background image

 

sy.uk 

V1.0

 

 

The SIGNAL LED will remain OFF for any of the following conditions: 

1.

 

The HDMI source is not outputting data, the HDMI cable is either not connected or 
it is faulty. 

2.

 

The HDMI display is not connected or powered up, or the HDMI cable is faulty. 

3.

 

The HDMI display is not set to use its HDMI input. 

IR – Dual Bidirectional 

To use the IR Extender option, point your IR remote control device at the IR detector 
connected to the IR IN socket of either the SY-HDBT-70R or the SY-HDBT-70T as required. An 
IR emitter must also be connected to the corresponding transmitter or receiver IR OUT 
socket. Locate the IR emitter close to the device you wish to control.  All IR control functions 
are now possible from the remote location. 

RS232 – Bidirectional 

To use the RS232 extender option, connect the RS232 equipment to the RS232 terminal 
blocks with the cables provided and ensure that any RS232 handshake modes are set to 
none or RTS/CTS as required. The MODE switch on both the extender units must the set to 
Norm to allow RS232 control signals to pass between them. All standard RS232 baud rates 
up to 115.2 K baud are supported without needing to set any switches or special 
configuration options. 

The RS232 port also supports RTS/CTS flow control using the RT/CT connections. If RTS/CTS 
flow control is not required, then the RT/CT connections could be used as a second RS232 
port. 

ARC, S/PDIF and Stereo Audio (L/R) 

These extenders also support ARC from the receiver to the transmitter for sending the off-
air broadcast audio signal down to an ARC sound receiver. The ARC70 set will automatically 
select one of the following three audio modes: 

1.

 

HDMI ARC – ARC mode is selected when the 3.5mm jack sockets are left unused. 

2.

 

S/PDIF – Optical audio mode is selected when the 3.5mm jack socket detects 
that an optical fibre is connected. 

3.

 

Stereo Analogue Audio – Analogue audio is selected when the 3.5mm jack 
socket detects that a jack plug is connected. 

PoC 

The SY-HDBT-70 Extender set have a Power over Cable (PoC) capability, allowing both the 
Transmitter and Receiver units to be powered using only one power supply.  The set can be 
powered from either the Transmitter side or the Receiver side.   

For best results, use only solid copper cat6 cables. 

Содержание HDBT-ARC70-R

Страница 1: ...et Salford Greater Manchester M5 4TH United Kingdom Tel 44 0 161 868 3450 Fax 44 0 161 868 3459 www sy co uk Installation Guide SY HDBT ARC70 Extender Set with HDMI IR RS232 ARC and Power over 70m of...

Страница 2: ...receiver HDMI port to the transmitter HDMI port Supports both analogue L R or digital S PDIF audio from the receiver to the transmitter only Only one 48V DC power supply required at the Transmitter o...

Страница 3: ...cable to the HDBT sockets of both the transmitter and receiver units Connect the 48V power supply to either the Transmitter or the Receiver unit Status LEDs The LINK LED indicates the link status of t...

Страница 4: ...low RS232 control signals to pass between them All standard RS232 baud rates up to 115 2 K baud are supported without needing to set any switches or special configuration options The RS232 port also s...

Страница 5: ...switch should be set to Norm to permit transmission of RS232 signals between the two extenders The Prog setting is only used when either the SY HDBT ARC70 T or the SY HDBT ARC70 R require a field upgr...

Страница 6: ...gue L R Link Transmission Distance Up to 70 metres 1080p or 40m 4K with Power over Cable PoC IR Control 38kHz carrier frequency for any control protocol RS232 Supports Tx Rx RTS and CTS any RS232 baud...

Страница 7: ...30 12 4 2 2 8 91 50 8 4 2 2 9 90 50 10 4 2 2 9 28 60 8 4 2 0 8 91 RJ 45 Wiring Both connectors must be wired identically HDBaseT signals will not pass through any Ethernet device the HDBaseT port on...

Страница 8: ...tact with these products After Sales Service 1 Should you experience any problems while using these products firstly refer to the Troubleshooting section in this manual before contacting SY Technical...