SycoTec HF Inverter e@syDrive 4624 Скачать руководство пользователя страница 6

 
 

EN

 

9.0 Analog Input 

 

Pin 

Name 

I/O 

Meaning 

44 

10Vout 

10 V auxiliary voltage 

45 

10Vin 

Speed reference value 

46 

GND 

I/O 

Ground 

47 

0-20mA+ 

Speed reference value 

48 

0-20mA- 

Reference point of Pin 47 (0-20mA+) 

 

The analog input can be used as input for the rated speed. 
The voltage range is between 0 and 10 V, and the resolution is 16 bits. 
A potentiometer (4.7 k

Ω

 or 10 k

Ω

) can be connected or an external DC power supply can be used. 

The current range is between 0 and 20 mA, and the resolution is 16 bits. 

 

 

 

10.0 Digital Inputs 

 

Pin 

Name 

I/O 

Meaning 

52 

24 V 

24 V auxiliary voltage 

53 

GND 

I/O 

Ground 

54 

DIN1 

Start/Stop 

55 

DIN2 

Reset 

56 

DIN3 

Off 

57 

DIN4 

Off 

58 

DIN5 

Parameter import 

59 

DIN6 

Parameter export 

 

The digital inputs "

DIN1…DIN6

" can be configured with the SycoDrive operating software as needed. 

An internal 24 V DC auxiliary voltage (max. 0,5 mA) is available from the frequency inverter.  

 

 

 

11.0 Micro SD Card 

 

Error log 

With a micro 

SD card, it is possible to read out the frequency inverter’s error log with associated timestamp, 

from the time that the micro SD card was connected.  

 

Loading the parameters 

Parameters can be saved to a micro SD card and then be read out again from the card.  

 

For parameter import from the SD card to the frequency inverter, DIN 5 has to be configured for Parameter 
import and 24 V must be connected to DIN 5. In addition a restart of the frequency inverter or a reset via a 
digital input (only when the motor is stopped) must be initiated. 
After a successful parameter import, the green LED flashes twice. If an error occurs during parameter 
import (no or faulty SD card), the red LED flashes twice. 
The values of the parameters are limited to the valid values during the import. 
 

 

Содержание HF Inverter e@syDrive 4624

Страница 1: ...Short Instructions for Use EN HF Inverters e syDrive 4624 4625 4626 ...

Страница 2: ... Products 3 3 0 Connections 3 4 0 Supply Input 4 5 0 Motor 4 6 0 Safe Torque Off 5 7 0 Relays 5 8 0 Motor Temperature Sensor 5 9 0 Analog Input 6 10 0 Digital Inputs 6 11 0 Micro SD Card 6 12 0 SycoDrive Operating Software 7 12 1 Configuration and Commissioning 7 12 1 1 Operation with SycoDrive operating software 8 12 1 2 Operation with digital analog inputs 9 12 2 Diagnosis 10 13 0 Switch on sequ...

Страница 3: ...alid for following high frequency inverters HF Inverter e syDrive 4624 Material no 2 002 1053 HF Inverter e syDrive 4625 Material no 2 002 1054 HF Inverter e syDrive 4626 Material no 2 002 1055 3 0 Connections 1 Supply input max 70 V DC 49 V AC 1 3 2 Motor U V W 10 13 3 Safe Torque Off 20 27 4 Relays 30 35 5 Digital inputs PLC 50 59 6 CAN interface 60 63 7 Motor temperature sensor 40 41 8 Frequenc...

Страница 4: ...4626 the following must be observed DANGER AC voltage max 49 V AC DC voltage max 70 V DC 5 0 Motor Pin Name I O Meaning 10 U O Motor phase U 11 V O Motor phase V 12 W O Motor phase W 13 PE Protective conductor Before connecting or disconnecting the motor make sure that the frequency inverter is disconnected from the power supply When connecting the motor to U V W and PE ensure that the cable shiel...

Страница 5: ... 22 are connected to 24 V 24 26 and STO1 21 and STO2 23 are connected to GND 25 27 If the safety function is not required bridge the necessary pins 7 0 Relays Pin Name I O Meaning 30 NO O Normally open Relay 1 Motor runs 31 COM Common Relay 32 NC O Normally closed Relay 1 Motor runs 33 NO O Normally open Relay 2 Failure 34 COM Common Relay 35 NC O Normally closed Relay 2 Failure The functions of t...

Страница 6: ...figured with the SycoDrive operating software as needed An internal 24 V DC auxiliary voltage max 0 5 mA is available from the frequency inverter 11 0 Micro SD Card Error log With a micro SD card it is possible to read out the frequency inverter s error log with associated timestamp from the time that the micro SD card was connected Loading the parameters Parameters can be saved to a micro SD card...

Страница 7: ... supply can be used to connect the PC to the frequency inverter You will also need the SycoDrive operating software which can be downloaded free of charge from the website www sycotec eu Connection Install the SycoDrive operating software on your PC Open SycoDrive Switch on the frequency inverter Connect the PC to the frequency inverter the frequency inverter will detect the COM port automatically...

Страница 8: ... Operation with SycoDrive operating software For operation using the SycoDrive operating software please configure the following parameters on the STARTPAGE as shown Input for Start SycoDrive Input for rated frequency SycoDrive Then confirm the parameters with the Save on inverter button in order to transfer them to the inverter ...

Страница 9: ...s shown Input for start Digital inputs Input for rated frequency Analog input Then select the following in the INPUTS OUTPUTS menu DIN 1 Start Stop AIN U 0 10 V The parameters Maximum voltage and Maximum frequency allow the analog input to be scaled Then confirm the parameters with the Save on inverter button in order to transfer them to the inverter ...

Страница 10: ... safety reasons it is not possible to switch on the inverter and simultaneously indicate the start command and the setpoint A deliberate command must be executed to start the motor Note the following switch on sequence 1 Switch on the inverter 2 Wait during the initialization process until the inverter is ready for operation 3 Set the setpoint 4 Give the start command ATTENTION Do not switch off t...

Страница 11: ...er handling cleaning or maintenance non compliance with the maintenance operating or connecting instructions corrosion impurities in the air supply or chemical or electrical influences which are unusual or not admissible in accordance with SycoTec s standards The warranty claims shall become null and void if defects or their consequences can be attributed to interventions in or modifications to th...

Страница 12: ...EN 2 002 1913 2018 08 D DE original ...

Отзывы: