![symbios logic J21971S-0398 Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/symbios-logic/j21971s-0398/j21971s-0398_installation-manual_1418967075.webp)
Host Interface
SCSI Interface
Revision A, March 1998
Technical Reference
65
SCSI Drive Pin Assignments and Signals
lists the SCA-2 interface pin assignments for the SCSI disk
drives.
describes each SCSI signal.
Table 12
SCA-2 Interface Pin Assignments
6
6
6
6
1
+12 V charge
21
DB(7)
41
GROUND
61
GROUND
2
+12 V
22
DB(6)
42
GROUND
62
GROUND
3
+12 V
23
DB(5)
43
GROUND
63
GROUND
4
+12 V
24
DB(4)
44
Mated 1
64
GROUND
5
NC (Opt. 3.3 V)
25
DB(3)
45
NC (Opt. 3.3 V charge)
65
GROUND
6
NC (Opt. 3.3 V)
26
DB(2)
46
GROUND
66
GROUND
7
DB(11)
27
DB(1)
47
GROUND
67
GROUND
8
DB(10)
28
DB(0)
48
GROUND
68
GROUND
9
DB(9)
29
DB(P1)
49
GROUND
69
GROUND
10
DB(8
30
DB(15)
50
GROUND
70
GROUND
11
I/O
31
DB(14)
51
GROUND
71
GROUND
12
REQ
32
DB(13)
52
GROUND
72
GROUND
13
C/D
33
DB(12)
53
GROUND
73
GROUND
14
SEL
34
+5 V
54
GROUND
74
Mated Ground
15
MSG
35
+5 V
55
GROUND
75
GROUND
16
RST
36
+5 V charge
56
GROUND
76
GROUND
17
ACK
37
SYNC +
57
GROUND
77
ACTIVE_LED
18
BSY
38
RMT_START
58
GROUND
78
DLYD_START
19
ATN
39
SCSI ID0 +
59
GROUND
79
SCSI ID1 +
20
DB(P)
40
SCSI ID2 +
60
GROUND
80
SCSI ID3 +
Содержание J21971S-0398
Страница 1: ...MetaStor Command Module Installation Guide J21971S 0398 Revision A ...
Страница 8: ...vi MetaStor Command Module Installation Guide Revision A March 1998 ...
Страница 10: ...viii MetaStor Command Module Installation Guide Revision A March 1998 ...
Страница 84: ...Index 6 MetaStor Command Module Installation Guide Revision A March 1998 ...
Страница 85: ......
Страница 86: ... Symbios Logic Inc Printed in the USA J21971S 0398 Revision A ...