1. Place the plastic mounting bracket flat against the ceiling tile and use the mounting bracket
as a template to mark the locations of the two mounting holes and the light pipe (the large
hole in the center of the bracket).
2. Use the screws to tap the holes at the locations marked and cut out the marked location of
the light pipe.
3. Install a screw and washer in each hole below the ceiling tile.
4. Place the plastic bracket flat above the ceiling tile, lining up the mounting bracket holes with
the screws.
5. Place one of the washers over each of the screws that are lined up and through the mount-
ing bracket holes.
6. Secure the mounting bracket to the ceiling tile fastening a nut to each screw.
7. Place the decal on the light pipe and install it into the opening in the ceiling tile and into the
mounting bracket so it fits into the mounting bracket light pipe opening.
Note:
When the AP 200 is installed on a thin [approximately 1.27cm (1/2in. thick)] ceiling tile, a
gap of about .64cm (.25in.) - .76cm (.30in.) from the light pipe face to the ceiling tile is normal.
Caution!
Symbol does not recommend mounting the AP 200 directly to any suspended ceiling
tile with a thickness less than 1.27cm (1/2in.) or a suspended ceiling tile with an unsupported
span greater than 66cm (26in.). Symbol recommends that the AP 200 be fitted with a cus-
tomer supplied safety cable suitable for the specific installation. The safety cable should be
steel at least .15cm (.06in.) - .25cm (.10in.) in diameter. Use a cable similar to cable used in a
suspended ceiling installation.
Attaching the AP 200 to the Mounting Bracket
1. Insert the end of the AP 200 (either non-antenna side) into the opening of the installation
bracket.
2. Press down on the other end of the AP 200 until it locks in place (the plastic bracket has
some flex in it and snaps in place).
3. Connect the Ethernet cable (use CAT- 5 or above without any strain relief) to the LAN port.
4. Verify the unit has power by observing the Amber LED.
Note:
To configure the AP 200 refer to the WS 5000 Wireless Switch Online System
Reference guide on the product CD included with the Wireless Switch hardware
Below Suspended Ceiling (T-Bar) Mount
1. Determine the suspended (below) ceiling mounting location of the AP 200.
2. Loosely assemble the two clip halves by holding the clip halves facing each other clip
side up (place the long channel section of one clip half on top of the other) so they form a
"U" shape.
3. Place the flat side of the assembled T-bar clip on the opposite side of the "notch-hook" so
that the opening formed in the center of the clip aligns with the center holes on each end of
the metal mounting bracket.
4. Insert the carriage bolt through the T-bar clip and mounting bracket.
5. Use the wing nut to finger tighten the clip to the bracket. The wing nut secures the clip from
the "notch-hook" side. Repeat steps 2 through 5 for the other T-bar clip.
6. Attach the mounting bracket to the suspended ceiling T-bar with the clips. Spread the clip
halves to allow insertion of the ceiling T- bar's bottom flange.
7. Compress the halves until they fully engage the T-bar flange.
8. Secure the bracket to the T-bar by tightening the wing nut holding the clips.
Attaching the AP 200 to the Suspended Ceiling Mounting Bracket
1. Hold the AP 200 up to the bracket with the LEDs facing towards the ground.
2. Face the power/data port connectors away from the extended open metal (raised) part on
the bracket.
3. Align the slot openings along the sides (on the left and right) of the ribbed bottom of the AP
200 to the notch hooks of the mounting bracket.
4. Insert the AP 200 into the bracket until it locks in place and both hooks are fully seated.
5. Connect the Ethernet cable (use CAT- 5 or above without any strain relief) to the LAN port.
6. Verify the unit has power by observing the Amber LED.
Note:
To configure the AP 200 refer to the WS 5000 Wireless Switch Online System
Reference guide on the product CD included with the Wireless Switch hardware.
Available Options
Contact a Symbol sales associate for available AP 200 radio and antenna options.
Radio or Antenna Option
Part Number
.11a Internal antenna
WSM-5040-110-WW
.11a External RSMA Dipole antenna
ML-5299-APA1-01
.11b radio with external antenna connectors
WSM-5030-200-WW
.11b radio with internal antenna
WSM-5030-210-WW
.11b External RBNC dipole antenna
ML 2499-APA1-00
.11b External RBNC high performance single antenna
ML 2499-HPA1-00
.11b Twin high performance diversity antennas
ML 2499-DVA1-00
.11b Mountable F-plane antenna
48-450115-01
Customer Support
Symbol Technologies provides its customers with prompt and accurate customer support. Use
the Symbol Support Center as the primary contact for any technical problem, question or sup-
port issue involving Symbol products.
If the Symbol Customer Support specialists cannot solve a problem, access to all technical
disciplines within Symbol becomes available for further assistance and support. Symbol
Customer Support responds to calls by email, telephone or fax within the time limits set forth in
individual contractual agreements.
When contacting Symbol Customer Support, please provide the following information:
•
Device serial number
•
Product name or model number
•
Software type and version number
North American Contacts
Inside North America, contact Symbol at:
Symbol Technologies, Inc.
One Symbol Plaza
Holtsville, New York 11742-1300
Telephone: 1-631-738-2400/1-800-SCAN 234
Fax: 1-631-738-5990
Symbol Support Center (for warranty and service information):
Telephone: 1-631-738-6213/1-800-653-5350
Fax: (631) 563-5410
Email: [email protected]
International Contacts
Outside North America, contact Symbol at:
Symbol Technologies, Inc.
