Make sure that any lifting equipment is of adequate
capacity to lift and move the storage tank.
Cut the straps (1) to remove the tank from the pallet.
On
SILOS 300 M - 500 M - 1000 M - 1500 M
models the
straps are located under the insulation at the hinges.
The storage tanks are fitted with a plug (2) into which you
can screw a lifting eyebolt (Ø 10 mm). Make sure that
the eyebolt is strong enough to lift the weight of the tank.
To lift
SILOS 2000 - 3000 - 5000
storage tanks, first
remove the insulation, then attach a rope of adequate
strength to the top of the tank before proceeding to lift
with great care.
b
Wear suitable personal protective equipment and
use suitable safety devices.
a
Do not leave packaging material within the reach of
children, since it can become a potential hazard.
SILOS
solar storage tanks can be installed in any room where there is no specific requirement for an electrical protection
rating higher than IP X0D.
b
The room where the appliance is installed must, however, be dry to prevent the formation of rust.
b
Respect the minimum specified installation distances to ensure correct installation and access for maintenance.
When installing SILOS solar storage tanks in old systems or systems requiring modernisation, always perform the fol-
lowing checks
- Make sure that the system is fitted with safety and control devices in accordance with applicable legislation and standards.
- Make sure that the system has been flushed out to remove all sludge and lime scale, and has been vented and seal tested.
1
2
1
1
Handling
SILOS 300 M - 500 M - 1000 M - 1500 M
SILOS 2000 - 3000 - 5000
Place of installation
Installation in older systems and systems requiring modernisation
Содержание SILOS 2000