17. Electrical System
17-4
Battery
Removal
Loosen 1 screw and remove the battery cover.
Disconnect the negative cable terminal first, then
the positive cable terminal.
Remove the battery.
Voltage Check
Use the digital voltmeter to check the voltage of
the battery.
Voltage:
Fully charged: 12.8V
↑
at 20
℃
Undercharged: Below 12.0 V at 20
℃
Warning
y
Keep flames away while recharging.
y
Charging is completely controlled by the
ON/OFF switch on the charger, not by
battery cables.
Charging
Connect the positive terminal (+) of the charger to
the battery positive terminal (+).
Connect the negative terminal (-) of the charger to
the battery negative terminal (-).
Standard
Maximum
Charging current
1.2A
17A
Charging time
10 hr
0.5 hr
Warning
y
Keep flames away while recharging.
y
Charging is completely controlled by the
ON/OFF switch on the charger, not by
battery cables.
Caution
y
Never rapid charge the battery unless in
emergency.
y
Verify the battery is recharged with current
and duration prescribed above.
y
Large current and fast time to charge will
render damage to the battery.
When installing the battery, coat the cable terminal
with grease.
Содержание GTS 250
Страница 1: ...GTS 250 JOYMAX 250 SERVICE MANUAL FORWARD HOW TO USE THIS MANUAL CONTENTS SERIAL NUMBER...
Страница 5: ...Serial Number Home page Contents...
Страница 39: ...2 Maintenance Information 2 18 Note To this chapter contents...
Страница 47: ...3 Lubrication System 3 8 Notes To this chapter contents...
Страница 127: ...10 Alternator Starting Clutch 10 10 Notes To this chapter contents...
Страница 149: ...12 Cooling System 12 14 Notes To this chapter contents...
Страница 175: ...14 Brake System 14 12 Note To this chapter contents...
Страница 215: ...17 Electrical System 17 24 Note To this chapter contents...
Страница 216: ...18 Electrical Diagram 18 1 18 Home page Contents LM25W Electrical Diagram...
Страница 217: ...18 Electrical Diagram 18 2 Note Home page Contents...