![SWIT Electronics M-1092H Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/swit-electronics/m-1092h/m-1092h_user-manual_1415518009.webp)
3.6 GPI submenu
The “GPI” submenu includes:
⑴
GPI Control: on/off
On: User can control the monitor through GPI control unit
Off: User cannot control the monitor through GPI control
unit
⑵
Terminal1~5: Define each GPI terminal function; see details
in “4.REMOTE interface definition”
3.7 PIP submenu
The “PIP” submenu includes:
⑴
Sub Window Size: Off, Large, Small
⑵
Sub Window Position: Right-Bottom, Right-Top, Left-Bottom,
Center, Left-Top
⑶
Sub Window Source
When the input signal is SDI1/SDI2/HDMI, the PIP window
signal can only be CVBS;
When the input signal is CVBS, the PIP window signal can
be selected from SDI1/SDI2/HDMI.
4. REMOTE Interface Definition
The GPI interface is the DB9 port, the DB9 terminals definition are as below:
User can define each GPI terminal function in the “menu”. It will be on when GPI terminal connected
to GND, and off when disconnected.
Terminal 1
~
5: The functions can be set as below:
Undefined
Freeze Frame
Tally-R
Button lock
Tally-G
PIP
Tally-Y
Focus assist
SD Aspect Ratio
Audio bar
Scan
Zebra
Zoom
B/R/G Only
Mono
Timecode
DB9
1
2
3
4
5
6
7
8
9
GPI
GPI_1
GPI_2
GPI_3
GPI_4
GPI_5
VCC_OUT
485B(Rx-)
485A(Rx+) GND