Enable/Disable Code 39 Full ASCII (Cont’d)

ENABLE CODE 39 FULL ASCII

DISABLE CODE 39 FULL ASCII

Содержание LS 6000i

Страница 1: ...Product Reference Guide LS 6000i Series...

Страница 2: ...LS 6000i Series Product Reference Guide 72 51596 01 Revision A July 2001...

Страница 3: ...k from a licensed program or use a licensed program in a network without written permission from Symbol The user agrees to maintain Symbol s copyright notice on the licensed programs delivered hereund...

Страница 4: ...ervice Information xi Symbol Support Center xii Warranty xvi Warranty Coverage and Procedure xvii General xviii Chapter 1 Introduction Overview 1 1 Using Your Scanner 1 3 Chapter 2 Setup Unpacking 2 1...

Страница 5: ...Your Scanner 4 1 Scan Zone 4 2 Technical Specifications 4 3 Troubleshooting 4 5 Chapter 5 Programming Operational Parameters 5 1 Defaults 5 2 Set Default Parameter 5 10 Host Type 5 11 IBM 46XX Host Ty...

Страница 6: ...nd EAN 5 75 Decode UPC EAN Supplementals 5 76 Decode UPC EAN Supplemental Redundancy 5 78 Transmit UPC A Check Digit 5 79 Transmit UPC E Check Digit 5 80 Random Weight Check Digit 5 81 UPC A Preamble...

Страница 7: ...s for Interleaved 2 of 5 5 113 I 2 of 5 Check Digit Verification 5 116 Transmit I 2 of 5 Check Digit 5 118 Convert I 2 of 5 to EAN 13 5 119 Codabar Options 5 120 Enable Disable Codabar 5 120 Set Lengt...

Страница 8: ...vii Contents Modifier Characters A 5 ASCII Character Set A 9 Tell Us What You Think...

Страница 9: ...viii LS 6000i Series Product Reference Guide...

Страница 10: ...e brief descriptions of each chapter in this guide Chapter 1 Introduction provides a product overview and a brief description on using the scanner Chapter 2 Setup provides information on connecting th...

Страница 11: ...nventions The following conventions are used in this document The term LS 6000i applies to the LS 6000i LS 6004i LS 6005i and LS 6007i except where specifically noted Bullets indicate action items lis...

Страница 12: ...and Call the Support Center from a phone near the scanning equipment so that the service person can try to talk you through your problem If the equipment is found to be working properly and the proble...

Страница 13: ...in United States Symbol Technologies Inc One Symbol Plaza Holtsville New York 11742 1300 1 800 653 5350 Canada Symbol Technologies Canada Inc 2540 Matheson Boulevard East Mississauga Ontario Canada L4...

Страница 14: ...ustria Denmark Symbol Technologies AS Gydevang 2 DK 3450 Allerod Denmark 7020 1718 Inside Denmark 45 7020 1718 Outside Denmark Europe Mid East Distributor Operations Contact your local distributor or...

Страница 15: ...0 Boca Raton Florida 33434 USA 1 800 347 0178 Inside United States 1 561 483 1275 Outside United States Mexico Symbol Technologies Mexico Ltd Torre Picasso Boulevard Manuel Avila Camacho No 88 Lomas d...

Страница 16: ...1 Scott Street Waverly 2090 Johannesburg Republic of South Africa 11 4405668 Inside South Africa 27 11 4405668 Outside South Africa Spain Symbol Technologies S A Edificioi la Piovera Azul C Peonias No...

Страница 17: ...as been repaired or altered unless done or approved by Symbol ii which has not been maintained in accordance with any operating or handling instructions supplied by Symbol iii which has been subjected...

Страница 18: ...e F O B Symbol s manufacturing plant Symbol will use new or refurbished parts at its discretion and will own all parts removed from repaired products Customer will pay for the replacement product in c...

Страница 19: ...ties on part of Symbol for damages including without limitation special indirect or consequential damages arising out of or in connection with the use or performance of the product Seller s liability...

Страница 20: ...with an optional presentation stand The LS 6000i successfully reads most code symbologies densities and colors produced by a wide range of printing techniques The LS 6000i scanner supports the follow...

Страница 21: ...ntire line of IBM 468X 469X terminals It also accommodates the full line of Synapse Smart Cables LS 6005i I090 IBM 468X 469X with EAS The LS 6005i I090 also provides additional signal lines for EAS de...

Страница 22: ...cted to the scanner the scanner powers up The green LED on top of the scanner illuminates and 3 power up beeps sound indicating the scanner is operational The LS 6000i s LED and beeper indicate scanni...

Страница 23: ...LS 6000i Series Product Reference Guide 1 4...

Страница 24: ...he Symbol Support Center at one of the telephone numbers listed on page xii KEEP THE PACKING It is the approved shipping container and should be used if you ever need to return your equipment for serv...

Страница 25: ...2 1 Plugging Connector into Scanner 3 Gently tug the cable to ensure the connector is properly secured Switching Cables Different cables are required for different hosts To change the scanner cable 1...

Страница 26: ...e U S call 609 848 1800 ext 4900 If you are using an EAS cable refer to the Universal Cable EAS Installation Sheet Symbol p n 70 32824 XX Connecting to a Host Following are detailed instructions for c...

Страница 27: ...rminal by scanning the appropriate bar code s Depending on your terminal these are located either in Chapter 5 Programming or the Synapse Interface Guide 7 Power up the host terminal Ensure that the s...

Страница 28: ...rogrammable by the bar codes in Trigger Mode on page 5 54 Combination Mode Default The omnidirectional scan pattern is always on and ready to decode When the trigger is pulled the scanner emits a sing...

Страница 29: ...To scan in hand held mode pick up the scanner and hold it within the scanning range for the bar code If the scanner is in the constant on mode it decodes the bar code automatically If the scanner is...

Страница 30: ...seated The scanner emits a constant on omnidirectional pattern To scan a bar code bring the bar code anywhere within 10 in 25 4 cm of the scanner window for a successful decode Bar codes can either be...

Страница 31: ...es Product Reference Guide 3 4 When the LS 6000i is removed from the Presentation Stand the scanner operates in the programmed trigger mode see Scanning In Hand Held Mode on page 3 1 for trigger mode...

Страница 32: ...eep when it successfully reads a bar code There are three volume settings for this decode beep To change the setting scan the programming bar codes for Beeper Volume on page 5 57 To adjust the frequen...

Страница 33: ...status as follows Table 3 1 Beeper Indications Beeper Indication 3 Beeps Power up or reset has occurred 1 Beep A bar code has been successfully decoded 4 Beeps A transmission error has occurred Bar co...

Страница 34: ...ons LED Indication Off No power is applied to the scanner On steady The scanner is on and ready to scan or a flash download cable is attached Momentary flash off A bar code has been successfully decod...

Страница 35: ...LS 6000i Series Product Reference Guide 3 8...

Страница 36: ...leaning of the scan window to remove fingerprints or other debris Since the LS 6000i scan window is a high performance optical element care should be given during cleaning Use only a mild soap and wat...

Страница 37: ...ry long and narrow ones easily from almost any angle The scan pattern is projected directly out of the scan window creating the three dimensional scan zone shown below To read a bar code present the b...

Страница 38: ...ine Scan Pattern 60 scans per second Decode Depth of Field Maximum working distance is 10 in 25 4 cm on 100 UPC EAN symbol Decode Capability UPC EAN JAN with and without supplementals Code 128 Code 39...

Страница 39: ...and natural outdoor direct sunlight lighting conditions Flourescent incandescent mercury vapor sodium vapor 450 ft candles Sunlight 9000 ft candles Weight 7 4 oz 210 gm Height 7 64 in 194 mm Width 2 7...

Страница 40: ...r is properly connected The scanner is not decoding and the green LED is lit Check the bar code to make sure it is not defaced Verify that the code type you are scanning is enabled Verify that the sym...

Страница 41: ...is connected to the terminal Make sure the host terminal is properly configured Be sure that you ve scanned the proper host type If you re using RS 232 be sure all RS 232 parameters e g baud rate dat...

Страница 42: ...ge these default values by scanning the appropriate bar codes included in this manual These new values replace the standard default values in memory The default parameter values can be recalled by sca...

Страница 43: ...4683 after you hear the power up beeps select the proper port from the choices in IBM 46XX Host Types LS 6005i on page 5 11 Defaults The following table lists the defaults for all parameters If you wi...

Страница 44: ...Low 5 36 Stop Bit Select 1 5 37 ASCII Format 8 Bit 5 38 Beep on BEL Disable 5 39 Intercharacter Delay 0 5 40 USB LS 6007i 5 41 Set USB Defaults 5 41 USB Device Type IBM Hand Held USB 5 41 Country Sele...

Страница 45: ...inuous Omnidirectional 0 5 seconds 5 56 Beeper Volume High 5 57 Beeper Frequency High Frequency 5 59 Time out Between Decodes Same Symbol Triggered 200 msec Constant On 600 msec 5 61 Time out Between...

Страница 46: ...71 EAN 8 Enable 5 73 EAN 13 Enable 5 73 Bookland EAN Disable 5 75 Decode UPC EAN Supplementals Ignore 5 76 Decode UPC EAN Supplemental Redundancy 20 5 78 Transmit UPC A Check Digit Enable 5 79 Transm...

Страница 47: ...84 Convert UPC E to A Disable 5 86 EAN 8 Zero Extend Disable 5 87 UPC EAN Predecode Block Reject 5 88 UPC EAN Security Levels 0 5 90 Linear UPC EAN Decode Disable 5 93 Linear Supplemental Decode Disa...

Страница 48: ...01 Code 39 Code 39 Enable 5 102 Set Length s for Code 39 1 to 55 5 103 Code 39 Check Digit Verification Disable 5 106 Transmit Code 39 Check Digit Disable 5 107 Code 39 Decode Performance Enable Level...

Страница 49: ...Verification Disable 5 116 Transmit I 2 of 5 Check Digit Disable 5 118 Convert I 2 of 5 to EAN 13 Disable 5 119 Codabar Codabar Disable 5 120 Set Lengths for Codabar 5 55 5 121 CLSI Editing Disable 5...

Страница 50: ...tions Transmit Code ID Character None 5 129 Pause Duration 0 5 132 Prefix Suffix Values 7013 CR LF for serial 5 133 Scan Data Transmission Format Data as is 5 134 Numeric Bar Codes 5 138 Table 5 1 Def...

Страница 51: ...LS 6000i Series Product Reference Guide 5 10 Set Default Parameter Scanning this bar code returns all parameters to the default values listed in Table 5 1 beginning on page 5 2 SET ALL DEFAULTS...

Страница 52: ...the following bar code menus IBM 46XX Host Types LS 6005i To select one of the following as a POS Interface scan the appropriate bar code below Note To properly communicate with 468X 9X terminals the...

Страница 53: ...LS 6000i Series Product Reference Guide 5 12 Host Type Cont d Port 9B Port 17 9E...

Страница 54: ...ts take precedence over standard defaults So if you select Fujitsu RS 232C then select the standard defaults the Fujitsu defaults still take precedence Table 5 2 Terminal Specific RS 232C Parameter St...

Страница 55: ...Sec 2 Sec 9 9 Sec Stop Bit Select One One One One ASCII Format 8 Bit 8 Bit 8 Bit 8 Bit Beep On BEL Disabled Disabled Disabled Disabled RTS Line State Low High Low Low No data to send In the Nixdorf M...

Страница 56: ...rs are not programmable and are separate from the Transmit Code ID feature The Transmit Code ID feature should not be enabled for these terminals Table 5 3 Terminal Specific Code ID Characters ICL FUJ...

Страница 57: ...LS 6000i Series Product Reference Guide 5 16 RS 232C Host Types Cont d To select an RS 232C Host Interface scan one of the following bar codes STANDARD RS 232C ICL RS 232C...

Страница 58: ...Programming 5 17 RS 232C Host Types Cont d NIXDORF RS 232C Mode A NIXDORF RS 232C Mode B...

Страница 59: ...LS 6000i Series Product Reference Guide 5 18 RS 232C Host Types Cont d FUJITSU RS 232C...

Страница 60: ...ate is the number of bits of data transmitted per second The scanner s baud rate setting should match the data rate setting of the host device If not data may not reach the host device or may reach it...

Страница 61: ...LS 6000i Series Product Reference Guide 5 20 Baud Rate Cont d BAUD RATE 600 BAUD RATE 1200...

Страница 62: ...Programming 5 21 Baud Rate Cont d BAUD RATE 2400 BAUD RATE 4800...

Страница 63: ...LS 6000i Series Product Reference Guide 5 22 Baud Rate Cont d BAUD RATE 9600 BAUD RATE 19 200...

Страница 64: ...ificant bit of each ASCII coded character Select the parity type according to host device requirements Odd If you select ODD parity the parity bit has a value 0 or 1 based on data to ensure than an od...

Страница 65: ...5 24 Parity Cont d Even If you select EVEN parity the parity bit has a value 0 or 1 based on data to ensure than an even number of 1 bits are contained in the coded character EVEN Mark Select MARK par...

Страница 66: ...Programming 5 25 Parity Cont d Space Select SPACE parity and the parity bit is always 0 SPACE None Select None if no parity is desired NONE...

Страница 67: ...5 26 Check Receive Errors Select whether or not the parity framing and overrun of received characters are checked The type of parity used is selectable through the PARITY parameter CHECK FOR RECEIVED...

Страница 68: ...o negate the CTS line If after 2 seconds default the CTS line is still asserted the scanner sounds a transmit error and any scanned data is lost When the CTS line is negated the controller asserts the...

Страница 69: ...canner sounds a transmission error and the data is discarded If the above communications sequence fails the scanner issues an error indication In this case the data is lost and must be rescanned If Ha...

Страница 70: ...ard RTS CTS Hardware Handshaking STANDARD RTS CTS RTS CTS Option 1 When RTS CTS Option 1 is selected the scanner asserts RTS before transmitting and ignores the state of CTS The scanner deasserts RTS...

Страница 71: ...thin 2 seconds default the scanner issues an error indication and discards the data RTS CTS OPTION 2 RTS CTS Option 3 When Option 3 is selected the scanner asserts RTS prior to any data transmission r...

Страница 72: ...r instead of that offered by hardware handshaking There are five options If Software Handshaking and Hardware Handshaking are both enabled Hardware Handshaking takes precedence Scan the appropriate ba...

Страница 73: ...mits the same data again and waits for either an ACK or NAK After three unsuccessful attempts to send data when NAKs are received the scanner issues an error indication and discards the data The scann...

Страница 74: ...from the host before transmitting data If an ENQ is not received within 2 seconds the scanner issues an error indication and discards the data The host must transmit an ENQ character at least every 2...

Страница 75: ...the scanner has data to send it then waits for an XON character before transmission The scanner waits up to 2 seconds to receive the XON If the XON is not received within this time the scanner issues...

Страница 76: ...nly applies when in one of the ACK NAK Software Handshaking modes or RTS CTS Hardware Handshaking option The delay period can range from 0 0 to 9 9 seconds in 0 1 second increments After scanning the...

Страница 77: ...roduct Reference Guide 5 36 RTS Line State This parameter is used to set the idle state of the Serial Host RTS line Scan a bar code below to select LOW RTS line state or HIGH RTS line state HOST LOW R...

Страница 78: ...mission of one character and prepares the receiving device for the next character in the serial data stream The number of stop bits selected one or two depends on the number the receiving terminal is...

Страница 79: ...LS 6000i Series Product Reference Guide 5 38 ASCII Format This parameter allows the scanner to interface with devices requiring a 7 bit or 8 bit ASCII protocol 7 BIT 8 BIT...

Страница 80: ...nabled the scanner issues a beep when a BEL character is detected on the RS 232C serial line BEL is issued to gain a user s attention to indicate an illegal entry or other important event BEEP ON BEL...

Страница 81: ...st system time to service its receiver and perform other tasks between characters The delay period can range from no delay to 99 msec in 1 msec increments After scanning the bar code below scan two ba...

Страница 82: ...device options below depending on the host type and desired mode of operation The mode of operation can be dynamically changed However the scanner resets and re enumerates each time a new mode is sele...

Страница 83: ...This mode is supported by a Symbol bar code reader driver and provides maximal flexibility and control over the scanner The software will prompt you to select or install the driver Follow the instruc...

Страница 84: ...Programming 5 43 Note When changing USB Device Types the LS 6007i turns off briefly and re enumerates to properly communicate with the host...

Страница 85: ...LS 6000i Series Product Reference Guide 5 44 Default USB Type IBM Table Top USB IBM Hand Held USB Default...

Страница 86: ...mulation device The MacOS and Windows implement international keyboards differently Select the desired country according to the USB host device If your host platform does not appear here select the Wi...

Страница 87: ...ies Product Reference Guide 5 46 Note When changing the Country Selection the LS 6007i turns off briefly and re enumerates to properly communicate with the host North American Standard USB Keyboard Fr...

Страница 88: ...Programming 5 47 German Windows German MacOS French Canadian Windows French Canadian MacOS...

Страница 89: ...LS 6000i Series Product Reference Guide 5 48 Italian Windows Italian MacOS Spanish ISO MacOS Spanish Traditional Windows...

Страница 90: ...Programming 5 49 Swedish MacOS UK English Windows Swedish Windows...

Страница 91: ...LS 6000i Series Product Reference Guide 5 50 Japanese Windows Japanese MacOS French MacOS UK English MacOS...

Страница 92: ...tion applies only to the HID Keyboard Emulation device Select the desired delay between transmitted keystrokes Only change this setting for slower host PCs that cannot accommodate the speed of data tr...

Страница 93: ...sabled and the case of the bar code data is not preserved For example if the CAPS LOCK is off and an uppercase character is transmitted the host reads this as a lowercase character By selecting Enable...

Страница 94: ...recognize When Send Bar Codes With Unknown Characters is selected all bar code data is sent except for unknown characters and no error beeps sound When Do Not Send Bar Codes With Unknown Characters i...

Страница 95: ...In Triggered Single Scan Line Mode a single scan line appears upon trigger pull If Combination Mode is selected the omnidirectional scan pattern is always on and ready to decode When the trigger is p...

Страница 96: ...Programming 5 55 Trigger Mode Cont d TRIGGERED SINGLE SCAN LINE MODE TRIGGERED OMNIDIRECTIONAL MODE...

Страница 97: ...9 9 seconds If this value is set to 0 the trigger mode will not return to constant on omnidirectional automatically In this case pull the trigger twice quickly to return to the constant on omnidirect...

Страница 98: ...Programming 5 57 Beeper Volume To select a decode beep volume scan the LOW VOLUME MEDIUM VOLUME or HIGH VOLUME bar code LOW VOLUME...

Страница 99: ...LS 6000i Series Product Reference Guide 5 58 Beeper Volume Cont d MEDIUM VOLUME HIGH VOLUME...

Страница 100: ...Programming 5 59 Beeper Frequency To select a decode beep frequency tone scan the LOW FREQUENCY MEDIUM FREQUENCY or HIGH FREQUENCY bar code LOW FREQUENCY...

Страница 101: ...LS 6000i Series Product Reference Guide 5 60 Beeper Frequency Cont d MEDIUM FREQUENCY HIGH FREQUENCY...

Страница 102: ...crements from 0 0 to 9 9 seconds Setting this above 0 4 seconds is recommended Scan the bar code below to select a new time out Next scan two numeric bar codes beginning on page 5 138 the first repres...

Страница 103: ...ferent symbols It is programmable in 0 1 second increments from 0 0 to 9 9 seconds Scan the bar code below then scan two numeric bar codes beginning on page 5 138 the first representing seconds the se...

Страница 104: ...set a Laser On Time scan the bar code below Next scan two numeric bar codes beginning on page 5 138 that correspond to the desired time on Single digit numbers must have a leading zero For example to...

Страница 105: ...scanning activity Scan one of the four options Depending on the selection the scanner enters a low power rest mode 15 30 60 or 90 minutes after the last attempted decode The laser blinks during this...

