Mounting with Pole Mount (NAED 61876): 

 

1. Remove the adjustment bolt located on the pole mount bracket, run the wires through the bracket half that attaches to the fixture.  

2. Install and secure the bracket half to the fixture with the screws provided. (Figure 5). 

3. Remove the screws on other’s half bracket’s side and set aside. Remove the cover plate and set aside. (Figure 5). 

4. Secure to pole: 

•  For square pole 

a. Secure other half of pole mount bracket to square pole with bolts. 

b. Remove the screws on other half’s bracket’s side and set aside. Open the side plate of the pole 

mount accessory, pull the supply wire into the bracket’s junction box. 

c. Join the two bracket parts and re-install the adjustment bolt securing both pieces of the bracket 

together, thus attaching the fixture to the pole. 

d.  Make all wiring connections via the supplied wire leads in accordance with NEC and local codes 

and pull the wires completely into bracket’s junction box and making appropriate electrical 

connections. 

e. Re-install the bracket’s side cover plate and secure with the previously removed screws (Figure 8). 

•  For round pole 

a. Remove silicon plate from the pole mounting bracket (Figure 9). 

b. Secure other half of pole mount bracket to square pole with bolts. 

c. Remove the screws on other’s half bracket’s side and set aside. Open the side plate of the pole 

mount accessory, pull the supply wire into the bracket’s junction box. 

d. Join the two bracket parts and re-install the adjustment bolt securing both pieces of the bracket 

together, thus attaching the fixture to the pole. 

e.  Make all wiring connections via the supplied wire leads in accordance with NEC and local codes 

and pull the wires completely into bracket’s junction box and making appropriate electrical 

connections. (Figure 7). 

f.  Re-install the bracket’s side cover plate and secure with the previously removed screws. 

 

5. The pole mounting bracket allows the luminaire to be adjusted up to 35° above horizontal (Figure 7). Loosen the adjustment 

bolt and adjust tilt as needed and tighten adjustment bolt to lock in place. 

 

     

 

 

 

 

 

Figure 5  

 

 

 

 

Figure 6 

 

 

 

 

                Figure 7 

 

 

    Figure 8 

 

 

          Figure 9 

Содержание ValueLED 61875

Страница 1: ...R TO TEST THE LUMINAIRE PLEASE ABIDE BY ALL RELEVANT NATIONAL STATE AND MUNICPAL SAFETY CODES WHEN INSTALLING THIS FIXTURE TO AVOID SHOCK PLEASE DO NOT ATTEMPT INSTALLATION DURING RAIN INSTALLATIONS S...

Страница 2: ...seal the shorting cap or photocontrol MIN 75 C SUPPLY CONDUCTOR THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BAY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPER...

Страница 3: ...secure with the screws provided Figure 2 3 Loosen the four locking bolts on slipfitter bracket make all wiring connections via the supplied wire leads in accordance with NEC and local codes and pull t...

Страница 4: ...d making appropriate electrical connections e Re install the bracket s side cover plate and secure with the previously removed screws Figure 8 For round pole a Remove silicon plate from the pole mount...

Страница 5: ...t bolt to lock in place Figure 10 Figure 11 Figure 12 Distances 3 03 OC between 2 0 39 holes 1 52 OC between 0 39 hole 0 79 hole Figure13 Mounting with Trunnion Mount NAED 61878 1 Run the fixture wire...

Страница 6: ...st appropriate hardware for the desired mounting location See figure 21 for the mounting pattern 4 The yoke mounting bracket allows the luminaire to be adjusted up and down Loosen the screws on both s...

Страница 7: ...sensor s settings remove the motion sensor cover by loosening it s screws Set the motion sensor s settings via the DIP switches as per actual requirements Replace the motion sensor cover and secure by...

Страница 8: ...3983099...

Страница 9: ...UR TESTER CE LUMINAIRE VEUILLEZ RESPECTER TOUTES LES EXIGENCES DES CODES NATIONAUX PROVINCIAUX ET MUNICIPAUX APPLICABLES LORS DE L INSTALLATION DU LUMINAIRE POUR VITER LES CHOCS LECTRIQUES VITER D INS...

Страница 10: ...ptacle pour sceller la fiche de mise en court circuit ou la cellule photo lectrique MIN 75 C SUPPLY CONDUCTOR THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BAY A P...

Страница 11: ...oulons de verrouillage du support raccord lisse effectuer toutes les connexions de c blage l aide des fils inclus et en respectant les exigences du Code de l lectricit national NEC et des codes locaux...

Страница 12: ...en effectuant les connexions lectriques requises e R installer la plaque du couvercle lat rale et rattacher avec les vis retir es pr c demment Figure 8 Pour un m t rond a Retirer la plaque de silicone...

Страница 13: ...e pour verrouiller en position Figure 10 Figure 11 Figure 12 Distances 3 03 au centre entre 2 trous de 0 39 po 1 52 po au centre entre le trou de 0 39 po et celui de 0 79 po Figure13 Installation avec...

Страница 14: ...ent de montage d sir Pour la configuration de montage vous reporter la figure 21 4 Le support de montage avec trier permet d ajuster le luminaire vers le haut et vers le bas Desserrer les vis sur les...

Страница 15: ...de des interrupteurs DIP pour r pondre aux exigences actuelles Replacer le couvercle du capteur de mouvement et rattacher l aide des vis Sch ma du capteur de mouvement R glages de l interrupteur DIP L...

Страница 16: ...s allumer sous un seuil de luminosit ambiante d fini En mode de d sactivation le capteur de lumi re du jour allume la lampe lorsque le mouvement est d tect peu importe le niveau d clairage ambiant 50...

Отзывы: