12
(J) Rectangular dry brush + (K) Round dry brush
These two brushes should be used when you just want to vacuum. The choice between
the two depends on the spots to be cleaned.
(L) Funnel
This is a useful accessory for refilling the boiler with water through the refill tank.
(N)+(O)Iron: use
An iron can be connected to the appliance slalom system, for professional ironing.
Plug the iron into the slalom system. Ref. 7 and 8 page 2.
Activate the ironing function: press first the motor push button and after a short buzzer,
the iron is ready. Select the temperature desired by acting on the adjustment knob Ref. C
An orange light on the side of the iron will turn on. Wait until it turns off. (the iron is ready
for use). To enable vapour release, press the button ref. D
Deactivate the ironing function: When you have terminated ironing, before disconnec-
ting the iron plug from the machine body, press the motor push button.
WARNING:
Some parts of the iron reach very high temperatures. DO NOT TOUCH.
The steam hose Ref A must not come into contact with the iron plate or any sharp
or pointed objects.
Only replace the iron onto the silicon mat Ref. B Never leave the iron unguarded
when it is connected to the appliance.
WARNINGS
The mat Ref. B coded D0012, cannot be sold separately
and must only be used with the iron included in the package.
IMPORTANT! Before using
SW3
again,
make sure the divider inside the tank and
the nebulizers have been reassembled cor-
rectly. Do not use the appliance without the
divider or the nebulizers as this could lead to
serious damage.
WARNING! We strongly advise, after aspi-
rating liquids or solids, to rinse the appliance
inside and any accessory used, by emptying
the tank and aspirating 1-2 litres clean water.
Also, please do not leave any aspirated
liquid inside the tank, to prevent the forma-
tion of limescale or moulds, and consequen-
tly bad odours.
EASY CLEN SYSTEM™
No need to store up on bags or filters thanks to EASY CLEAN SYSTEM™. Cleaning the
purification tank is all that is required for top
SW3
efficiency. At the end of your work,
empty the liquid waste of the purification tank as shown in Fig.15. To make this opera-
tion easier, the divider inside the tank can be taken off (Fig.16) and it is also advisable
to remove the nebulizers (Fig.17). Rinse tank, divider and nebulizers with abundant hot
water and neutral detergent until all residues and stains on the tank walls have been
removed.
Figure 16
Figure 17
Figure 15
WARNING! When you take off the divider, make sure that it is put back correctly
into the proper guides with its curved side looking forwards and upwards and
that it touches the bottom (otherwise it won’t slide in).
15