LED Panel Instruction
Specification
Packing List
Product appearance
8
7
6
5
1
2
3
4
Fig2
Fig3
①
Battery plate
②
4-pin XLR DC charging socket
(Pin 1: Negative, Pin 3: Positive)
③
On/Off
④
LED display panel
⑤
⑧
Fuse holder
⑥
⑦
DC output
S-4010
S-4030
S-4020
⑥
⑦
4-pin XLR DC output socket
(Pin 1: Negative, Pin 4: Positive)
⑥
⑦
3-pin XLR DC output socket
(Pin 1: Negative, Pin 2: Positive)
⑥
3-pin XLR DC output socket
(Pin 1: Negative, Pin 2: Positive)
⑦
4-pin XLR DC output socket
(Pin 1: Negative, Pin 4: Positive)
S-4010
(Dual 12V output)
S-4020
(12V/24V output)
S-4030
(Dual 24V output)
Model
Input
Output
Dimension
Net weight
Working
environment
DC 16.8V 5A
(Charging)
DC 16.8V 5A
(Charging)
DC 16.8V 5A
(
Charging
)
290mm x 221mm x 278mm
3.45Kg
Item Name
Power Station Box
Fuse(65TS-150H/L)
Charger
Power Cable
Warranty Card
User Manual
Certificate of Quality
Quantity
x1
x2
x1
x1
x1
x1
x1
DC11-16.8V
15Ax2 (180Wx2)
DC 11-16.8V 15A (180W)
Or
DC 22-33.6V 15A (360W)
DC 22-33.6V x2
Together 15A(360W)
Working temperature:
0
℃~
+40
℃
Working humidity: 10%
~
90%
Storage temperature:
-15
℃~﹢
60
℃
Trouble-shooting
Description
Possible Cause
Solution
Can not output to power
equipments, but the LED panel
display voltage
Fuse has been damaged
Change fuse
Reconnect the XLR cable.
DC output socket is not connected to the equipment
or not reliable connected
S-4020
S-4010
S-4030
“O”
:
OFF
“
∣
”
:
ON
“
-
” : 12V working mode
“O” : OFF
“
=
”: 24V working mode
Function
Model
ON/OFF state LED panel State
Charging
Discharge
S-4010
S-4020
S-4030
O
=
O
∣
No Display
The outermost ring of the LED panel displays in recycling show way and after each circle,
it will display the current voltage.
The outermost ring of the LED panel displays in recycling show way and after each circle,
it will display the current voltage.
S-4010
S-4020
S-4030
Normal Working Status:
The outermost ring of the LED panel displays in recycling show way and after each circle,
it will display the current voltage.
Not in
“O”
position
No Display
No Display
No Display
No Display
Under Voltage Alarm:
The LED panel display and flash “ ”, it indicates that the voltage of the current batteries is
lower than the under-voltage protection value.
Note:
⑴
. The under-voltage protection value for 12V operating mode is 13V
;
⑵
. The under-voltage protection value for 24V operating mode is 26V.
O
∣
-