Sylvania SGCVT-500 Скачать руководство пользователя страница 2

2

Fig. 1

WIDTH OF CONVECTOR

15.3 cm

(6 in)

15.3 cm

(6 in)

Minimum

clearance to 

adjacent 

surface

15.3 cm

(6 in)

Minimum

clearance to 

adjacent 

surface

Minimum

distance 

to ground

A

B

D

C

E

E

model

a

 (cm)

b

 (cm)

C

 (cm)

d

 (cm)

e

 (cm)

SGCVT-500

44.6

34.0

4.5

6.2

20.8

SGCVT-1000

53.7

33.7

12.2

7.8

24.8

SGCVT-1500

58.1

33.7

9.8

14.6

22.2

SGCVT-2000

72.6

48.3

11

13.2

22.2

WALL MOUNTING INSTRUCTIONS

1.  Release the mounting bracket by pressing the locking brackets on both sides.
2.  Use the mounting bracket as a template by holding it against the wall as 

illustrated in Fig. 1.

3.  Follow the dimensions specified in Fig. 1 and place mounting bracket in the 

desired location.

4.  Mark the 4 screw holes. Place mounting bracket on the screw markings and 

ensure the mounting bracket is perfectly level. 

5.  Predrill holes and insert 4 wall anchors. Wall anchors are needed for 

mounting on drywall or concrete walls. Ensure you use the proper anchors 
for your wall type.

6.  Replace the mounting bracket and fasten it with screws (minimum 4 screws).
7.  Mount the convector to the mounting bracket and engage the 2 locking 

brackets at the top. See Fig. 2.

Caution – high temPerature, risk of fire. keeP eleCtriCal 

Cords, draPery, furnishings and other Combustibles at least 

3 ft (0.9 m) away from the front of the heater and away from 

the side and rear of heater.

warning – to reduCe risk of fire, do not store or use 

gasoline or other flammable vaPors and liQuids in the 

viCinity of the heater.

Fig. 2

Mur

Support mural

Convecteur

ELECTRICAL WIRING

warning:  this ConveCtion heater is to be used on a 240

 

vaC 

Power suPPly and grounded outlets.

THERMAL CUT-OFF

PROTECTION

HEATER

LCD

BLACK (L)

WHITE (N)

SENSOR

GREEN/YELLOW (G)

Caution: turn off main Power before beginning installation 

to avoid eleCtriC shoCk.

WARNING: THE HEATER MUST bE INSTALLEd bY A 

CERTIFIEd ELECTRICIAN ANd IN ACCORdANCE WITH 

ALL LOCAL ANd NATIONAL ELECTRICAL COdES.

1.  Connect white colored neutral wire (N).
2.  Connect black colored live wire (L).
3.  Connect green colored ground wire. All connections using twist on wire 

connectors. Put all wires properly into the junction box before replacing the 
cover with the provided screw.

OPERATION

1.  Confirm that the heater is turned on at the main switch panel (circuit breaker).
2.   After switching on, the thermostat will start at the default temperature,  

40 degrees Celsius.

3.   There are 3 control buttons:

  

uP

 

–  Temperature Up

  

down

  –  Temperature Down

  

°C / °f

  –  Change temperature to Celsius or Fahrenheit

4.   In Celsius mode, pressing the UP or DOWN once will increase / decrease the 

temperature in 0.5 degree C increments. In Fahrenheit mode, press the UP or 
DOWN button once will increase the temperature in 1.0 degree F increments.

5.   Pressing the UP or DOWN buttons continuously will increase / decrease the 

temperature setting quickly.

6.   Once the temperature control buttons are set and released, the display will 

change from the temperature to the room temperature after a few seconds.

7.   The LED display 3 digits. In Celsius Mode, the temperature will display with 

one decimal, e.g. 22.5; for Fahrenheit, there is no decimal, e.g. 104 deg F will 
display as 104. The heater shall be turned OFF at the main switch panel (or 
circuit breaker) in summer time.

8.  In the summer or whenever the convection heater will not be used for an 

extended period of time, turn OFF the convector at the main switch panel (or 
circuit breaker).