background image

Rocker Switch 
 
The rocker switch at the base of the unit will override any current setting.  If 
the device is ON, the switch will turn it OFF, if OFF, it will turn the device 
ON. 
 
If  the  device  is  in  Delayed  OFF  mode  and  the  light  is  ON,  the  switch  will 
turn the light OFF. 
 
Set Clock time 
 
NOTE -  The clock time must be set first or  you can not set the timer 
ON or OFF times.   

1. 

Position  the  Display  Time  slide  switch  to  the  Middle  position  of 
CLK SET (Clock Set). 

2. 

Position  the  Operating  Mode  slide  switch  to  Left  position  of 
MAN/PRGM (Manual / Program)  

3. 

Depress  the  UP  or  DOWN  button  and  hold  for  2  seconds,  the 
time will begin to scroll slowly in the direction you have selected.  
After  10  seconds,  the  time  will  scroll  rapidly.    There  is  an  AM  / 
PM indicator that will appear to indicate morning or evening. 

 

Reset 
Holding  down  both  the  UP  and  DOWN  buttons  simultaneously  for  5 
seconds will reset the CLOCK time.   
The  Timer  programmed  times  will  not  be  reset;  they  are  stored  in  solid 
state memory indefinitely. 
 
Note:  During a power failure the LCD screen display will be blank.  When 
the power is restored the Clock time will be re-displayed. 
 
Set Timer ON / OFF times 
Setting  the  timer  ON  and  OFF  times  is  only  required  one  time.    Once  set 
up the programmed times are stored in solid state memory and need never 
be  programmed  again.    Even  if  you  encounter  a  power  failure  the  timer 
times will not be lost. 
 
Timer ON / OFF: 

1. 

Position  the  Display  Time  slide  switch  to  the  Right  position  of 
TIME ON. 

2. 

Position  the  Operating  Mode  slide  switch  to  Left  position  of 
MAN/PRGM (Manual / Program)  

3. 

Depress  the  UP  or  DOWN  button  and  hold  for  2  seconds,  the 
time will begin to scroll slowly in the direction you have selected.  
After  10  seconds,  the  time  will  scroll  rapidly.    There  is  an  AM  / 
PM indicator that will appear to indicate morning or evening. 

4. 

Position  the  Display  Time  slide  switch  to  the  Left  position  of 
TIME OFF. 

5. 

Position  the  Operating  Mode  set  slide  switch  to  Left  position  of 
MAN/PRGM (Manual / Program)  

6. 

Depress  the  UP  or  DOWN  button  and  hold  for  2  seconds,  the 
time will begin to scroll slowly in the direction you have selected.  
After  10  seconds,  the  time  will  scroll  rapidly.    There  is  an  AM  / 
PM indicator that will appear to indicate morning or evening. 

7. 

Position Operating Mode slide switch to the VARI or AUTO RUN 
position to enable the timer. 

 

Operation of Manual Delayed OFF Mode: 
 
The Model LST100 /  Digital Wall Switch Timer is capable of 
leaving the light or load ON while leaving a room or building and 
automatically turning the light OFF after a factory pre-set amount of time 
after 10 minutes without user programming. This function does not interfere 
with pre-programmed times or cycles. 
 
NOTE - The clock time must be set first or you cannot use the 
Delayed OFF mode. If the Timer is in an automatic ON cycle, the 
Delayed OFF mode will not function.  

 

1.   The  manual  Delayed  OFF  mode  is  activated  by  ANY  two 

consecutive  transitions  of  one  (1)  second  or  less  of  the  rocker 
switch.  The  position  of  the  Display  switch  or  Mode  switch  is 
irrelevant.    i.e.,  If  the  load  is  ON,  turn  the  Rocker  switch  OFF 
then  ON  or  if  the  load  is  OFF,  then  turn  the  Rocker  switch  ON 
then OFF quickly. 
 

2. 

The  display  will  show  a  factory  pre-set  count  down  value  of  ten 
(10) minutes for the count down cycle. The ON indicator will turn 
on, the AM/PM indicators will turn off, the load will turn ON, and 
the time will start decrementing at one (1) minute intervals. At the 
end of the count down cycle, the load will turn OFF.  

 

3. 

The  count  down  value  can  be  changed  at  any  time  by  pressing 
the  UP  or  DOWN  buttons.  A  maximum  value  of  sixty  (60) 
minutes  or  a  minimum  value  of  one  (1)  minute  can  be  set.  The 
Delayed  OFF  can  be  stopped  before  the  end  of  the  cycle  by 
moving the rocker switch to the other position, or by moving the 
remote 3-way switch (if wired) to the other position. 

