbol without supplementals is decoded before transmission The range is from two to thirty times Five or above...

Страница 124: ...It is always verified to guarantee the integrity of the data Transmit UPC E Check Digit The check digit is the last character of the symbol used to verify the integrity of the data Scan the appropriat...

Страница 125: ...le Preamble characters are part of the UPC symbol consisting of Country Code and System Character Three options are given for transmitting UPC A preamble to the host device transmit System Character o...

Страница 126: ...hree options are given for transmitting UPC E preamble to the host device transmit System Character only transmit System Character and Country Code 0 for USA and no preamble transmitted Scan a bar cod...

Страница 127: ...ow to match the host system Convert UPC E to UPC A Enable this to convert UPC E zero suppressed decoded data to UPC A format before transmission After conversion the data follows UPC A format and is a...

Страница 128: ...ions e g Preamble Check Digit When disabled UPC E1 decoded data is transmitted as UPC E1 data without conversion EAN 8 JAN 8 Extend When enabled this parameter adds five leading zeros to decoded EAN 8...

Страница 129: ...a starting with 979 is not considered Bookland in this mode Bookland ISBN 13 The scanner reports Bookland data starting with either 978 or 979 as EAN 13 in 13 digit format to meet the 2007 ISBN 13 pro...

Страница 130: ...es UPCA EAN 13 and EAN 128 must be enabled to scan all types of Coupon Codes Code 128 Enable Disable Code 128 To enable or disable Code 128 scan the appropriate bar code below Enable UCC Coupon Extend...

Страница 131: ...iate bar code below Enable Disable ISBT 128 ISBT 128 is a variant of Code 128 used in the blood bank industry Scan the appropriate bar code below to enable or disable ISBT 128 If necessary the host mu...

Страница 132: ...ioptic Code 39 is a variant of Code 39 used in the marking of computer tape cartridges Trioptic Code 39 symbols always contain six characters To enable or disable Trioptic Code 39 scan the appropriate...

Страница 133: ...39 to Code 32 Code 32 Prefix Scan the appropriate bar code below to enable or disable adding the prefix character A to all Code 32 bar codes NOTE Code 39 must be enabled for this parameter to function...

Страница 134: ...ing the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only those Code 39 symbols containing either 2 or 14 characters select Code 39 Two Discrete Lengths then scan 0 2 1 and...

Страница 135: ...lo 43 check digit are decoded Enable this feature if the Code 39 symbols contain a Modulo 43 check digit Transmit Code 39 Check Digit Scan the appropriate bar code below to transmit Code 39 data with...

Страница 136: ...ol with no leading space causes transmission in sequence of all buffered data in a first in first out format plus transmission of the triggering symbol See the following pages for further details When...

Страница 137: ...d and a Code 39 symbol must be read with a space immediately following the start pattern Unless the data overflows the transmission buffer the scanner issues a low high beep to indicate successful dec...

Страница 138: ...ssion Buffer The Code 39 buffer holds 200 characters If the symbol just read results in an overflow of the transmission buffer The scanner indicates that the symbol was rejected by issuing three long...

Страница 139: ...option to decode only Code 93 symbols containing either of two selected lengths Select lengths using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only those Code 93 sym...

Страница 140: ...Lengths for Code 93 continued Code 11 Code 11 To enable or disable Code 11 scan the appropriate bar code below Code 93 One Discrete Length Code 93 Two Discrete Lengths Code 93 Length Within Range Cod...

Страница 141: ...elect lengths using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only those Code 11 symbols containing either 2 or 14 characters select Code 11 Two Discrete Lengths then...

Страница 142: ...to check for one check digit check for two check digits or disable the feature To enable this feature scan the bar code below corresponding to the number of check digits encoded in your Code 11 symbol...

Страница 143: ...r codes in Appendix D Numeric Bar Codes For example to decode only those I 2 of 5 symbols containing either 2 or 14 characters select I 2 of 5 Two Discrete Lengths then scan 0 2 1 and then 4 To correc...

Страница 144: ...8 32 Symbol LS1203 Product Reference Guide Set Lengths for Interleaved 2 of 5 continued I 2 of 5 One Discrete Length I 2 of 5 Two Discrete Lengths I 2 of 5 Length Within Range I 2 of 5 Any Length...

Страница 145: ...h either the specified Uniform Symbology Specification USS or the Optical Product Code Council OPCC check digit algorithm Transmit I 2 of 5 Check Digit Scan the appropriate bar code below to transmit...

Страница 146: ...13 To accomplish this the I 2 of 5 code must be enabled and the code must have a leading zero and a valid EAN 13 check digit Discrete 2 of 5 DTF Enable Disable Discrete 2 of 5 To enable or disable Di...

Страница 147: ...select D 2 of 5 Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Cancel on page D 3 Length Within Range Select this option to decode a D 2 of 5 symbo...

Страница 148: ...able Chinese 2 of 5 To enable or disable Chinese 2 of 5 scan the appropriate bar code below Codabar NW 7 Enable Disable Codabar To enable or disable Codabar scan the appropriate bar code below Enable...

Страница 149: ...s Select lengths using the numeric bar codes in Appendix D Numeric Bar Codes For example to decode only Codabar symbols containing either 2 or 14 characters select Codabar Two Discrete Lengths then sc...

Страница 150: ...Codabar symbol Enable this feature if your host system requires this data format NOTIS Editing When enabled this parameter strips the start and stop characters from a decoded Codabar symbol Enable thi...

Страница 151: ...des For example to decode only MSI symbols containing either 2 or 14 characters select MSI Two Discrete Lengths then scan 0 2 1 and then 4 To correct an error or to change the selection scan Cancel on...

Страница 152: ...cond check digit is optional If the MSI codes include two check digits scan the Two MSI Check Digits bar code to enable verification of the second check digit See MSI Check Digit Algorithm on page 8 4...

Страница 153: ...t the check digit MSI Check Digit Algorithm Two algorithms are possible for the verification of the second MSI check digit Select the bar code below corresponding to the algorithm used to encode your...

Страница 154: ...taBar Expanded and GS1 DataBar Limited GS1 DataBar 14 and GS1 DataBar Expanded include stacked versions Scan the appropriate bar code below to enable or disable each variant of GS1 DataBar Enable GS1...

Страница 155: ...single zero as the first digit and report the bar code as EAN 13 For bar codes beginning with two or more zeros but not six zeros this parameter strips the leading 0100 and reports the bar code as UPC...

Страница 156: ...Level 2 The following code types must be successfully read twice before being decoded Redundancy Level 3 Code types other than the following must be successfully read twice before being decoded The f...

Страница 157: ...4 The following code types must be successfully read three times before being decoded Table 8 5 Redundancy Level 4 Code Types Code Type Code Length All All Redundancy Level 1 Redundancy Level 2 Redun...

Страница 158: ...providing sufficient security in decoding most in spec bar codes Security Level 1 Select this option if misdecodes occur This security level should eliminate most misdecodes Security Level 2 Select t...

Страница 159: ...ap The Code 39 and Codabar symbologies have an intercharacter gap that is customarily quite small Due to various bar code printing technologies this gap may grow larger than the maximum size allowed c...

Страница 160: ...8 48 Symbol LS1203 Product Reference Guide...

Страница 161: ...port options include programmed parameters asset tracking information and proof of scanner output Additionally 123Scan can display scanned bar code data including non printable characters It can displ...

Страница 162: ...ss scanning only USB cable For more information on 123Scan go to http www motorolasolutions com 123Scan For a one minute tour of 123Scan go to http www motorolasolutions com scannerhowtovideos To down...

Страница 163: ...tured application with image and data capture as well as asset management these tools help you every step of the way To download any of the free tools listed below go to www MotorolaSolutions com Scan...

Страница 164: ...9 4 Symbol LS1203 Product Reference Guide...

Страница 165: ...123Scan 9 5...

Страница 166: ...9 6 Symbol LS1203 Product Reference Guide...

Страница 167: ...ood Decode Enable 4 7 Transmit Code ID Character None 4 7 Prefix Value 7013 CR LF 4 8 Suffix Value 7013 CR LF 4 8 Scan Data Transmission Format Data As Is 4 8 FN1 Substitution Values Set 4 10 Transmit...

Страница 168: ...8 Bit 6 9 Check Receive Errors Enable 6 10 Hardware Handshaking None 6 10 Software Handshaking None 6 12 Host Serial Response Time out 2 Sec 6 13 RTS Line State Low RTS 6 14 Beep on BEL Disable 6 14...

Страница 169: ...Supplementals 8 11 Decode UPC EAN JAN Supplemental Redundancy 7 8 11 Transmit UPC A Check Digit Enable 8 12 Transmit UPC E Check Digit Enable 8 12 Transmit UPC E1 Check Digit Enable 8 13 UPC A Preambl...

Страница 170: ...Disable 8 24 Buffer Code 39 Disable 8 24 Code 93 Code 93 Disable 8 27 Set Length s for Code 93 4 to 55 8 27 Code 11 Code 11 Disable 8 28 Set Lengths for Code 11 4 to 55 8 29 Code 11 Check Digit Verif...

Страница 171: ...Disable 8 41 MSI Check Digit Algorithm Mod 10 Mod 10 8 41 GS1 DataBar formerly RSS Reduced Space Symbology GS1 DataBar 14 Disable 8 42 GS1 DataBar Limited Disable 8 42 GS1 DataBar Expanded Disable 8 4...

Страница 172: ...de Character Code Type A UPC A UPC E UPC E1 EAN 8 EAN 13 B Code 39 Code 39 Full ASCII Code 32 C Codabar D Code 128 ISBT 128 E Code 93 F Interleaved 2 of 5 G Discrete 2 of 5 or Discrete 2 of 5 IATA H C...

Страница 173: ...ataBar Family F Codabar G Code 93 H Code 11 I Interleaved 2 of 5 M MSI S D2 of 5 IATA 2 of 5 X Bookland EAN Trioptic Code 39 Table B 3 Modifier Characters Code Type Option Value Option Code 39 0 No ch...

Страница 174: ...der has checked check digit 3 Reader has stripped check digit before transmission Example A Codabar bar code without check digit 4123 is transmitted as F04123 Code 93 0 No options specified at this ti...

Страница 175: ...ers validated but not transmitted GS1 DataBar Family No option specified at this time Always transmit 0 GS1 DataBar 14 and GS1 DataBar Limited transmit with an Application Identifier 01 Note In GS1 12...

Страница 176: ...Appendix C Sample Bar Codes Code 39 UPC EAN UPC A 100 EAN 13 100 123ABC 0 12345 67890 5 3 456789 012340...

Страница 177: ...Sample Bar Codes C 2 Code 128 Interleaved 2 of 5 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 12345678901231...

Страница 178: ...r variants must be enabled to read the bar codes below see GS1 DataBar formerly RSS Reduced Space Symbology on page 8 42 10293847560192837465019283746029478450366523 GS1 DataBar Expanded Stacked 12348...

Страница 179: ...Sample Bar Codes C 4 GS1 DataBar 14 55432198673467 GS1 DataBar 14 Truncated 90876523412674 GS1 DataBar 14 Stacked 78123465709811 GS1 DataBar 14 Stacked Omni Directional...

Страница 180: ...C 5 Symbol LS1203 Product Reference Guide...

Страница 181: ...Appendix D Numeric Bar Codes Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1 2 3...

Страница 182: ...D 2 Symbol LS1203 Product Reference Guide Numeric Bar Codes continued 4 5 6 7 8 9...

Страница 183: ...Numeric Bar Codes D 3 Cancel To correct an error or change a selection scan the bar code below Cancel...

Страница 184: ...D 4 Symbol LS1203 Product Reference Guide...

Страница 185: ...A CTRL A 1002 B CTRL B 1003 C CTRL C 1004 D CTRL D 1005 E CTRL E 1006 F CTRL F 1007 G CTRL G 1008 H CTRL H BACKSPACE1 1009 I CTRL I HORIZONTAL TAB1 1010 J CTRL J 1011 K CTRL K 1012 L CTRL L 1013 M CT...

Страница 186: ...RL Z 1027 A CTRL 1028 B CTRL 1029 C CTRL 1030 D CTRL 6 1031 E CTRL 1032 Space Space 1033 A 1034 B 1035 C 1036 D 1037 E 1038 F 1039 G 1040 H 1041 I 1042 J 1043 K Table E 1 ASCII Value Code 39 Encode Ke...

Страница 187: ...058 Z 1059 F 1060 G 1061 H 1062 I 1063 J 1064 V 1065 A A 1066 B B 1067 C C 1068 D D 1069 E E 1070 F F 1071 G G Table E 1 ASCII Value Code 39 Encode Keystroke Continued ASCII Value Full ASCII Code 39 E...

