Symantec PacketShaper PS-S200 Скачать руководство пользователя страница 2

Copyright © 2017 Symantec Corp. All rights reserved. Symantec, the Symantec Logo, the Checkmark Logo, Blue Coat, and the Blue Coat logo are trademarks or registered trademarks of Symantec Corp. or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners. This document is provided for informational purposes only and is not intended as advertising. All warranties relating to the information in this 
document, either express or implied, are disclaimed to the maximum extent allowed by law. The information in this document is subject to change without notice. Part Number: 231-03313 Rev A.0

THE DOCUMENTATION IS PROVIDED “AS IS” AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT, ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID. SYMANTEC CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR 
CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, PERFORMANCE, OR USE OF THIS DOCUMENTATION. THE INFORMATION CONTAINED IN THIS DOCUMENTATION IS SUBJECT TO CHANGE WITHOUT NOTICE. SYMANTEC CORPORATION PRODUCTS, TECHNICAL SERVICES, AND ANY OTHER TECHNICAL DATA REFERENCED IN THIS DOCUMENT ARE SUBJECT TO U.S. EXPORT CONTROL AND SANCTIONS LAWS, REGULATIONS AND 
REQUIREMENTS, AND MAY BE SUBJECT TO EXPORT OR IMPORT REGULATIONS IN OTHER COUNTRIES. YOU AGREE TO COMPLY STRICTLY WITH THESE LAWS, REGULATIONS AND REQUIREMENTS, AND ACKNOWLEDGE THAT YOU HAVE THE RESPONSIBILITY TO OBTAIN ANY LICENSES, PERMITS OR OTHER APPROVALS THAT MAY BE REQUIRED IN ORDER TO EXPORT, RE-EXPORT, TRANSFER IN COUNTRY OR IMPORT AFTER DELIVERY TO YOU.

Page 2

PS-S200, PS-S400, PS-S500 Quick Start Guide

06 

Perform a Graceful Shutdown

Before proceeding to rack-mounting the appliance, log in to the PacketShaper CLI and perform 
a graceful shutdown of the appliance.

To perform a graceful shutdown:

a. 

Log in to the PacketShaper CLI (see 

Step 4

).

b. 

Enter: 

shutdown

Warning: 

Do not power off the appliance with the soft power switch or by removing the power 

cables! Abruptly removing power can result in irreparable data loss. Always use the 

shutdown

 

command from the CLI to power off the appliance.

07 

Rack-Mount the Appliance

The slide-rail mounting kit included with the PS-S400 and PS-S500 appliances (available as an 
option for PS-S200 appliances) allows the appliance to be rack-mounted in a two- or -four-post 
equipment rack. The slide-rail kit includes the following parts:

Note: 

To rack-mount the appliance, you may need an M4 nut driver or adjustable wrench, #2 

Phillips head screwdriver, and rack screws.

Note: 

The following procedure documents how to install the appliance in a four-post equipment 

rack. For comprehensive information on rack-mounting the appliance, including other 
configurations, see the S-Series Maintenance and Upgrade Guide at: 

http://www.symantec.com/docs/DOC9795

To install the appliance in a four-post equipment rack:

a. 

Disassemble the two slide-rail assemblies:

 

o

Fully extend each slide-rail by sliding out the inner rails until they reach the stop.

 

o

Release the white slide latches (toward the rear of the inner rails) and slide the inner rails 
all the way out.

 

o

Slide-rails are symmetrical and can be used with either side of the chassis.

b. 

Attach the two inner rails to the appliance:

 

o

Align each inner rail to the mounting posts on each side of the chassis. Slide the rail 
toward either the front (

PS-S200 

and

 PS-S400

) or rear (

PS-S500

) of the chassis until 

each of the mounting posts snap into place.

 

o

Secure the inner rails to the appliance with M3 screws:

• 

For 

PS-S200

 and 

PS-S400

 appliances, use one M3 screw in the center of each rail.

• 

For 

PS-S500

 appliances, use two M3 screws in each rail.

c. 

For 

PS-S200

 and 

PS-S400

 appliances, install the two rack ears. Align them with the mounting 

posts on the chassis sides near the front of the appliance and secure them with the included 
fasteners.

d. 

Assemble the two slide-rails and install them in the rack:

 

o

Loosely attach Rail_C to Rail_A. Secure the rails with three M3 screws inserted through 
the slot in Rail_C and screwed into three holes in Rail_A. Make sure the screws are 
equidistant from each other so the load will be evenly distributed on the rail. Do not yet 
fully tighten the screws. 

Note: 

The precise attachment location of the screws will depend on how far Rail_C will 

extend or retract to fit the rack. It may be necessary to remove Rail_C from Rail_A to 
determine the proper installation length. 

 

o

Install the assembled slide-rails in the rack:

• 

Secure the front bracket for Rail_A to the outside front of the rack using two rack 
screws. Do not yet fully tighten the screws. You will do so after the appliance is 
installed in the rack.

• 

Extend or retract Rail_C to align the rear bracket with the outside rear of the rack. 
Secure the bracket with two M3 screws. Do not yet fully tighten the screws. You will 
do so after the appliance is installed in the rack.

• 

Tighten the side-mounting screws for Rail_C.

• 

Verify the slide-rail assemblies are installed at the same rack eight.

e. 

Install the appliance in the rack:

 

o

Align the inner rails attached to the appliance with the slide-rails in the rack and slide the 
appliance half-way into the track. 

 

o

Press the gray locking tabs on the inner rails to slide the appliance all the way into the rack.

 

o

Slide the appliance out of the rack, far enough to access the rack screws. Fully tighten 
the rack screws for the front and rear brackets to secure the slide-rails to the rack.

 

o

Gently push the appliance all the way to the back of the rack and tighten the 
thumbscrews on the retaining ears to prevent the appliance from sliding out.

f. 

Reconnect the cables as documented in 

Step 2—Connect Cables

 and verify the appliance is 

functioning as in 

Step 3—Power On the Appliance and Verify LEDs

.

Technical Support

 

o

Contact Information 

https://support.symantec.com/en_US/contact-support.html

 

o

MySymantec 

https://www.mysymantec.com

Documentation

PacketShaper Software Documentation

 

o

http://www.symantec.com/docs/DOC9776

Appliance Documentation

 

o

S-Series Maintenance and Upgrade Guide 

http://www.symantec.com/docs/DOC9795

 

o

S200 Series Safety and Regulatory Compliance Guide 

http://www.symantec.com/docs/DOC10311

 

o

S400 Series Safety and Regulatory Compliance Guide 

http://www.symantec.com/docs/DOC9996

 

o

S500 Series Safety and Regulatory Compliance Guide 

http://www.symantec.com/docs/DOC10248

CAUTION:  

Before rack-mounting the appliance:

 

o

Power off the appliance and disconnect all cables.

 

o

Verify that the weight of the system does not exceed the rack’s 
fully populated weight limit. For more information, refer to the 
manufacturer’s instructions included with the rack.

 

o

For weight stability, load the rack from the bottom up. 

 

o

Read the “Rack Mount Warnings” section of the 

Safety and 

Regulatory Compliance Guide

.

 

o

Take adequate safety and grounding measures to avoid creating an 
electrical shock hazard and to prevent bodily injury.

Rail_C

Rail_A

Inner Rail (2)

Rail_A (2)

Rail_C (2)

Rail_B (2) 

(used only for 2-post racks)

M3 T-Type Screw (10)

M6 Screw (8)

M6 Cage Nut (8)

(optional)

Rail_C

Locking tab