Sylvania SRM910-33ECN Скачать руководство пользователя страница 4

4

FIREPLACE INSERT INSTALLATION

The fireplace insert can be installed after the mantel has been fully assembled.

WARNING:

 Make sure the fireplace insert controls are in the OFF position and the 

unit is NOT plugged in.

Step 1: Carefully place the INSERT in the unit opening.  The front of INSERT should be 
flush with the front of the mantel.  Carefully lift the INSERT into the mantel until the 
top stopper is against the mantel.

Step 2: Attach 3 Mounting Clips [U] to the top side of insert with 3 Short KD screws [T]. 
Attach 2 Mounting Brackets [V] to the bottom of insert with 2 Short KD screws [T]. See 
Fig F.

Fig. F     

Step 3: Move assembled unit to desired location. Unit should not be positioned in area 
exposed to direct sunlight.

OPERATION

After reading complete instructions, confirm all controls on fireplace are in the OFF 
position. Plug the fireplace into a 15AMP/120Volt outlet. If the cord does not reach, you 
may use an extension cord rated for a minimum of 1875 WATTS. Once the fireplace in-
sert has been properly connected to a grounded electrical outlet, it is ready to operate.

OPERATION BY THE CONTROL PANEL 

The controls are located behind the 2 front covers at the top right and left corners of 
the insert, and can be accessed by gently pushing the bottom of the covers.

O/I: 

Press this button for main power and flame effect. The indicator light will turn on. 

See below for other control switches.

750W:

 For low heat function - Press this switch while the 

O/I

 switch is in the on  

position for low heat. The indicator light will turn on.

1500W: 

For high heat function - Press this switch while the 

O/I

 switch  and the 750W 

switch are in the on position for high heat. The indicator light will turn on.

Temperature Control:

 To adjust the temperature to your individual requirements, 

turn the temperature control dial to the right (clockwise) to increase the desired tem-
perature and to the left for lower temperature. This temperature control dial can only 
be used while the 

O/I

 switch and 750W & 1500W switches are in the ON position.

Dimmer Control Knob:

 Turn the dimmer dial clockwise or counter clockwise to get 

the desired flame intensity. The dimmer switch can only be used when the 

O/I

 switch 

is in the on position.

Note:

 When the 

O/I

 switch is turned off, all other heater functions will stop even 

though the switches may be in the on position. 

MAINTENANCE

Disconnect power and unplug the power cord before attempting any maintenance or 
cleaning to reduce the risk of fire, electric shock or damage to persons. The bulbs in 
your unit can become extremely hot. Allow at least 10 minutes between turning off the 
unit and removing the light bulbs to avoid the accidental burning of the skin.

risk OF FirE: dO NOt ExcEEd tHE rEcOMMENdEd bulb wattagE. 

REPLACING THE FLAME EFFECT LIGHT  

AND LOG-SET LIGHT BULBS

Step 1:  Remove the 2 screws on the front of the fireplace and open the glass window.
Step 2:  Remove the screws from both sides of the log set bed.
Step 3:    Remove the log set bed. You will find 2 x 40 Watt type E-12 bulbs.
Step 4:  Loosen, remove  and replace the burnt out bulb(s)
Step 5:   Set the log set bed back into place and re-attach the screws.
Step 6:  Close the glass window and re-attach the screws.
Step 7:  Plug in the unit.

Содержание SRM910-33ECN

Страница 1: ...lace turn controls to off then remove plug from outlet 10 Connect to properly grounded outlets only 11 Do not insert or allow foreign objects to enter any ventilation or exhaust open ing as this may cause an electric shock or fire or damage the heater 12 To prevent a possible fire do not block air intakes or exhaust in any manner Do not use on soft surfaces like a bed where openings may become blo...

Страница 2: ...1 hour to complete TOOL REQUIRED PHILLIPS HEAD SCREWDRIVER MANTEL ASSEMBLY CAUTION Place a piece of cardboard or protective sheet on the floor in order to avoid scratching the decorative surface of your mantle during assembly Please DO NOT fully tighten the KD screws until all panels are assembled NOTE Each Plastic Connector is pre assembled pre drilled on the specific panels with 2 screws If the ...

Страница 3: ...t front panel D and Left side panel F to Base B with 3 KD screws Attach Right front panel E and Right side panel G to Base B with 3 KD screws See Fig C Fig C Step 4 Attach Upper front panel C to Left and Right front panel D and E with 4 KD screws See Fig D Fig D Step 5 Attach Top panel A to the unit as shown in Fig E with 3 KD screws See Fig E Fig E Step 6 Tighten all KD SCREWS ...

Страница 4: ...icator light will turn on 1500W For high heat function Press this switch while the O I switch and the 750W switch are in the on position for high heat The indicator light will turn on Temperature Control To adjust the temperature to your individual requirements turn the temperature control dial to the right clockwise to increase the desired tem perature and to the left for lower temperature This t...

Страница 5: ...es before you start drilling Option 1 Use the spare KD NUTS KD SCREWS and PLASTIC CONNECTOR 1 Place the PLASTIC CONNECTOR on the mantel unit and mark the drill holes as shown in Fig B Fig B 2 Drill the holes with diameter 3 4 inches 10 mm and depth 3 4 inches 10mm on the mantel Each Plastic Connector needs 3 holes See Fig C Fig C Fig D 3 Gently install the KD NUTS into the drilled holes with hamme...

Страница 6: ...c fireplace heater is tested before it leaves the factory and it is guaran teed for one year If the unit should fail to operate correctly within one year from the date of purchase call customer service at 1 800 459 4409 EST We will at our discretion either repair or replace the unit It will have to be returned to us freight prepaid and we will return the repaired or replaced unit to you freight pr...

Отзывы: