![Sylvania SGCVT-500 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/sylvania/sgcvt-500/sgcvt-500_instruction-manual_1417542002.webp)
2
Fig. 1
WIDTH OF CONVECTOR
15.3 cm
(6 in)
15.3 cm
(6 in)
Minimum
clearance to
adjacent
surface
15.3 cm
(6 in)
Minimum
clearance to
adjacent
surface
Minimum
distance
to ground
A
B
D
C
E
E
model
a
(cm)
b
(cm)
C
(cm)
d
(cm)
e
(cm)
SGCVT-500
44.6
34.0
4.5
6.2
20.8
SGCVT-1000
53.7
33.7
12.2
7.8
24.8
SGCVT-1500
58.1
33.7
9.8
14.6
22.2
SGCVT-2000
72.6
48.3
11
13.2
22.2
WALL MOUNTING INSTRUCTIONS
1. Release the mounting bracket by pressing the locking brackets on both sides.
2. Use the mounting bracket as a template by holding it against the wall as
illustrated in Fig. 1.
3. Follow the dimensions specified in Fig. 1 and place mounting bracket in the
desired location.
4. Mark the 4 screw holes. Place mounting bracket on the screw markings and
ensure the mounting bracket is perfectly level.
5. Predrill holes and insert 4 wall anchors. Wall anchors are needed for
mounting on drywall or concrete walls. Ensure you use the proper anchors
for your wall type.
6. Replace the mounting bracket and fasten it with screws (minimum 4 screws).
7. Mount the convector to the mounting bracket and engage the 2 locking
brackets at the top. See Fig. 2.
Caution – high temPerature, risk of fire. keeP eleCtriCal
Cords, draPery, furnishings and other Combustibles at least
3 ft (0.9 m) away from the front of the heater and away from
the side and rear of heater.
warning – to reduCe risk of fire, do not store or use
gasoline or other flammable vaPors and liQuids in the
viCinity of the heater.
Fig. 2
Mur
Support mural
Convecteur
ELECTRICAL WIRING
warning: this ConveCtion heater is to be used on a 240
vaC
Power suPPly and grounded outlets.
THERMAL CUT-OFF
PROTECTION
HEATER
LCD
BLACK (L)
WHITE (N)
SENSOR
GREEN/YELLOW (G)
Caution: turn off main Power before beginning installation
to avoid eleCtriC shoCk.
WARNING: THE HEATER MUST bE INSTALLEd bY A
CERTIFIEd ELECTRICIAN ANd IN ACCORdANCE WITH
ALL LOCAL ANd NATIONAL ELECTRICAL COdES.
1. Connect white colored neutral wire (N).
2. Connect black colored live wire (L).
3. Connect green colored ground wire. All connections using twist on wire
connectors. Put all wires properly into the junction box before replacing the
cover with the provided screw.
OPERATION
1. Confirm that the heater is turned on at the main switch panel (circuit breaker).
2. After switching on, the thermostat will start at the default temperature,
40 degrees Celsius.
3. There are 3 control buttons:
uP
– Temperature Up
down
– Temperature Down
°C / °f
– Change temperature to Celsius or Fahrenheit
4. In Celsius mode, pressing the UP or DOWN once will increase / decrease the
temperature in 0.5 degree C increments. In Fahrenheit mode, press the UP or
DOWN button once will increase the temperature in 1.0 degree F increments.
5. Pressing the UP or DOWN buttons continuously will increase / decrease the
temperature setting quickly.
6. Once the temperature control buttons are set and released, the display will
change from the temperature to the room temperature after a few seconds.
7. The LED display 3 digits. In Celsius Mode, the temperature will display with
one decimal, e.g. 22.5; for Fahrenheit, there is no decimal, e.g. 104 deg F will
display as 104. The heater shall be turned OFF at the main switch panel (or
circuit breaker) in summer time.
8. In the summer or whenever the convection heater will not be used for an
extended period of time, turn OFF the convector at the main switch panel (or
circuit breaker).