43
Upgrading the product
Upgrading from 3.5 to 5.0
8
Uninstall VCS 3.5 from all the nodes. Run the following commands from one
of the nodes.
See the
Veritas Cluster Server Installation Guide
.
# cd /opt/VRTSvcs/install
# ./uninstallvcs
Note:
Ignore any errors from the
uninstallvcs
script and proceed with
the uninstall of VCS.
9
Upgrade the operating system from HP-UX 11i Version 1 to HP-UX 11i
Version 2 on all the nodes.
See the
HP-UX Operating System
documentation.
10
Install all the prerequisite patches on all the nodes. See section “
Required
HP-UX patches
” on page 15.
11
Install SFCFS 5.0 and reboot all the nodes.
See “
Installing the product
” on page 19.
Note:
Do not configure SFCFS after reboot.
12
Start
vxfen
on all the nodes.
vxfen
can be started either in disable or enable
mode. For starting
vxfen
in disabled mode, run the following commands:
# cat vxfen_mode=disabled > /etc/vxfenmode