I m p o r t a n t     S a f e t y     I n s t r u c t i o n s

This symbol warns the user of dangerous voltage levels
localized within the enclosure.

This symbol advises the user to read all accompanying
literature for safe operation of the unit.

Read, retain, and follow all instructions.  Heed all warnings.

Only connect the power supply cord to an earth grounded AC
receptacle in accordance with the voltage and frequency ratings
listed under INPUT POWER on the rear panel of this product.

WARNING:  To prevent damage, fire or shock hazard, do not
expose this unit to rain or moisture.

Unplug the power supply cord before cleaning the unit exterior
(use a damp cloth only).  Wait until the unit is completely dry
before reconnecting it to power.

Maintain at least 6 inches (15.25 cm)of unobstructed air space
behind the unit to allow for proper ventilation and cooling of the
unit.

This product should be located away from heat sources such as
radiators, heat registers, or other products that produce heat.

This product may be equipped with a polarized plug (one blade
wider than the other).  This is a safety feature.  If you are unable
to insert the plug into the outlet, contact an electrician to replace
your obsolete outlet.  Do not defeat the safety purpose of this
plug.

Protect the power supply cord from being pinched or abraded.

This product should only be used with a cart or stand that is
recommended by the manufacturer.

The power supply cord of this product should be unplugged from
the outlet when left unused for a long period of time, or during
electrical storms.

This product should be serviced by qualified service personnel
when: the power supply cord or the plug has been damaged; or
objects have fallen, or liquid has been spilled onto the product;
or the product has been exposed to rain; or the product does not
appear to operate normally or exhibits a marked change in
performance; or the product has been dropped, or the enclosure
damaged.

Do not drip nor splash liquids, nor place liquid filled containers
on the unit.

CAUTION: No user serviceable parts inside, refer servicing to
qualified personnel only.

SWR

®

amplifiers and loudspeaker systems are capable of

producing very high sound pressure levels which may cause
temporary or permanent hearing damage.  Use care when
setting and adjusting volume levels during use.

Hazardous voltages may be present within the cabinet even when
the power switch is off and the power cord is connected.
Therefore, disconnect the power cord from the rear panel power
inlet before servicing.  The power inlet must remain readily
operable.

Содержание WorkingPro 400

Страница 1: ...W WorkingPr orkingPro o Series Series BASS AMPLIFIERS BASS AMPLIFIERS ...

Страница 2: ... ...

Страница 3: ...solete outlet Do not defeat the safety purpose of this plug Protect the power supply cord from being pinched or abraded This product should only be used with a cart or stand that is recommended by the manufacturer The power supply cord of this product should be unplugged from the outlet when left unused for a long period of time or during electrical storms This product should be serviced by qualif...

Страница 4: ...ify Your Future Read through this Owner s Manual before using your amplifier not only to ensure your safety and protect your investment but so the full potential of the SWR WorkingPro is at your command Please verify that the following items were included in your SWR WorkingPro packaging AC Cable Dual Footswitch SWR Catalog A INPUT Plug your bass into this jack using a shielded instrument cable B ...

Страница 5: ...opens up the sibilance characteristics of all instruments without being harsh Your ears are the best judge when it comes to settings that affect the tone of your instrument Obviously numbers curves and circuits mean nothing if not heard with your own ears So play a chord a repeated lick or a harmonic and turn the AURAL ENHANCER control to various points on the knob to hear the effect for yourself ...

Страница 6: ... CUTOFF to 80Hz 4 Play a note repeatedly low E or low A and slowly rotate CUTOFF clockwise You will hear additional frequencies being boosted as you turn the dial and the overall effect will seem louder because more frequencies are being boosted As always your ears are the best judge Take some time to experiment and hear what works best L LIMITER This circuit is located after MASTER Volume and bef...

Страница 7: ...vier such as 16 or 14 gauge for speaker connections Shielded instrument cable WILL NOT work and may damage your equipment IMPEDANCE GUIDELINES Use the impedance ratings on your amplifier and speakers to determine if a particular combination of speakers is appropriate for your amplifier NOTE All SWR bass speaker enclosures as well as most others are wired in parallel NOT in series therefore these I...

Страница 8: ...nits except their MASTER Volumes Set EFX BLEND on all auxiliary units fully to WET 3 Recording or Reinforcement Connect EFFECTS SEND to the sound equipment input 4 Accompaniment Connect a CD player or drum machine to EFFECTS RETURN Control the input level at its source and by using the EFX BLEND control J T FOOTSWITCH Plug in the included footswitch here Use the footswitch to remotely switch MUTE ...

Страница 9: ...ils We recommend that at least once a month you remove the WorkingPro from the case and tighten all outside screws and wipe off the outside of the chassis with a damp cloth Then check all the connections in your rack case and reinstall the unit MODEL WorkingPro 400 WorkingPro 700 PART NUMBERS 4450200010 120V 60Hz USA 4450000010 120V 60Hz USA 4450203010 240V 50Hz AUS 4450003010 240V 50Hz AUS 445020...

Страница 10: ... USA SWR and WorkingPro are trademarks owned by Fender Musical Instruments Corporation Other trademarks are property of their respective owners 2005 FMIC All rights reserved WorkingPro Series Bass Amplifiers swrsound com 01 05 ...