Filter Change Instructions
Ejection
Port
October 2021
ENGLITVMAXFILTER A
2
Important Notes / Warnings
When to change the Vortex MAX filter
•
Replace filter only; do not clean or re-use filters.
Re-using filters can cause filter failure. Replace with
genuine Sy-Klone filters only.
•
When cleaning equipment, care should be taken to
prevent high-pressure water or high-pressure air from
entering the Vortex MAX ejection port.
•
When replacing the filter, do not point ejection
port at a solid surface in close proximity to the
port, as ejected debris exits at high velocity and
may damage glass, paint, or other surface area.
•
Replace the Vortex MAX filter when the restriction reaches
the manufacturer’s suggested limit.
•
Change the Vortex MAX filter element every 1000 hours of
operating time, even if the restriction limit is not reached
and there are no noticeable performance changes.
•
Replace factory-installed engine filter(s) per the
manufacturer’s suggested maintenance cycle.
1. Work in a clean, covered area to reduce intake exposure to harmful particles.
2. Wear appropriate personal protection equipment, such as gloves, mask, and
coverall to protect against contaminants.
3. The machine should be off.
4. Inspect the Vortex MAX system for any damage.
5. Remove the filter, noting the orientation of the ejection port.
6. Bag and seal the used filter element and dispose of according to local regulation.
7. Inspect and remove any loose debris using a clean rag.
Note:
Never use compressed air.
8. Install new filter, ensuring the ejection port orientation is correct.
9. Install the motor assembly, ensuring it is properly locked in position.
10. After installing the new filter, inspect the Vortex MAX system for proper
operation:
a. System is running.
b. Air flow out of Vortex MAX system ejection port is strong.
Replacing the Vortex MAX Filter
1. The machine
should be off.
2. Unplug
wiring
harness from
motor
assembly.
Wiring
Harness
Filter Removal
Wiring Harness
Filter
Handle
for easy