 
Technical Specifications: 
 
Model: LST100 /  
Supply: 110 - 125 VAC, 60 Hz, Neutral Line Required 
Load:   15 Amp Resistive, 5 Amp Inductive,  
 

625 Watts Incandescent, 1/2 HP Motors 

Approvals: ETL CUS Listed, Conforms to UL STD 60730-1A & 60730-2-7,  
 

Certified to CAN/CSA E60730-1 & E730-2-7,  

 

Complies with FCC Part 15, Class B Requirements 

Surge Protection: Self-protecting against 1000V Transient Voltage Spikes  
Storage Temperature: -4°F to +158°F (-20°C to +70°C ) 
Operating Temperature: +14°F to +131°F (-10°C to +5 5°C) 
5% - 95% Relative Humidity, Non-Condensing 
Memory  Backup:  Real  Time  is  protected  against  power  failure  by  internal 
battery.  The  screen  is  blank  during  a  power  outage.  Programmed  Times 
are permanently stored in system memory. 
 
IMPORTANT NOTES: 
 

1. 

Separate dimmers and photoelectric switches cannot be used in 
combination with your timer. 

2. 

It  is  recommended  that  your  timer  not  be  used  with  PAR  or  “R” 
type  outdoor  flood  lamps  or  lamps  higher  than  150  watts, since 
currents  generated  during  lamp  burn-out  could  damage  the 
timer. 

 

Warranty: 
 
LIMITED ONE (1) YEAR LIMITED WARRANTY 
 
If  within  one  (1)  year  from  the  date  of  purchase,  this  product  fails  due  to  a  defect  in 
material  or  workmanship,  Swylite  Corporation  will  repair  or  replace  it,  at  its  sole 
option, free of charge. This warranty is extended to the original household purchaser 
only  and  is  not  transferable.  This  warranty  does  not  apply  to:  (a)  damage  to  units 
caused by accident, dropping or abuse in handling, acts of God or any negligent use; 
(b)  units  which  have  been  subject  to  unauthorized  repair,  opened,  taken  apart  or 
otherwise  modified;  (c)  units  not  used  in  accordance  with  instructions;  (d)  damages 
exceeding  the  cost  of  the  product;  (e)  sealed  lamps  and/or  lamp  bulbs,  LED’s  and 
batteries;  (f)  the  finish  on  any  portion  of  the  product,  such  as  surface  and/or 
weathering,  as  this  is  considered  normal  wear  and  tear;  (g)  transit  damage,  initial 
installation costs, removal costs or reinstallation costs. 
 
SWYLITE  CORPORATION  WILL  NOT  BE  LIABLE  FOR  INCIDENTAL  OR 
CONSEQUENTIAL  DAMAGES,  SOME  STATES  DO  NOT  ALLOW  THE 
EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, 
SO  THE  ABOVE  LIMITATION  OR  EXCLUSION  MAY  NOT  APPLY  TO  YOU.  THIS 
WARRANTY  IS  IN  LIEU  OF  ALL  OTHER  EXPRESS  OR  IMPLIED  WARRANTIES. 
ALL 

IMPLIED 

WARRANTIES, 

INCLUDING 

THE 

WARRANTY 

OF 

MERCHANTABILITY  AND  THE  WARRANTY  OF  FITNESS  FOR  A  PARTICULAR 
PURPOSE,  ARE  HEREBY  MODIFIED  TO  EXIST  ONLY  AS  CONTAINED  IN  THIS 
LIMITED  WARRANTY,  AND  SHALL  BE  OF  THE  SAME  DURATION  AS  THE 
WARRANTY  PERIOD  STATED  ABOVE.  SOME  STATES  DO  NOT  ALLOW 
LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE 
LIMITATION MAY NOT APPLY TO YOU. 
 
This warranty service is available by either (a) returning the product to the dealer from 
whom  the  unit  was  purchased,  or  (b)  mailing  the  product,  along  with  proof  of 
purchase,  postage  prepaid  to  the  authorized  service  center  listed  below.  This 
warranty  is  made  by:  Swylite  Corporation,  1025  South  Semoran  Blvd.,  Suite  1093, 
Winter Park, Florida, 32792 / T: (407) 673-6544 http://www.Swylite.com 
 
Please be sure to wrap the product securely to avoid shipping and handling damage. 
 
CALIFORNIA PERCHLORATE ADVISORY 
 
“Perchlorate 

Material 

– 

special 

handling 

may 

apply, 

See 

www.dtsc.ca.gov/hazardouswaste/perchlorate.” 

 
 
 
 
 
 

Swylite Corporation 
1025 S. Semoran Blvd 
Suite 1093 
Winter Park, FL 32792 
http://www.Swylite.com 
Questions / Problems? T: +1-407-673-6544 

                       

Doc. No. 7000-0007, Rev. H 