Страница 188: ...T 1085 U U 1086 V V 1087 W W 1088 X X 1089 Y Y 1090 Z Z 1091 K 1092 L 1093 M 1094 N 1095 O _ 1096 W 1097 A a 1098 B b 1099 C c Table E 1 ASCII Value Code 39 Encode Keystroke Continued ASCII Value Full...

Страница 189: ...Q q 1114 R r 1115 S s 1116 T t 1117 U u 1118 V v 1119 W w 1120 X x 1121 Y y 1122 Z z 1123 P 1124 Q I 1125 R 1126 S Table E 1 ASCII Value Code 39 Encode Keystroke Continued ASCII Value Full ASCII Code...

Страница 190: ...2064 ALT 2 2065 ALT A 2066 ALT B 2067 ALT C 2068 ALT D 2069 ALT E 2070 ALT F 2071 ALT G 2072 ALT H 2073 ALT I 2074 ALT J 2075 ALT K 2076 ALT L 2077 ALT M 2078 ALT N 2079 ALT O 2080 ALT P 2081 ALT Q 20...

Страница 191: ...Miscellaneous Key Standard Defaults Misc Key Keystroke 3001 PA 1 3002 PA 2 3003 CMD 1 3004 CMD 2 3005 CMD 3 3006 CMD 4 3007 CMD 5 3008 CMD 6 3009 CMD 7 3010 CMD 8 3011 CMD 9 3012 CMD 10 3013 CMD 11 3...

Страница 192: ...8 3057 GUI 9 3065 GUI A 3066 GUI B 3067 GUI C 3068 GUI D 3069 GUI E 3070 GUI F 3071 GUI G 3072 GUI H 3073 GUI I 3074 GUI J 3075 GUI K 3076 GUI L 3077 GUI M 3078 GUI N 3079 GUI O 3080 GUI P GUI Shift...

Страница 193: ...oke 4001 PF 1 4002 PF 2 4003 PF 3 4004 PF 4 4005 PF 5 4006 PF 6 4007 PF 7 4008 PF 8 4009 PF 9 4010 PF 10 4011 PF 11 4012 PF 12 4013 PF 13 Table E 4 GUI Shift Keys Continued Other Value Keystroke GUI S...

Страница 194: ...Default Table F Keys Keystroke 5001 F 1 5002 F 2 5003 F 3 5004 F 4 5005 F 5 5006 F 6 5007 F 7 5008 F 8 5009 F 9 5010 F 10 5011 F 11 5012 F 12 5013 F 13 5014 F 14 5015 F 15 5016 F 16 5017 F 17 5018 F...

Страница 195: ...7 Numeric Key Standard Default Table Numeric Keypad Keystroke 6042 6043 6044 Undefined 6045 6046 6047 6048 0 6049 1 6050 2 6051 3 6052 4 6053 5 6054 6 6055 7 6056 8 6057 9 6058 Enter 6059 Num Lock Ta...

Страница 196: ...ard Default Table Extended Keypad Keystroke 7001 Break 7002 Delete 7003 Pg Up 7004 End 7005 Pg Dn 7006 Pause 7007 Scroll Lock 7008 Backspace 7009 Tab 7010 Print Screen 7011 Insert 7012 Home 7013 Enter...

Страница 197: ...ode 4 5 prefix suffix values 4 8 RS 232 baud rate 6 7 beep on 6 14 check receive errors 6 10 data bits 6 9 hardware handshaking 6 10 host serial response time out 6 13 host types 6 6 ignore unknown ch...

Страница 198: ...ndancy 8 11 UPC A preamble 8 13 UPC A transmit check digit 8 12 UPC A UPC E enable disable 8 5 UPC E preamble 8 14 UPC E transmit check digit 8 12 UPC E1 preamble 8 15 UPC E1 transmit check digit 8 13...

Страница 199: ...efaults 4 3 symbologies 8 2 transmit code ID character 4 7 transmit no read message 4 10 USB 7 4 parts 2 1 2 4 pinouts scanner signal descriptions 3 6 power supply connecting 1 3 R RS 232 connection 6...

Страница 200: ...USB parameters 7 4 user preferences bar codes beep after good decode 4 7 beeper tone 4 4 beeper volume 4 4 FN1 sub values 4 10 laser on time 4 6 power mode 4 5 prefix suffix values 4 8 scan data tran...