SY-KLONE ADVISOR RESPA Скачать руководство пользователя страница 8

Operation

 

Manual

Sy

Klone.com/RAinfo

June

 

2021

ENGLIT0000342

 

D

8

Main Menu Screen

Section 5: User Options

Setting Options

User-specific options can be changed in the 

Main Menu 

screen

. To enter the user options, the PIN code must be 

entered. The default setting is 56538. 

(See PIN Code 

Setting, page 11) 

To enter the 

Main Menu screen

:

1. Press the 

Main Menu button 

on the main display.

2. Enter PIN code. 

(Default: 56538)

If you enter code incorrectly, press 

Reset button 

to 

clear entry.

3. Press the 

Confirm button 

on the PIN Code screen to 

enter the Main Menu screen. 

Alarm Volume Setting

1. Use the 

Up/Down Volume button 

to adjust the alarm volume 

or press the 

Reset button 

to return the volume to the default 

(75% of maximum volume level).

2. Press the 

Confirm button 

to confirm any changes and return 

to the main menu screen.

To exit without saving changes, press the 

Main Menu button

or 

Cancel button 

to return to the Main Menu screen, or press the 

Home button 

to return to the main display.

200

1000

1

000

20

CO

2

FEFF218

PF ISO 35 H

H13 HEPA

50

Main 

menu 

button 

1 2 3 4

6

5

7 8 9

0

Confirm button 

Reset button 

Home 

button 

Confirm 

button 

Cancel 

button 

Adjust 

volume 

button 

Volume 

display 

Home 

button 

Reset

button 

Main 

menu

button 

Pa

H

2

O

0000

CO

2

Alarm menu

Pressure unit 

selection menu

Home button

Info button

Bluetooth menu

Data logging menu

CO

2

setpoint menu

PIN code menu

Filter selection 

menu

Filter life menu

Pressure setpoint 
menu

Содержание ADVISOR RESPA

Страница 1: ...OPERATION MANUAL Sy Klone com RAinfo In cab Main Module External Ambient Pressure Sensor APS ISO 23875 Compliant ...

Страница 2: ...Hardware Setup 6 Manual Filter Identification 7 Manual Filter Setup 7 Section 5 User Options Setting Options 8 Alarm Volume Setting 8 Pressure Units of Measure Setting 9 Pressure Alarm Setting 9 Filter Life Setting 9 Filter Identification Specifications 10 Mute Length Setting 11 CO2 Alarm Threshold Setting 11 Pin Code Setting 11 Section 6 User Operation Filter Identification 12 Filter Life Screen ...

Страница 3: ... cab Storage Temperature Rating 55 C to 125 C Operating Pressure Range 0 to 400 Pascal Pa 0 to 1 61 Inches H2O Operating CO2 Range 0 to 5000 ppm Display Resolution 1 Pa 0 01 Inches H2O Weight Main Module 426 0 g 15 0 oz Ambient Pressure Sensor 368 5 g 13 1 oz Connector Deutsch part number DT04 2P E005 qty 1 W2P secondary lock qty 1 0460 202 16141 contact pins qty 2 Dimensions Main Module 164 8 x 7...

Страница 4: ...ep to establishing better visibility to operator enclosure conditions on your job site Before installing the monitor we encourage you to read through the full operation manual including mounting and wiring instructions and download the RESPA Advisor smart phone app Additional information and support is available online or through your authorized Sy Klone reseller Access Online Support Resources Vi...

Страница 5: ...cab in a non pressurized protected area such as the exterior rear wall where it will not be impacted by dirt exposed to wind or direct airflow during machine movement or exposed to excessive moisture To assist in mounting the APS an optional APS mounting wiring kit that attaches to an existing RESPA mount which includes mounting adapter bolts and a wiring Y harness to connect to the RESPA power so...

Страница 6: ...be used for main module installation If needed Sy Klone offers a wiring harness kit RCF2915 that includes 20 feet of wire with Deutsch connector and heat shrink zip ties and clamps to secure cable Wiring both units The monitor power leads can be connected to any convenient DC voltage connection point meeting these criteria The supply voltage must be between 10 VDC and 28 VDC The voltage source is ...

Страница 7: ...n button 2 4 or 6 8 to manually install the selected filter into the install filter display 3 The installed filter will then populate in the Installed Filter display and the filter location will turn black to indicate a filter has been installed 4 Press the Confirm button when all selections are correct and return to the main menu To exit without saving changes press the Main Menu button or Cancel...

Страница 8: ...adjust the alarm volume or press the Reset button to return the volume to the default 75 of maximum volume level 2 Press the Confirm button to confirm any changes and return to the main menu screen To exit without saving changes press the Main Menu button or Cancel button to return to the Main Menu screen or press the Home button to return to the main display 200 1000 1 000 20 CO2 FEFF218 PF ISO 3...

Страница 9: ...s below 1 Use the Up Down Filter Selection buttons to select the installed filter you would like to adjust 2 Use the Up Down Adjust Hours buttons to adjust the filter life hours The maximum allowable time is determined by filter type See Filter Identification Specifications next page 3 If you wish to restore default value press the Reset button to return the filter life hours to maximum allowed 4 ...

Страница 10: ...Filter PF F9 MERV 16 STD FEFF208 750 FEFF209 Extended Length F9 MERV 16 Fresh Air Ported Filter PF F9 MERV 16 EXTD FEFF209 1000 FEFF210 Standard Length H13 HEPA Recirc Air Closed Filter PF H13 HEPA STD FEFF210 500 FEFF211 Standard Length F9 MERV 16 Recirc Air Closed Filter PF F9 MERV 16 STD FEFF211 750 FEFF212 Extended Length F9 MERV 16 Recirc Air Closed Filter PF F9 MERV 16 EXTD FEFF212 1000 FEFF...

Страница 11: ...current PIN code 1 From the main display screen press the Main Menu button 2 Enter 999999999 nine 9 s in the settings PIN Code screen 3 Press the Confirm button to enter the Main Menu and create a new 5 digit PIN code in the PIN Code Menu To create a new PIN code NOTE Only 5 digit PIN codes can be created and saved 1 Enter the current PIN code to access the Main Menu 2 Press the PIN Code Menu butt...

Страница 12: ...n Press Filter Identification display on the Home screen to enter Filter Life screen The maximum filter life hours are determined by the filter type See Filter Identification Specifications page 10 The filter life bar will diminish from right to left All installed filters can be viewed by using the Up Down Filter Selection buttons Press the Home button to return to the main display 200 1000 1 000 ...

Страница 13: ... the monitor is reset cycled off on The audible alarm generated by the primary set CO2 PPM alarm threshold can be muted See Muting the Alarm page 14 If the CO2 PPM level reaches 2500 PPM the secondary non adjustable CO2 PPM alarm will sound and it is only able to be muted for a set interval between 0 10 minutes until cab conditions return to within thresholds Filter Life Warning and Alarm When the...

Страница 14: ...larm button to silence the audible alarm The Silence Alarm button will remain until the alarm condition is resolved ENGLIT0000342 D 14 Silence Alarm Button Alarm Button Bluetooth Setting If the background of the Pressure Display on the main display is not showing Red Amber or Green the APS has not connected Reconnecting Instructions 1 To restart cycle power to the RESPA Advisor 2 If the APS does n...

Страница 15: ...ogging Download Please visit www sy klone com RAinfo or scan the QR code provided in the information screen for instructions on how to access to the Sy Klone phone application 1 On the monitor press the Download Logs button to allow the Sy Klone phone application to connect to the RESPA Advisor 2 Follow the prompts within the Sy Klone phone application to download the logs to your mobile device 3 ...