Страница 106: ...Programming 5 65 Rest Mode Timeout Cont d 60 MINUTES 90 MINUTES...

Страница 107: ...fter Good Decode Scan a bar code below to select whether or not the unit beeps after a good decode If disabled the beeper still operates during parameter menu scanning and indicates error conditions B...

Страница 108: ...eaved 2 of 5 Higher security levels are selected for decreasing levels of bar code quality As security levels increase the scanner s aggressiveness decreases Select the security level appropriate for...

Страница 109: ...eries Product Reference Guide 5 68 Linear Security Level 2 The following code types must be successfully read twice before being decoded Code Type Length All All LINEAR SECURITY LEVEL 1 LINEAR SECURIT...

Страница 110: ...ully read twice before being decoded The following codes must be read three times Linear Security Level 4 The following code types must be successfully read three times before being decoded Code Type...

Страница 111: ...LS 6000i Series Product Reference Guide 5 70 LINEAR SECURITY LEVEL 4...

Страница 112: ...Programming 5 71 UPC EAN Options Enable Disable UPC E To enable or disable UPC E scan the appropriate bar code ENABLE UPC E DISABLE UPC E...

Страница 113: ...LS 6000i Series Product Reference Guide 5 72 Enable Disable UPC A To enable or disable UPC A scan the appropriate bar code ENABLE UPC A DISABLE UPC A...

Страница 114: ...Programming 5 73 Enable Disable EAN 8 To enable or disable EAN 8 scan the appropriate bar code below ENABLE EAN 8 DISABLE EAN 8...

Страница 115: ...LS 6000i Series Product Reference Guide 5 74 Enable Disable EAN 13 To enable or disable EAN 13 scan the appropriate bar code below ENABLE EAN 13 DISABLE EAN 13...

Страница 116: ...Programming 5 75 Enable Disable Bookland EAN To enable or disable EAN Bookland scan the appropriate bar code below ENABLE BOOKLAND EAN DISABLE BOOKLAND EAN...

Страница 117: ...not decoded If UPC EAN without supplemental characters is selected and the LS 6000i is presented with a UPC EAN plus supplemental symbol the UPC EAN is decoded and the supplemental characters ignored...

Страница 118: ...Programming 5 77 Decode UPC EAN Supplementals Cont d DECODE UPC EAN WITH SUPPLEMENTALS IGNORE UPC EAN WITH SUP PLEMENTALS AUTODISCRIMINATE UPC EAN SUPPLEMENTALS...

Страница 119: ...m two to twenty times Five or above is recommended when decoding a mix of UPC EAN symbols with and without supplementals and the autodiscriminate option is selected Scan the bar code below to select a...

Страница 120: ...rogramming 5 79 Transmit UPC A Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC A check digit TRANSMIT UPC A CHECK DIGIT DO NOT TRANSMIT UPC A CHECK DIGIT...

Страница 121: ...Product Reference Guide 5 80 Transmit UPC E Check Digit Scan the appropriate bar code below to transmit the symbol with or without the UPC E check digit TRANSMIT UPC E CHECK DIGIT DO NOT TRANSMIT UPC...

Страница 122: ...be embedded in a UPC A or EAN 13 bar code for additional price verification To enable either of these options or disable the option completely scan the appropriate bar code below DISABLE RANDOM WEIGHT...

Страница 123: ...ns are given for lead in characters for UPC A symbols transmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The...

Страница 124: ...Programming 5 83 UPC A Preamble Cont d SYSTEM CHARACTER SYSTEM CHARACTER DATA SYSTEM CHARACTER COUNTRY CODE COUNTRY CODE SYSTEM CHARACTER DATA...

Страница 125: ...ns are given for lead in characters for UPC E symbols transmitted to the host device transmit system character only transmit system character and country code 0 for USA and no preamble transmitted The...

Страница 126: ...Programming 5 85 UPC E Preamble Cont d SYSTEM CHARACTER SYSTEM CHARACTER DATA SYSTEM CHARACTER COUNTRY CODE COUNTRY CODE SYSTEM CHARACTER DATA...

Страница 127: ...data to UPC A format before transmission After conversion data follows UPC A format and be affected by UPC A programming selections e g Preamble Check Digit Scanning DO NOT CONVERT UPC E TO UPC A allo...

Страница 128: ...arameter is enabled five leading zeros are added to decoded EAN 8 symbols to make them compatible in format to EAN 13 symbols Disabling this parameter returns EAN 8 symbols to their normal format ENAB...

Страница 129: ...Reject Predecode Block This option provides additional protection beyond the embedded check digit against mis splicing a UPC EAN block from a symbol that has just been decoded but has not completely...

Страница 130: ...Programming 5 89 Accept Predecode Block This option allows immediate decode of a new UPC EAN bar code regardless of the previously decoded UPC EAN bar code s block content ACCEPT PREDECODE BLOCK...

Страница 131: ...veness so be sure to choose only that level of security necessary for any given application UPC EAN Security Level 0 This is the default setting which allows the scanner to operate in its most aggress...

Страница 132: ...UPC EAN Security Level 2 If you are experiencing misdecodes of poorly printed bar codes and the misdecodes are not limited to characters 1 2 7 and 8 select this security level UPC EAN SECURITY LEVEL...

Страница 133: ...extreme measure against misdecoding severely out of spec bar codes Selection of this level of security significantly impairs the decoding ability of the scanner If this level of security is necessary...

Страница 134: ...nt blocks e g UPC A EAN 8 EAN 13 When enabled a bar code is transmitted only when both the left and right blocks are successfully decoded within one laser scan This option should be enabled when bar c...

Страница 135: ...r five character supplementals When enabled a bar code is transmitted only when both the supplemental block and its adjacent block are successfully decoded within one laser scan This option should be...

Страница 136: ...mentals Increasing the performance level reduces the amount of required bar code orientation which is useful if you are scanning very long and or truncated bar codes Increased levels reduce decode sec...

Страница 137: ...duct Reference Guide 5 96 UPC EAN Decode Performance Cont d If Decode Performance is enabled select a level below UPC EAN DECODE PERFORMANCE LEVEL 1 UPC EAN DECODE PERFORMANCE LEVEL 2 UPC EAN DECODE P...

Страница 138: ...s parameter decodes UPC A UPC A with 2 supplemental characters UPC A with 5 supplemental characters and UPC A EAN 128 bar codes Autodiscriminate UPC EAN With Supplemental Characters must be enabled EN...

Страница 139: ...LS 6000i Series Product Reference Guide 5 98 Code 128 Options Enable Disable Code 128 To enable or disable Code 128 scan the appropriate bar code below ENABLE CODE 128 DISABLE CODE 128...

Страница 140: ...the performance level reduces the amount of required bar code orientation which is useful if you are scanning very long and or truncated bar codes Increased levels reduce decode security If you enabl...

Страница 141: ...ct Reference Guide 5 100 Code 128 Decode Performance Cont d If Decode Performance is enabled select a level below CODE 128 DECODE PERFORMANCE LEVEL 1 CODE 128 DECODE PERFORMANCE LEVEL 2 CODE 128 DECOD...

Страница 142: ...Programming 5 101 Enable Disable UCC EAN 128 To enable or disable UCC EAN 128 scan the appropriate bar code below See Appendix A for details on UCC EAN 128 ENABLE UCC EAN 128 DISABLE UCC EAN 128...

Страница 143: ...LS 6000i Series Product Reference Guide 5 102 Code 39 Options Enable Disable Code 39 To enable or disable Code 39 scan the appropriate bar code below ENABLE CODE 39 DISABLE CODE 39...

Страница 144: ...ny Length are the preferred options One Discrete Length This option allows you to decode only those codes containing a selected length For example if you select Code 39 One Discrete Length then scan 1...

Страница 145: ...e 5 143 CODE 39 TWO DISCRETE LENGTHS Length Within Range This option allows you to decode a code type within a specified range For example to decode Code 39 symbols containing between 4 and 12 charact...

Страница 146: ...Programming 5 105 Any Length Scanning this option allows you to decode Code 39 symbols containing any number of characters CODE 39 ANY LENGTH...

Страница 147: ...When enabled this parameter checks the integrity of a Code 39 symbol to ensure it complies with specified algorithms Only those code 39 symbols which include a modulo 43 check digit are decoded when t...

Страница 148: ...rogramming 5 107 Transmit Code 39 Check Digit Scan a bar code below to transmit the data with or without the check digit TRANSMIT CODE 39 CHECK DIGIT ENABLE DO NOT TRANSMIT CODE 39 CHECK DIGIT DISABLE...

Страница 149: ...level reduces the amount of required bar code orientation which is useful if you are scanning very long and or truncated bar codes Increased levels reduce decode security If you enable this option yo...

Страница 150: ...amming 5 109 Code 39 Decode Performance Cont d If Decode Performance is enabled select a level below CODE 39 DECODE PERFORMANCE LEVEL 1 CODE 39 DECODE PERFORMANCE LEVEL 2 CODE 39 DECODE PERFORMANCE LE...

Страница 151: ...such as BACKSPACE and RETURN The other 96 are called printable codes because all but SPACE and DELETE produce visible characters Code 39 Full ASCII interprets the bar code special character preceding...

Страница 152: ...Programming 5 111 Enable Disable Code 39 Full ASCII Cont d ENABLE CODE 39 FULL ASCII DISABLE CODE 39 FULL ASCII...

Страница 153: ...oduct Reference Guide 5 112 Interleaved 2 of 5 Options Enable Disable Interleaved 2 of 5 To enable or disable Interleaved 2 of 5 scan the appropriate bar code below ENABLE INTERLEAVED 2 OF 5 DISABLE I...

Страница 154: ...Discrete Length This option allows you to decode only those codes containing a selected length For example if you select I 2 of 5 One Discrete Length then scan 1 4 the only I 2 of 5 symbols decoded a...

Страница 155: ...ange This option allows you to decode a code type within a specified range For example to decode I 2 of 5 symbols containing between 4 and 12 characters first scan I 2 of 5 Length Within Range Then sc...

Страница 156: ...5 115 Any Length Scanning this option allows you to decode I 2 of 5 symbols containing any number of characters Note Selecting the Any Length option may lead to misdecodes for I 2 of 5 codes I 2 of 5...

Страница 157: ...116 I 2 of 5 Check Digit Verification When enabled this parameter checks the integrity of an I 2 of 5 symbol to ensure it complies a specified algorithm either Uniform Symbology Specification USS or...

Страница 158: ...Programming 5 117 I 2 of 5 Check Digit Verification Cont d USS CHECK DIGIT OPCC CHECK DIGIT...

Страница 159: ...Product Reference Guide 5 118 Transmit I 2 of 5 Check Digit Scan a bar code below to transmit the data with or without the check digit TRANSMIT I 2 of 5 CHECK DIGIT ENABLE DO NOT TRANSMIT I 2 of 5 CHE...

Страница 160: ...5 code into EAN 13 and transmits to the host as EAN 13 In order to accomplish this the I 2 of 5 code must be enabled one length must be set to 14 and the code must have a leading zero and a valid EAN...

Страница 161: ...LS 6000i Series Product Reference Guide 5 120 Codabar Options Enable Disable Codabar To enable or disable Codabar scan the appropriate bar code below ENABLE CODABAR DISABLE CODABAR...

Страница 162: ...ons One Discrete Length This option allows you to decode only those codes containing a selected length For example if you select Codabar One Discrete Length then scan 1 4 the only Codabar symbols deco...

Страница 163: ...n Range This option allows you to decode a code type within a specified range For example to decode Codabar symbols containing between 4 and 12 characters first scan Codabar Length Within Range Then s...

Страница 164: ...Programming 5 123 Any Length Scanning this option allows you to decode Codabar symbols containing any number of characters CODABAR ANY LENGTH...

Страница 165: ...en enabled this parameter strips the start and stop characters and inserts a space after the first fifth and tenth characters of a 14 character Codabar symbol Note Symbol length does not include start...

Страница 166: ...Programming 5 125 NOTIS Editing When enabled this parameter strips the start and stop characters from decoded Codabar symbol ENABLE NOTIS EDITING DISABLE NOTIS EDITING...

Страница 167: ...LS 6000i Series Product Reference Guide 5 126 RSS Codes RSS 14 Enable RSS 14 Disable RSS 14...

Страница 168: ...Programming 5 127 RSS Limited Enable RSS Limited Disable RSS Limited...

Страница 169: ...LS 6000i Series Product Reference Guide 5 128 RSS Expanded Enable RSS Expanded Disable RSS Expanded...

Страница 170: ...decoding more than one code type In addition to any single character prefix already selected the code ID character is inserted between the prefix and the decoded symbol The user may select no code ID...

Страница 171: ...pe Symbol Identifier UPC A UPC E UPC E1 EAN 13 EAN 8 A Code 39 Code 32 B Codabar C Code 128 ISBT 128 D Code 93 E Interleaved 2 of 5 F Discrete 2 of 5 D 2 of 5 IATA G MSI Plessey J UCC EAN 128 K Bookla...

Страница 172: ...Programming 5 131 Transmit Code ID Character Cont d AIM CODE ID CHARACTER NONE...

Страница 173: ...set by scanning a two digit number i e two bar codes and are measured in 1 10 second intervals For example scanning bar codes 0 and 1 inserts a 1 10 second pause 0 and 5 gives you a 1 2 second delay...

Страница 174: ...s are set by scanning a four digit number i e four bar codes that corresponds to key codes for various terminals See Table A 4 in Appendix A for conversion information Numeric bar codes begin on page...

Страница 175: ...at To change the Scan Data Transmission Format scan the SCAN OPTIONS bar code below Then select one of four options When you have made your selection scan the ENTER bar code on page 5 137 If you make...

Страница 176: ...Programming 5 135 Scan Data Transmission Format Cont d DATA AS IS DATA SUFFIX...

Страница 177: ...LS 6000i Series Product Reference Guide 5 136 Scan Data Transmission Format Cont d PREFIX DATA PREFIX DATA SUFFIX...

Страница 178: ...Programming 5 137 Scan Data Transmission Format Cont d ENTER DATA FORMAT CANCEL...

Страница 179: ...LS 6000i Series Product Reference Guide 5 138 Numeric Bar Codes For parameters requiring specific numeric values scan the appropriately numbered bar code s 0 1...

Страница 180: ...Programming 5 139 Numeric Bar Codes Cont d 2 3...

Страница 181: ...LS 6000i Series Product Reference Guide 5 140 Numeric Bar Codes Cont d 4 5...

Страница 182: ...Programming 5 141 Numeric Bar Codes Cont d 6 7...

Страница 183: ...LS 6000i Series Product Reference Guide 5 142 Numeric Bar Codes Cont d 8 9...

Страница 184: ...Programming 5 143 Cancel If you make an error or wish to change your selection scan the bar code below CANCEL...

Страница 185: ...LS 6000i Series Product Reference Guide 5 144...

Страница 186: ...NC 1 characters are used to delineate fields When EAN 128 symbols are read they are transmitted after special formatting strips off the leading FNC 1 character and replaces other FNC 1 characters with...

Страница 187: ...le or disable one or both code types via bar code menus Table A 1 indicates the behavior of the LS 6000i in each of the four possible parameter settings Table A 1 Reading Standard Code128 UCC EAN 128...

Страница 188: ...be read ABCDFNC1E is read as ABCD29E ABCDE is read as ABCDE Enable Enable Read both types of symbols Examples FNC1ABCDFNC1E are read as ABCD29E AFNC1BCDFNC1E are read as ABCD29E FNC1FNC1ABCDFNC1E are...

Страница 189: ...93 c Code Character see Table A 2 m Modifier Character see Table A 3 Table A 2 AIM Code Identifiers Code Character Code Type A Code 39 C Code 128 ISBT 128 EAN128 E UPC EAN e RSS Family EAN UCC Composi...

Страница 190: ...cessing 1 Reader has checked one check character 3 Reader has checked and stripped check character 4 Reader has performed Full ASCII character conversion 5 Reader has performed Full ASCII character co...

Страница 191: ...FNC1 Aim Id is transmitted as C1AimId I 2 of 5 0 No check digit processing 1 Reader has validated check digit 3 Reader has validated and stripped check digit Example An I 2 of 5 bar code without check...

Страница 192: ...78905 Bookland EAN 0 No options specified at this time Always transmit 0 Example A Bookland EAN bar code 123456789X is transmitted as X0123456789X RSS Family Note In UCC EAN 128 emulation mode RSS is...

Страница 193: ...is transmitted in the following format E0 UPC chars terminator E2 supplemental terminator In the LS 6000i however the format is changed to E0 UPC chars E2 supplemental Therefore a UPC with two supplem...

Страница 194: ...L B 1026 Z CTRL Z 1003 C CTRL C 1027 A CTRL 1004 D CTRL D 1028 B CTRL 1005 E CTRL E 1029 C CTRL 1006 F CTRL F 1030 D CTRL 6 1007 G CTRL G 1031 E CTRL 1008 H CTRL H 1032 Space Space 1009 I CTRL I 1033...

Страница 195: ...1 3 3 1076 L L 1052 4 4 1077 M M 1053 5 5 1078 N N 1054 6 6 1079 O O 1055 7 7 1080 P P 1056 8 8 1081 Q Q 1057 9 9 1082 R R 1058 Z 1083 S S 1059 F 1084 T T 1060 G 1085 U U 1061 H 1086 V V 1062 I 1087 W...

Страница 196: ...ar Keystroke 1098 B b 1113 Q q 1099 C c 1114 R r 1100 D d 1115 S s 1101 E e 1116 T t 1102 F f 1117 U u 1103 G g 1118 V v 1104 H h 1119 W w 1105 I i 1120 X x 1106 J j 1121 Y y 1107 K k 1122 Z z 1108 L...

Страница 197: ...2069 ALT E 2080 ALT P 2091 ALT 2070 ALT F 2081 ALT Q 2092 ALT 2071 ALT G 2082 ALT R 2093 ALT 2072 ALT H 2083 ALT S 2094 ALT 6 2073 ALT I 2084 ALT T 2095 ALT 2074 ALT J 2085 ALT U Misc Key Keystroke M...

Страница 198: ...4008 PF 8 4016 PF 16 4024 PF 24 F Keys Keystroke F Keys Keystroke F Keys Keystroke 5001 F 1 5014 F 14 5027 F 27 5002 F 2 5015 F 15 5028 F 28 5003 F 3 5016 F 16 5029 F 29 5004 F 4 5017 F 17 5030 F 30 5...

Страница 199: ...Lock 6046 6063 5 6060 00 6047 6064 6 6048 0 6065 7 Extended Keypad Keystroke Extended Keypad Keystroke Extended Keypad Keystroke 7001 Break 7008 Backspace 7015 Up Arrow 7002 Delete 7009 Tab 7016 Dn Ar...

Страница 200: ...2 3 modular connector 2 2 scanner cable 2 1 switching 2 2 cancel bar code 5 143 cleaning 4 1 CLSI editing 5 124 code ID characters AIM A 4 Symbol 5 129 connecting to host 2 3 D default table 5 2 defa...

Страница 201: ...amming parameters 5 1 ASCII format 5 38 baud rate 5 19 beep after good decode 5 66 beep on bel 5 39 beeper frequency 5 59 beeper volume 5 57 bookland EAN 5 75 cancel 5 143 check receive errors 5 26 CL...

Страница 202: ...l 5 61 transmit code 39 check digit 5 107 transmit code ID character 5 129 transmit I 2 of 5 check digit 5 118 trigger modes 5 54 UCC EAN 128 5 101 UPC A 5 72 UPC A check digit 5 79 UPC A preamble 5 8...

Страница 203: ...gered single scan line 3 2 service information xi setup 2 1 connecting interface cable 2 3 connecting power supply 2 3 connecting to host 2 3 installing scanner cable 2 1 programming the scanner 2 4 s...

Страница 204: ...How familiar were you with this product before using this manual Did this manual meet your needs If not please explain ________________________________________________________ What topics need to be a...

Страница 205: ...72 51596 01 Revision A July 2001 Symbol Technologies Inc One Symbol Plaza Holtsville New York 11742 1300...

Отзывы: