background image

5

Fig. M

Fig. Mm

Step 14:  Attach corner panel to Top panel [A] with 6 mounting screws (T). See fig. N  

Fig. N

Step 15:  Attach 4 panel P into the unit as shown in Fig. O.

Fig. O

Step 16:  Attach 4 Door hinges to Left and Right Door [Q and R] with 8 mounting 
screws [T] (2 screws for each hinge) as shown in Fig Pp.  Attach Left and Right Door [Q 
and R] to Panel C and D with 8 mounting screws [T] (2 screws for each hinge). See Fig. 
P.  Attach Door handles [Rs] to Left and Right Door with 2 Door screws [Rt].  
  

 

Fig. P

Fig. Pp

Step 17: Tighten all KD SCREWS.

FIREPLACE INSERT INSTALLATION:

 
The fireplace insert can be installed after the mantel has been fully assembled.

WARNING:

 Make sure the fireplace insert controls are in the OFF position and the 

unit is NOT plugged in.

  

     

Содержание SBM902CM-42FDC

Страница 1: ...fireplace turn controls to off then remove plug from outlet 10 Connect to properly grounded outlets only 11 Do not insert or allow foreign objects to enter any ventilation or exhaust open ing as this...

Страница 2: ...up repair paint bottle L shape bracket 2 Screws for L bracket 8 Plastic connectors 1 KD screws 3 KD nuts 3 TOOL REQUIRED PHILLIPS HEAD SCREWDRIVER MANTEL ASSEMBLY CAUTION Place a piece of cardboard o...

Страница 3: ...D to Base panel B with 4 KD screws See Fig C Fig C Step 4 Attach panel F to Base panel B with 1 KD screw See fig D Fig D Step 5 Attach panel G to panels D and F with 4 KD screws See fig E Fig E Step...

Страница 4: ...K with 2 KD screws See fig I Fig I Step 10 Attach panel K to panel E and F with 4 KD screws See fig J Fig J Step 11 Attach panel J to panel K with 2 KD screws See fig K Fig K Step 12 Attach panel N an...

Страница 5: ...ch hinge as shown in Fig Pp Attach Left and Right Door Q and R to Panel C and D with 8 mounting screws T 2 screws for each hinge See Fig P Attach Door handles Rs to Left and Right Door with 2 Door scr...

Страница 6: ...trol To adjust the temperature to your individual requirements turn the temperature control dial to the right clockwise to increase the desired temperature and to the left for lower temperature This t...

Страница 7: ...s before you start drilling Option 1 Use the spare KD NUTS KD SCREWS and PLASTIC CONNECTOR 1 Place the PLASTIC CONNECTOR on the mantel unit and mark the drill holes as shown in Fig B Fig B 2 Drill the...

Страница 8: ...fireplace heater is tested before it leaves the factory and it is guaranteed for one year If the unit should fail to operate correctly within one year from the date of purchase call customer service...

Отзывы: