background image

 

 
MODEL LST100 /  DIGITAL WALL SWITCH TIMER 
INSTALLATION & OPERATING INSTRUCTIONS

 

 
Introduction  
 
The  LST100  /    can  replace  your  regular  or  3-way  switch  (where 
two  switches  control  the  same  device)  to  control  a  light  or  any  device 
plugged  into  an  outlet  with  a  load  up  to  15  Amps  the  maximum  rating  on 
the timer label. 
 
The  LST100  /    also  has  an  exclusive  manual  On-Demand 
Delayed OFF mode that enables the user to leave the room while the light 
is ON and the timer automatically shuts the load OFF after a preset amount 
of time without interfering with programmed AUTOMATIC controls. 
 
The LST100 /  timer can control CFL & LED bulbs, incandescent 
lights, fluorescent lights, flood lights, stereos, fans and motors. 
 
You will need to use a Decorator style wall plate with this timer which is not 
supplied. 
 
The  timer  must  be  mounted  onto  a  standard  single  or  multi-ganged 
electrical box. 
 
Read wiring instructions carefully and follow guidelines applicable to 
your installation. 
 
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH 
APPROPRIATE ELECTRICAL CODES AND REGULATIONS. 

WARNING: IF YOU ARE UNSURE ABOUT ANY PART OF THESE 
INSTRUCTIONS CONTACT A QUALIFIED ELECTRICIAN. 

WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURN OFF POWER 
AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS 
OFF BEFORE WIRING! 

WARNING: DO NOT EXCEED THE 625 WATT INCANDESCENT 
RATING OF THIS DEVICE. 

CAUTION: USE THIS DEVICE WITH COPPER OR COPPER CLAD 
WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALP 
OR CU/AL. 
 
Installation Instructions 

Single Switch or 3-way to replace an existing switch: 
 
1. 

TURN OFF POWER by REMOVING FUSE or turning the CIRCUIT 
BREAKER OFF

2. 

Remove the existing wall switch. 

 
 Single Switch (Single Pole Installation): 

3. 

Connect  the  black  building  wire  from  the  Main  Power  Panel  to  the 
black wire from the timer, using the wire nuts provided.  Connect the 
blue  wire from the timer to the black wire going to the load.  Connect 
together  the  white  wire  from  the  main  power  cable  to  the  white  wire 
from the timer and the white wire to the load. 
THE  RED  WIRE  IS  NOT  USED  FOR  SINGLE  SWITCH 
INSTALLATIONS.
  Cap the red wire with a wire nut. 
BE SURE that ALL the WIRE NUTS are TIGHT and SECURE. 
 

 
 
 
 
 
 
 
 
 
 

3-way Switch Installation: 

4. 

A three way switch has three wires connected to it.  One of the wires 
is  “common”  (the  terminal  has  a  different  colored  screw  or  there  are 
markings on the old switch).  Connect the Black wire from the timer to 

the  common  wire,  Connect  the  other  two  wires  to  the  Blue  and  Red 
wires from the timer (it doesn’t matter which goes to which.) 

Connect  together  the  white  wire  from  the  main  power  cable  to  the  white 
wire from the timer and the white wire to the load. 
5. 

Tuck the wires into the wall box leaving room for the timer. BE SURE 
that ALL the WIRE NUTS are TIGHT and SECURE. 

6. 

Using  the  screws  provided,  mount  the  timer  securely  to  the  wall  box 
then install the wall plate. 

7. 

Return the power to the circuit at the service panel.  The display starts 
flashing “12:00 AM” see Operating Instructions to program the device. 

 
Alternate 3-way Switch Installation: 

 

8. 

For  alternate  3-way  Switch  Installation,  connect  each  wire  as  shown 
above. 

9. 

Tuck the wires into the wall box leaving room for the timer. BE SURE 
that ALL the WIRE NUTS are SECURE. 

10.  Using  the  screws  provided,  mount  the  timer  securely  to  the  wall  box 

then install the wall plate. 

11.  Return the power to the circuit at the service panel.  The display starts 

flashing “12:00 AM” see Operating Instructions to program the device. 

 
Controls 
 

 

Operating Modes 
 
The  LST100/  has  4  operating  modes.  The  Mode  switch 
determines which mode you are in 
 

1. 

MAN  /  PRGM  (Manual  /  Program)  this  mode  allows  the  setting  of 
the  Clock  time  and  the  Timer  ON  and  OFF  times.    In this  position 
the timer is disabled. 

2. 

VARI (Variable) in this mode the timer is enabled and the ON and 
OFF  time  settings  will  be  altered  plus  or  minus  15  minutes  to 
confuse possible intruders. 

3. 

AUTO  RUN  (Automatic  Run)  in  this  mode  the  timer  ON  and  OFF 
settings are enabled as programmed. 

4. 

Delayed OFF Mode. See Operation of Delayed OFF Mode below. 
The position of the Mode switch is irrelevant. 

DISPLAY SWITCH

MODE SWITCH

ROCKER SWITCH

DOWN BUTTON

UP BUTTON

 

AM or PM

 

INDICATOR

 

ON or OFF

 

SETTING INDICATOR

 

http://waterheatertimer.org/Programmable.html#Swilight

Отзывы: