background image

BOOT

CABLE

CABLE CLAMP

COUPLING RING

CORD CONNECTOR

STEP 2:

FEED THE FREE END OF CABLE THROUGH BOOT, CABLE CLAMP,

AND COUPLING RING IN THE ORDER SHOWN.

NOTE: CUT-OFF END OF BOOT FOR LARGER THAN 0.280"

            DIAMETER CABLES. 

STRIP CABLE END AND CONDUCTORS AS SHOWN.

CRIMP CONDUCTORS TO CONTACTS.

USE CRIMP HAND TOOL EN3CR OR PNEUMATIC CRIMP TOOL

EN3CRAUTO WITH #26 POSITIONER EN3POS26.

INSERT CONTACTS TO CONNECTOR HOUSING PER CONTACT

ARRANGEMENTS AND INSERTION INSTRUCTIONS.

CRIMP

CUT-OFF END OF BOOT HERE FOR

LARGER THAN 0.280" DIA. CABLES

EN3™ SERIES FIELD ASSEMBLY INSTRUCTIONS FOR CRIMP CONTACTS:

CONTACTS

STEP 3:

ALIGN TABS OF COUPLING RING WITH NOTCHES OF

CORD HOUSING AND PUSH COUPLING RING ONTO

CORD HOUSING.

STEP 4:

ALIGN CABLE CLAMP AND PUSH FORWARD UNTIL IT

SNAP-LOCKS ONTO THE REAR OF CONNECTOR HOUSING.

TURN NUT OF CABLE CLAMP COUNTERCLOCKWISE

UNTIL CABLE CLAMP TIGHTENS AGAINST CABLE.

STEP 5:

PUSH BOOT ALL THE WAY FORWARD, OVER

CABLE CLAMP, UNTIL FRONT END OF BOOT

SEALS TIGHTLY ONTO CONNECTOR HOUSING.

.75 19.1

.156 4.0

CABLE

CONDUCTOR

CONTACT

LOCKING DISC

CORD HOUSING

 

 

INSERTION

HAND TOOL

TYPICAL CONTACT INSERTION INSTRUCTIONS:

PLACE CONTACT IN GROOVE OF INSERTION HAND TOOL

EN3INS26

. NOTE: TIP OF TOOL SHOULD BE UP AGAINST

THE SHOULDER OF CONTACT.

INSERT CONTACT INTO CORRECT CAVITY OF CONNECTOR

BODY BY APPLYING CONSTANT PRESSURE UNTIL

CONTACT BOTTOMS UP AGAINST LOCKING DISC.

NOTE: DO NOT TILT TOOL DURING THE INSERTION.

REPEAT ABOVE PROCEDURE TO INSERT ALL CONTACTS

PER CONTACT ARRANGEMENTS.

CORD WIRING SIDE VIEW

NOTCH,

PIN #1 INDICATOR 

CABLE CLAMP WITH NUT

IN POSITION

CABLE CLAMP

NUT

STEP 1:

PRESS THE TWO WINGS OF CABLE CLAMP INWARD, THEN THREAD NUT CLOCKWISE ONTO CABLE CLAMP

TO THE POSITION SHOWN.

Содержание EN3 Series

Страница 1: ...l Shock Mil Std 202 Method 213B Condition K Vibration Mil Std 202 Method 201A Life 600 insertion withdraw cycles minimum Electrical Voltage Rating Sea Level Tested at 600 VRMS Insulation Resistance 100 megohms minimum at 77 F Contact Resistance 5 milliohms maximum Current Rating 3 Amps Environmental Temperature Limits 40 C to 65 C non operating Moisture Resistance Mil Std 202 Method 106F Insulatio...

Страница 2: ... 2 9 PIN 10 3 4 5 6 7 8 9 2 10 PIN 10 3 4 5 7 8 9 1 11 11 PIN 10 3 4 5 6 7 8 9 1 11 2 2 12 PIN 10 3 4 5 6 7 8 9 1 11 18 2 13 PIN 10 3 4 5 6 7 8 9 1 11 13 16 582 14 8 610 15 5 83 21 0 30 7 5 53 13 5 13 3 2 CRIMP CONTACTS SHOWN 5 8 27 THREAD RECOMMENDED PANEL CUT OUT 0 003 0 08mm PANEL 81 20 6 PIN 1 INDICATOR 2 00 50 7 2 27 57 6 71 18 0 Cable End Panel Mount Contact Arrangements Wiring View of Cable...

Страница 3: ... Cup Leave blank for Straight Solder Cup Packaging Options K Kit Leave blank for Bulk Cable Clamp system option L for 0 230 to 0 380 cable nom O D and 0 750 long stripping Leave blank for 0 160 to 0 265 cable nom O D and 0 380 long stripping Contact plating AG Silver Leave blank for Gold Notes 7 and 8 pin not available in male Cord or In Line connector 7 and 8 pin not available in female In Line c...

Страница 4: ...L IT SNAP LOCKS ONTO THE REAR OF CONNECTOR HOUSING TURN NUT OF CABLE CLAMP COUNTERCLOCKWISE UNTIL CABLE CLAMP TIGHTENS AGAINST CABLE STEP 5 PUSH BOOT ALL THE WAY FORWARD OVER CABLE CLAMP UNTIL FRONT END OF BOOT SEALS TIGHTLY ONTO CONNECTOR HOUSING 75 19 1 156 4 0 CABLE CONDUCTOR CONTACT LOCKING DISC CORD HOUSING INSERTION HAND TOOL TYPICAL CONTACT INSERTION INSTRUCTIONS PLACE CONTACT IN GROOVE OF ...

Отзывы: