Rocker Switch
The rocker switch at the base of the unit will override any current setting. If
the device is ON, the switch will turn it OFF, if OFF, it will turn the device
ON.
If the device is in Delayed OFF mode and the light is ON, the switch will
turn the light OFF.
Set Clock time
NOTE - The clock time must be set first or you can not set the timer
ON or OFF times.
1.
Position the Display Time slide switch to the Middle position of
CLK SET (Clock Set).
2.
Position the Operating Mode slide switch to Left position of
MAN/PRGM (Manual / Program)
3.
Depress the UP or DOWN button and hold for 2 seconds, the
time will begin to scroll slowly in the direction you have selected.
After 10 seconds, the time will scroll rapidly. There is an AM /
PM indicator that will appear to indicate morning or evening.
Reset
Holding down both the UP and DOWN buttons simultaneously for 5
seconds will reset the CLOCK time.
The Timer programmed times will not be reset; they are stored in solid
state memory indefinitely.
Note: During a power failure the LCD screen display will be blank. When
the power is restored the Clock time will be re-displayed.
Set Timer ON / OFF times
Setting the timer ON and OFF times is only required one time. Once set
up the programmed times are stored in solid state memory and need never
be programmed again. Even if you encounter a power failure the timer
times will not be lost.
Timer ON / OFF:
1.
Position the Display Time slide switch to the Right position of
TIME ON.
2.
Position the Operating Mode slide switch to Left position of
MAN/PRGM (Manual / Program)
3.
Depress the UP or DOWN button and hold for 2 seconds, the
time will begin to scroll slowly in the direction you have selected.
After 10 seconds, the time will scroll rapidly. There is an AM /
PM indicator that will appear to indicate morning or evening.
4.
Position the Display Time slide switch to the Left position of
TIME OFF.
5.
Position the Operating Mode set slide switch to Left position of
MAN/PRGM (Manual / Program)
6.
Depress the UP or DOWN button and hold for 2 seconds, the
time will begin to scroll slowly in the direction you have selected.
After 10 seconds, the time will scroll rapidly. There is an AM /
PM indicator that will appear to indicate morning or evening.
7.
Position Operating Mode slide switch to the VARI or AUTO RUN
position to enable the timer.
Operation of Manual Delayed OFF Mode:
The Model LST100 / Digital Wall Switch Timer is capable of
leaving the light or load ON while leaving a room or building and
automatically turning the light OFF after a factory pre-set amount of time
after 10 minutes without user programming. This function does not interfere
with pre-programmed times or cycles.
NOTE - The clock time must be set first or you cannot use the
Delayed OFF mode. If the Timer is in an automatic ON cycle, the
Delayed OFF mode will not function.
1. The manual Delayed OFF mode is activated by ANY two
consecutive transitions of one (1) second or less of the rocker
switch. The position of the Display switch or Mode switch is
irrelevant. i.e., If the load is ON, turn the Rocker switch OFF
then ON or if the load is OFF, then turn the Rocker switch ON
then OFF quickly.
2.
The display will show a factory pre-set count down value of ten
(10) minutes for the count down cycle. The ON indicator will turn
on, the AM/PM indicators will turn off, the load will turn ON, and
the time will start decrementing at one (1) minute intervals. At the
end of the count down cycle, the load will turn OFF.
3.
The count down value can be changed at any time by pressing
the UP or DOWN buttons. A maximum value of sixty (60)
minutes or a minimum value of one (1) minute can be set. The
Delayed OFF can be stopped before the end of the cycle by
moving the rocker switch to the other position, or by moving the
remote 3-way switch (if wired) to the other position.
Technical Specifications:
Model: LST100 /
Supply: 110 - 125 VAC, 60 Hz, Neutral Line Required
Load: 15 Amp Resistive, 5 Amp Inductive,
625 Watts Incandescent, 1/2 HP Motors
Approvals: ETL CUS Listed, Conforms to UL STD 60730-1A & 60730-2-7,
Certified to CAN/CSA E60730-1 & E730-2-7,
Complies with FCC Part 15, Class B Requirements
Surge Protection: Self-protecting against 1000V Transient Voltage Spikes
Storage Temperature: -4°F to +158°F (-20°C to +70°C )
Operating Temperature: +14°F to +131°F (-10°C to +5 5°C)
5% - 95% Relative Humidity, Non-Condensing
Memory Backup: Real Time is protected against power failure by internal
battery. The screen is blank during a power outage. Programmed Times
are permanently stored in system memory.
IMPORTANT NOTES:
1.
Separate dimmers and photoelectric switches cannot be used in
combination with your timer.
2.
It is recommended that your timer not be used with PAR or “R”
type outdoor flood lamps or lamps higher than 150 watts, since
currents generated during lamp burn-out could damage the
timer.
Warranty:
LIMITED ONE (1) YEAR LIMITED WARRANTY
If within one (1) year from the date of purchase, this product fails due to a defect in
material or workmanship, Swylite Corporation will repair or replace it, at its sole
option, free of charge. This warranty is extended to the original household purchaser
only and is not transferable. This warranty does not apply to: (a) damage to units
caused by accident, dropping or abuse in handling, acts of God or any negligent use;
(b) units which have been subject to unauthorized repair, opened, taken apart or
otherwise modified; (c) units not used in accordance with instructions; (d) damages
exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and
batteries; (f) the finish on any portion of the product, such as surface and/or
weathering, as this is considered normal wear and tear; (g) transit damage, initial
installation costs, removal costs or reinstallation costs.
SWYLITE CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SOME STATES DO NOT ALLOW THE
EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES,
SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS
WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES.
ALL
IMPLIED
WARRANTIES,
INCLUDING
THE
WARRANTY
OF
MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR
PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS
LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE
WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW
LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE
LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from
whom the unit was purchased, or (b) mailing the product, along with proof of
purchase, postage prepaid to the authorized service center listed below. This
warranty is made by: Swylite Corporation, 1025 South Semoran Blvd., Suite 1093,
Winter Park, Florida, 32792 / T: (407) 673-6544 http://www.Swylite.com
Please be sure to wrap the product securely to avoid shipping and handling damage.
CALIFORNIA PERCHLORATE ADVISORY
“Perchlorate
Material
–
special
handling
may
apply,
See
www.dtsc.ca.gov/hazardouswaste/perchlorate.”
Swylite Corporation
1025 S. Semoran Blvd
Suite 1093
Winter Park, FL 32792
http://www.Swylite.com
Questions / Problems? T: +1-407-673-6544
Doc. No. 7000-0007, Rev. H