background image

Swissphone Telecommunications AG 

manual RE529 V1_00.doc

September  25

th

 2003

Fälmisstrasse 21 // 8833 Samstagern

edition 1.00

Switzerland

PMA/D000xxx

page 3/7

1.5  Switching On / Keys

If the unit is switched off, you can switch on the pager operation by 

simultaneously 

pressing both

operating keys SELECT(1) and EXECUTE(2). 

As a rule, a self-test takes place every time the unit is switched on, and briefly displays the following
check pattern.
1)  Display of the programmed operational functions by symbols

in the display and sequential display of enabled addresses.

2)  Control beeps
3)  The LED lights up
4)  Short-term vibration

1.6  Selecting the Operating Status

The operation of the unit is very simple and ergonomic, and is designed for a high level of operational
security. The keys are located in the upper left and right corners of the unit. The left-hand key (1) is
SELECT, and the right-hand key is EXECUTE.
With the left-hand key (1), you can select the desired operational symbol. The symbol begins to blink.
Using the right-hand key, the desired operational function can be acknowledged, and the symbol
ceases to blink in the display. The sequence takes place depending upon how the symbol selection
has been defined in the programming. Only those symbols will be sequentially displayed which have
been enabled in the programming.
After a call was found valid, the speaker is switched on to monitor the air traffic. Pressing any key will
just mute the pager. In case of a memo pager, voice recording will continue. If a squelch follow up time
was defined, the pager stays on loud until that time is expired.

select (1)

execute (2)

KEYS

Quattrino EURO

ON OFF

BAT

T

E

R

Y

Содержание Quattrino RE529

Страница 1: ...Acoustic ON 4 2 2 Mini Beep 4 2 3 Acoustic OFF 4 2 4 Monitor 4 2 5 Volume 5 2 6 Field Strength Alarm 5 2 7 Address Display Profiles 5 2 8 Choosing Profiles 5 2 9 Message Memo only 5 2 10 Battery Stat...

Страница 2: ...attery To insert the battery proceed as follows 1 Open the battery compartment by pressing down the tongue in the rear panel and pulling out the battery cover sideways If necessary use a coin as a too...

Страница 3: ...for a high level of operational security The keys are located in the upper left and right corners of the unit The left hand key 1 is SELECT and the right hand key is EXECUTE With the left hand key 1...

Страница 4: ...de you can hear everything that is spoken over the set radio channel Calls addressed to you will be signalled acoustically If you wish to switch off the continuous monitoring listening operation selec...

Страница 5: ...in the same way After confirmation 1 the field strength symbol remains visible for about 8 seconds and then disappears if the field strength is sufficient 2 7 Address Display Profiles This 3 digit di...

Страница 6: ...ly voltage of 1 24 V the switch on test takes place and the pager recognises either a battery or an accumulator The pager then stores this information If an accumulator has been inserted the rechargin...

Страница 7: ...witched on with every key switch enables you to read the operational status of your unit in the dark 3 3 Accessories For the connection of various additional units e g output to a PC printer or for ba...