Symbol Place
Winnersh Triangle, Berkshire, RG41 5TP
United Kingdom
0800-328-2424 (Inside UK)
+44 118 945 7529 (Outside UK)
Web Support sites
MySymbolCare
http://www.symbol.com/services/msc
Symbol Services Homepage
http://symbol.com/services
Symbol Software Updates
http://symbol.com/service
s
/downloads
Symbol Developer Program
http://software.symbol.com/devzone
Symbol Knowledge Base
http://kb.symbol.com/register.asp
Additional Information
Obtain additional information by contacting Symbol at:
•
1-800-722-6234, inside North America
•
+1-631-738-5200, in/outside North America
•
http://www.symbol.com/
Legal Information
Regulatory Information
All Symbol devices are designed to be compliant with rules and regulations in locations they
are sold and will be labeled as required.
Any changes or modifications to Symbol Technologies equipment, not expressly approved by
Symbol Technologies, could void the user's authority to operate the equipment.
Use only the supplied or an approved replacement antenna. Unauthorized antennas, modifica-
tions, or attachments could cause damage and may violate regulations.
This device is to be used only with Symbol Technologies Wireless Switch.
Applying the Regulatory Country Stamp
Regulatory labels are applied to the device signifying the radio(s) are approved for use in the
following countries: United States, Canada, Australia, Japan & Europe 1,2.
Note 1:
For 2.4GHz Products: Europe includes, Austria, Belgium, Croatia, Denmark, Estonia,
Finland, France, Germany, Greece, Iceland, Ireland, Italy, Liechtenstein, Luxembourg,
Netherlands, Norway, Portugal, Spain, Sweden, Switzerland, United Kingdom.
Note 2:
The use of 5GHz RLAN's has varying restrictions of use; please refer to the Symbol
Declaration of Conformity (DoC) for details at http://www2.symbol.com/doc/
In addition to the list above other countries may require a regulatory stamp to be affixed to the
product.
Please refer to www.symbol.com/ for the list of countries where mandatory stamps are
required.
For countries that require regulatory label, a sheet of stamps may be enclosed within
the package.
If the appropriate stamps are not provided, please contact your supplier.
To apply the country stamp:
1. Peel the stamp appropriate to the country where this device is to be used.
2. Apply the country stamp in the space provided on the regulatory label
Operation of the device without a regulatory label or the correct country Stamp is illegal.
FCC RF Exposure Guidelines
Safety Information
The device complies with internationally recognized standards covering Specific
Absorption Rate (SAR) related to human exposure to electromagnetic fields from radio
devices.
It is advisable to use the device only in the normal operating position.
Remote and Standalone Antenna Configurations.
To comply with FCC RF exposure requirements, antennas that are mounted externally at
remote locations or operating near users at stand-alone desktops of similar configurations
must operate with a minimum separation distance of 20cm from all persons.
Power Supply
Use only Symbol approved power supplies 50-24000-049 output rated 48VDC and minimum
1.1amp or 50-24000-050 output rated 48VDC and minimum .25amp. The power supply is cer-
tified to EN60950 with SELV outputs. Use of alternative power supply will invalidate any
approval given to this device and may be dangerous.
Hinweis: Benutzen Sie nur eine Symbol Technologies genehmigt Stromversorgung 50-24000-
049 in den Ausgabe: 48VDC und minimum 1.1A. oder 50-24000-050 in den Ausgabe: 48VDC
und minimum .25A. Die Stromversorgung ist bescheinigt nach EN60950 mit SELV Ausgaben
•
Model 50-24000-049 48VDC power supply
•
Model 50-24000-050 48VDC power supply
•
Model AP-PSBIAS-T-12-AF Power Injector-12 Port
Radio Frequency Interference Requirements
This equipment has been tested and found to com-
ply with the limits for a Class B digital device, pur-
suant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and can radiate
radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communica-
tions. However there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
Reorient or relocate the receiving antenna
•
Increase the separation between the equipment and receiver
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
•
Consult the dealer or an experienced radio/TV technician for help.
Radio Transmitters (Part 15)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Radio Frequency Interference Requirements - Canada
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Radio Transmitters
This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
Label Marking: The Term "IC:" before the radio certification only signifies that Industry Canada
technical specifications were met.
Marking and European Economic Area (EEA)
The use of 2.4GHz RLAN's, for use through the EEA, have the following restrictions:
•
Maximum radiated transmit power of 100mW EIRP in the frequency range 2.400GHz -
2.4835GHz
•
France, equipment is restricted to 2.4465GHz - 2.4835GHz frequency range
•
Belgium outside usage, the equipment is restricted to 2.460GHz - 2.4835 GHz
frequency range
•
Italy requires a user license for outside usage.
The use of 5GHz RLAN's has varying restrictions for use within the EEA; please refer to the
Symbol Declaration of Conformity (DoC) for details at http://www2.symbol.com/doc/
Statement of Compliance
Symbol Technologies, Inc., hereby, declares that this device is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.
A Declaration of Conformity may be obtained from http://www2.symbol.com/doc/
Other Countries
Mexico -
Restrict Frequency Range to: 2.450GHz - 2.4835GHz.
Israel -
Restrict Frequency Range to: 2.418GHz - 2.457GHz.
Sri Lanka- Restrict Frequency Range to: 2.400GHz - 2.430GHz.
(4)
(5)
(7)
Plastic
Mounting
Bracket
1
2
T-Bar
Wing
Nut
T-Bar Clip
Halves
Apart
Wing
Nut
T-Bar Clip
Halves
Together
Notch
Hook
Notch
Hook
Notch
Hook
Tested to Comply
With FCC Standards
For Home or Office Use
Symbol Technologies Inc.
(6)