10-15
TP402
+13V
TP403
TP1802
FR
TP1803
A-GND
TP1801
FL
TP1805
DVD-Y
TP1806
CHROMA
TP1804
GND
BL3150F01011-1
Main CBA Top View
For continued protection against risk of fire,
replace only with same type 4 A, 125V fuse.
CAUTION ! :
ATTENTION :
Utiliser un fusible de rechange de m
ê
me type de 4A, 125V.
4A/125V
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F601) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Because a hot chassis ground is present in the power
supply circuit, an isolation transformer must be used.
Also, in order to have the ability to increase the input
slowly,when troubleshooting this type power supply
circuit, a variable isolation transformer is required.
Содержание 6615LDF
Страница 1: ...SERVICE MANUAL 15 LCD TV DVD 6615LDF...
Страница 41: ...10 8 L3150SCF Function Schematic Diagram...
Страница 45: ...10 12 DVD Main 2 3 Schematic Diagram L3150SCD2...
Страница 50: ...10 17 Function CBA Top View Function CBA Bottom View BL3150F01011 2...
Страница 67: ...6615LDF L3150UA 2005 06 30...