6
D
C
6
9
4
X
-
0
0
0
D
C
C
o
n
v
e
r
t
e
r
Troubleshooting
Technical Specifications
Symptom
Possible Cause
Action
Terminal is
unable to
power on.
Insufficient volt-
age.
Ensure the Filtered Cable
Assembly is connected to the
forklift power source and that it
has at least 36 volts DC. The
converter will not work if the
input voltage is less than 36
volts.
Cable not
plugged into the
Converter.
Ensure the Filtered Cable
Assembly is plugged securely
into the Converter box.
Cable not
plugged into the
terminal.
Ensure the Converter cable is
plugged securely into the ter-
minal.
Minimum DC input voltage
36 volts
Maximum DC input voltage
75 volts
Output voltage
12 volts DC
Maximum output current
6.25 amps