PAGE 1 OF 2 COPYRIGHT GERARD LIGHTING ABN 71 115 184 999 Vi2015
Gerard Lighting Pty Ltd
96-112 Gow Street, Padstow, NSW 2211
T: 02 9794 9300 |
www.gerardlighting.com.au
INSTALLATION / WARRANTY INSTRUCTIONS
issue date: 01/04/2016
PRODUCT BRAND
- Sylvania
PRODUCT NAME / CODES
- Sylvania Briteline LED Raptor – SR4H757A2
PLEASE READ THESE INSTALLATION INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR MAINTAINING THIS
EQUIPMENT. THE PRODUCT IS DESIGNED FOR INSTALLATION AND MAINTENANCE IN ACCORDANCE WITH
RELEVANT AUSTRALIAN STANDARDS (AS3000) AND LOCAL REGULATIONS (WHERE APPLICABLE), BY AN
AUTHORISED AND LICENCED ELECTRICIAN. THE INSTALLATION INSTRUCTIONS WERE CORRECT AT THE TIME OF PRINT.
TO REFLECT CHANGES IN TECHNOLOGY AND AUSTRALIAN STANDARDS; GERARD LIGHTING RESERVES THE RIGHT TO AMEND
THE INSTRUCTIONS WITHOUT NOTICE. UPDATED GUIDELINES CAN BE FOUND ON THE RELEVANT BRAND WEB SITE.
IMPORTANT - THE PRODUCT MUST BE MAINTAINED AND OPERATED IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS, FAILURE TO DO SO MAY DAMAGE THE PRODUCT AND SERVICES. IT IS STRONGLY RECOMMENDED THAT THIS
IMPORTANT NOTE BE COMMUNICATED TO THE OWNER AND OR OPERATOR OF THE INSTALLATION AT THE TIME OF SITE
COMMISSIONING. GOOD PRACTICE DOES NOT RECOMMEND THE 24/7 USE OF PRODUCTS WITHOUT THE APPLICATION OF
SUITABLE SWITCH CYCLE INTERVALS. FURTHERMORE, WITH THE OMISSION OF NOMINATED SURVIVAL CURVES AND OR
RECOMMENDED OPERATING HOURS, PRODUCT DESIGN EXPECTATIONS PROVIDE FOR A CONTINUAL DAILY USAGE OF 6 HOURS
FOR RESIDENTIAL APPLICATIONS AND A CONTINUAL DAILY USAGE OF 12 HOURS FOR COMMERCIAL AND INDUSTRIAL
APPLICATIONS. ALL PRODUCTS MUST BE THOROUGHLY CLEANED ON A REGULAR BASIS AT INTERVALS THAT REFLECT IN THE
INSTALLATION ENVIRONMENT, ENSURING THE OPTICAL PERFORMANCE, TOGETHER WITH THE ELECTRICAL, MECHANICAL AND
STRUCTURAL INTEGRITY AS DESIGNED, IS MAINTAINED THROUGHOUT THE SERVICE LIFE OF THE PRODUCT.
For the latest product online reference data,
simply install and activate a QR code
scanner application on your smartphone.
For more information refer brand web.
1. PRODUCT SPECIFICATION:
240V System
415V System
Product brand
- Sylvania
-Sylvania
Type of Protection
- Class I
- Class I
IP Rating - for interior products, the IP rating nominated
is “from below the ceiling” unless specifically nominated.
- IP66
- IP66
Nominal design Voltage
- 240V
- 415V
Circuit wattage
- 1260W
- 1260W
Line current
- 5.5A,
- 3.2A
Important – when installing electronic or HID lighting equipment, the installer must consider the In-rush start current (if any) as
documented on the control gear identification label when selecting appropriate circuit controls or protective devices.
Power factor
- 0.9
-0.9
Nominal Freq. (Hz)
- 50 Hz
-050Hz
Rated Minimum / Maximum Ambient Temperature
- -10°C / 40°C
- -10°C / 40°C
Suitable for direct mounting on flammable surfaces
- NO
- NO
Dimmable (if relevant refer brand web for approved list)
- YES 0-10V Analogue - YES 0-10V Analogue
Installation orientation
- -10 deg to +60 deg on the horizontal
Designed application
- Exterior use, Insterior on GL approval
Rated average design life
- 36000hrs @ L90
2. APPROVALS: The RCM marking of this product applies to AS/NZS CISPR15 (EMC) “Limits and methods of
measurement of radio disturbance characteristics of electrical lighting and similar equipment”. This
product is designed to conform to AS/NZS60598 “Luminaires, general requirements and tests”.
3. STORAGE: Prior to installation products are to be stored in cool and dry conditions.
4. APPLICATION: The installation application and orientation of the product is designed in accordance with the nominated
product IP rating, class designation and these installation instructions. Installation environments and operating conditions
beyond these instructions are not recommended.
5. INSTALLATION / GENERAL: Installation of the product is to be completed by an authorized and licensed electrician, in
accordance with these instructions, relevant Australia standards and local regulations (where applicable). Termination of product
wiring, together with the installation of the product must be in a manner and orientation that maintains the integrity of the
designated IP rating of the product For electronic control equipment (when supplied) DO NOT MEGGER between A and N.
QR CODE
PLACEMENT
IF AVAILABLE
PAGE 1 OF 2 COPYRIGHT GERARD LIGHTING ABN 71 115 184 999 Vi2015
Gerard Lighting Pty Ltd
96-112 Gow Street, Padstow, NSW 2211
T: 02 9794 9300 |
www.gerardlighting.com.au
INSTALLATION / WARRANTY INSTRUCTIONS
issue date: 01/04/2016
PRODUCT BRAND
- Sylvania
PRODUCT NAME / CODES
- Sylvania Briteline LED Raptor – SR4H757A2
PLEASE READ THESE INSTALLATION INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR MAINTAINING THIS
EQUIPMENT. THE PRODUCT IS DESIGNED FOR INSTALLATION AND MAINTENANCE IN ACCORDANCE WITH
RELEVANT AUSTRALIAN STANDARDS (AS3000) AND LOCAL REGULATIONS (WHERE APPLICABLE), BY AN
AUTHORISED AND LICENCED ELECTRICIAN. THE INSTALLATION INSTRUCTIONS WERE CORRECT AT THE TIME OF PRINT.
TO REFLECT CHANGES IN TECHNOLOGY AND AUSTRALIAN STANDARDS; GERARD LIGHTING RESERVES THE RIGHT TO AMEND
THE INSTRUCTIONS WITHOUT NOTICE. UPDATED GUIDELINES CAN BE FOUND ON THE RELEVANT BRAND WEB SITE.
IMPORTANT - THE PRODUCT MUST BE MAINTAINED AND OPERATED IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS, FAILURE TO DO SO MAY DAMAGE THE PRODUCT AND SERVICES. IT IS STRONGLY RECOMMENDED THAT THIS
IMPORTANT NOTE BE COMMUNICATED TO THE OWNER AND OR OPERATOR OF THE INSTALLATION AT THE TIME OF SITE
COMMISSIONING. GOOD PRACTICE DOES NOT RECOMMEND THE 24/7 USE OF PRODUCTS WITHOUT THE APPLICATION OF
SUITABLE SWITCH CYCLE INTERVALS. FURTHERMORE, WITH THE OMISSION OF NOMINATED SURVIVAL CURVES AND OR
RECOMMENDED OPERATING HOURS, PRODUCT DESIGN EXPECTATIONS PROVIDE FOR A CONTINUAL DAILY USAGE OF 6 HOURS
FOR RESIDENTIAL APPLICATIONS AND A CONTINUAL DAILY USAGE OF 12 HOURS FOR COMMERCIAL AND INDUSTRIAL
APPLICATIONS. ALL PRODUCTS MUST BE THOROUGHLY CLEANED ON A REGULAR BASIS AT INTERVALS THAT REFLECT IN THE
INSTALLATION ENVIRONMENT, ENSURING THE OPTICAL PERFORMANCE, TOGETHER WITH THE ELECTRICAL, MECHANICAL AND
STRUCTURAL INTEGRITY AS DESIGNED, IS MAINTAINED THROUGHOUT THE SERVICE LIFE OF THE PRODUCT.
1. PRODUCT SPECIFICATION: Luminaire head only – Control gear refer additional instruction manual
Product brand
- Sylvania
Product weight
- 28.6Kgs
Type of Protection
- Class I
IP Rating - for interior products, the IP rating nominated
is “from below the ceiling” unless specifically nominated.
- IP66
Important – when installing electronic or HID lighting equipment, the installer must consider the In-rush start current (if any) as
documented on the control gear identification label when selecting appropriate circuit controls or protective devices.
Voltage
- 130 – 150V DC per channel
Current
- 2.1 - 2.2A per channel
Rated Minimum / Maximum Ambient Temperature
- 0°C / 40°C
Suitable for direct mounting on flammable surfaces
- NO
Dimmable
- Refer compatible control gear
Installation orientation
- -10 deg to +60 deg on the horizontal refer page 5
Designed application
- Exterior use only: Refer Section 6A
Rated average design life
- 36000hrs @ L90
Minimum distance from lit objects
- 5m
2. APPROVALS: The RCM marking of this product applies to AS/NZS CISPR15 (EMC) “Limits and methods of
measurement of radio disturbance characteristics of electrical lighting and similar equipment”. This
product is designed to conform to AS/NZS60598.1:2013 “Luminaires, general requirements and tests”,
AS/NZS60598.2.5:2002“Luminaires - Particular requirements – Floodlights”
3. STORAGE: Prior to installation products are to be stored in cool and dry conditions.
4. APPLICATION: The installation application and orientation of the product is designed in accordance with the nominated
product IP rating, class designation and these installation instructions. Installation environments and operating conditions
beyond these instructions are not recommended.
5. INSTALLATION / GENERAL: Installation of the product is to be completed by an authorized and licensed electrician, in
accordance with these instructions, relevant Australia standards and local regulations (where applicable). Termination of product
wiring, together with the installation of the product must be in a manner and orientation that maintains the integrity of the
designated IP rating of the product For electronic control equipment (when supplied) DO NOT MEGGER between A and N.
6. INSTALLATION / SPECIAL CONDITIONS (relevant only for products approved for such an installation):
(a) products installed in high wind environments must have suitable installation / fastening methods applied to ensure the
product’s mounting points are not damaged through, corrosion, constant vibration and or movement. Exterior products are
designed with precise vertical aiming limits, which should not be exceeded. Any vertical floodlight aiming requirements should