background image

Catalog # 

Date 

Type

Project 

Prepared by 

Comments 

SPECIFICATION DATA

P

O

W

ER

S

EN

S

C

O

N

TR

O

LS

 

Fluorescent 

 

 

 

Building 

Controls  

Powerline 

0-10 VDC 

Photo  

Occupancy  

Management

Manufacturer 

Controllers 

Controllers 

Cells 

Sensors 

Systems

SYLVANIA ELOGIC

 Controls

1-800-LIGHTBULB 

www.sylvania.com

 

x

Hunt Dimming 

970-484-9048 

www.huntdimming.com 

x

Lehigh Electronic Products 

610-395-3386 

www.lehighdim.com 

x

Leviton Lighting Controls 

800-824-3005 

www.leviton.com 

Lightolier Controls 

800-526-2731 

www.lolcontrols.com 

x

Lithonia Controls 

800-533-2719 

www.lithonia.com 

x

Lumisys 

800-241-9173 

www.lumisys1.com 

 

 

x

PCI 

800-767-3674 

www.pcilightingcontrols.com 

 

 

Sensorswitch 

1-800-PASSIVE 

www.sensorswitch.com 

 

 

x

Siemens Energy & Automation 

800-427-2256 

www.sea.siemens.com 

 

 

 

 

x

Starfield Controls 

303-427-1661 

www.starfieldcontrols.com 

 

x

The Watt Stopper, Inc 

800-879-8585 

www.wattstopper.com 

 

 

Please contact controls manufacturers to order/specify controls. For the latest controls list go to www.sylvania.com
Also for more information, check out the LCA (Lighting Controls Association) site: www.aboutlightingcontrols.org

Control Specifications/model numbers may change.  

Please consult manufacturers listed for their latest control models and to order their controls.

WARNING:

Install and wire these ballast and controls in accordance with the National Electrical Code (NEC), all applicable Federal, State 
and local electrical codes, as well as the specific instructions provided with the compatible control that you purchased. 
Installation should be performed by qualified personnel only.
These instructions are guidelines only. Installation may vary for different controls/fixtures/applications. Be sure to follow the 
control instructions and all applicable codes and standards when installing dimming systems.

Please contact controls manufacturer listed in the OSRAM SYLVANIA Inc. controls cross reference for compatible 
controls and instruction wiring
NOTES:  1. Dimming ballasts source < 0.5mA (0-10VDC control input).  

2. Powerline controls must be rated for the type (e.g. Fluorescent Phase-control) and size  
(e.g. 600W, 1000W, 1500W & 2000W etc.) of the connected load. Do NOT use incandescent powerline controls; 
incandescent dimmers are not rated for fluorescent loads and are NOT compatible with POWERSENSE ballasts. 

QUICKTRONIC

®

 POWERSENSE

®

 Controls Information 

Contact the companies listed for their 
2-wire Fluorescent/Powerline controls 
and/or 0-10V controls information.

T5 POWERSENSE Dimming Ballast
50726 QTP 2x28T5/UNV DIM-TCL

T5 

POWERSENSE

High Efficiency 

OSRAM SYLVANIA  
National Customer  
Service and Sales Center

1-800-LIGHTBULB  
(1-800-544-4828)
www.sylvania.com

Specifications subject to change without notice.

Controls Guide

Отзывы: