OPERATION BY THE REMOTE CONTROL
Plug in your electric fireplace heater and it will beep once, this means you have power
and your remote is ready to operate your electric fireplace heater.
: Standby switch. Press this switch once the unit becomes energized and you can
select the following functions as desired. Press this switch again, the unit will be
OFF and enter standby mode.
:
Press this button once for flame effect. The unit will be beep and the indicator
light will be ON. The bulbs for flame effect will turn ON. To adjust the flame
intensity, hold down the button - the flame optics will go higher or lower. Once
you have found the desired setting, release the button. Pressing the button
again will stop the light function.
750W:
Press this button for low heat level. The unit will beep, the pilot light and
indicator light will be on. The electric fireplace heater will give low heat level. Pressing
once again will stop the low heat level function.
1500W:
Press this button for high heat level. The unit will beep, the pilot light and
indicator light will be on. The electric fireplace heater will give high heat level. Pressing
once again will stop the high heat level function.
REMOTE CONTROL BATTERY REPLACEMENT
Replace with 2 AAA batteries.
warNiNg:
Do not mix old and new batteries. Do not mix alkaline, standard (Carbon-Zinc), or
rechargeable (Nickel Cadmium) batteries.
MAINTENANCE
warNiNg
: Disconnect power and unplug the power cord before attempting
any maintenance or cleaning to reduce the risk of fire, electric shock or damage
to persons. The bulbs in your unit can become extremely hot. Allow at least 10
minutes between turning off the unit and removing the light bulbs to avoid the
accidental burning of the skin.
risk OF FirE: dO NOt ExcEEd tHE rEcOMMENdEd bulb wattagE.
REPLACING THE LIGHT BULBS
Step 1: Remove the front cover by pulling it upward until the front cover has been
removed from the 4 locking posts located at 2 sides. See Fig. E.
fig. E
Step 2: Then remove the rock bed from the fireplace. See Fig. F.
fig. F
Step 3: Remove the lower cover by loosening 11 screws as shown in Fig. G. You will
find 3 x 40 watt type B-10 bulbs.
fig. G
Step 4: Loosen and remove burnout bulb(s) and replace with new bulb(s).
Step 5: Replace the lower cover and re-attach all the 11 screws.
Step 6: Replace the rock bed.
Step 7: Hold the front cover tightly and engage it with the 4 locking posts at 2 sides of
the fireplace. Make sure the front cover has been completely put into ALL 4
locking posts before release your hands.