background image

 

12 

Technical Data

 

Absolute Maximum ratings 

The maximum ratings of the XRC-CT15b mustn’t 
be exceeded; otherwise the device will be 
damaged. 
 
Input voltage of 
contacts (1 – 15) 
when using external 
power 

17V 

VCC current (if you 
want to power 
another device) 

250mA 

Operating Conditions 

VCC 

7V – 8V 
 

Activation Voltage 
when using external 
power 

If the voltage of a contact 
exceeds 2.5V then it’s 
activated. For another 
activation, the voltage first 
must fall below 2.0V 

Switching 
characteristic 
 

As soon as a contact is 
activated, the XRC-CT15b 
will send a command to the 
XRC-150/200. If the 
contact stays activated, 
nothing happens. To 
initiate the command 
again, the contact first has 
to be deactivated. 

Input Power 

No input power needed, 
power comes over the 
connecting cable from the 
XRC-150/200 

Software 
Requirements 

You must have software 
version 1.10 or higher 
installed on your XRC-
150/200 if you want to use 
the XRC-CT15b external 
triggers 

Operating 
temperature 

0°C to 45°C 
 

Dimensions / weight  267 mm/10.51in x 

Содержание XRC-CT15b

Страница 1: ...XRC CT15b External Trigger Contacts for XRC 150 200 User Manual ...

Страница 2: ...written permission of SWISSON AG The information in this documentation is supplied without warranty of any kind either directly or indirectly and is subject to change without prior written notice SWISSON its employees or appointed representatives will not be held responsible for any damages to software hardware or data arising as a direct or indirect result of the product s mentioned herein Issued...

Страница 3: ... XRC 150 200 6 Connection 6 Connecting Cable 7 Opening the XRC CT15b 8 Connecting contacts to the XRC CT15b 9 Using internal Power 9 Using external Power 9 Configuration of the XRC 150 10 Configuration of the XRC 200 10 Technical Data 12 Absolute Maximum ratings 12 Operating Conditions 12 Safety notes 14 ...

Страница 4: ...T15b is connected with the XRC 150 200 through this port 2 Cable Glands Glands for cables connected in the XRC CT15b 3 Lid The lid of the XRC CT15b can be removed for connection of the contacts 4 Lid Screw This screw holds the lid on the XRC CT15b ...

Страница 5: ... XRC 150 200 On this device up to 15 external trigger contacts can be connected With these contacts the XRC 150 200 can be controlled remotely Each button can be configured to start stop or pause play back of a sequence on the XRC 150 200 Contacts 1 15 XRC CT15b XRC 150 ...

Страница 6: ...CT15b can be easily connected to the XRC 150 200 through running a cable from the external port of the XRC 200 or from one of the two external ports of the XRC 150 to the XRC CT15b It doesn t matter on which port port 1 or 2 the XRC CT15b is connected to the XRC 150 ...

Страница 7: ...b to the XRC 150 200 is done with a standard RJ45 8 pole STRAIGHT network cable 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 The speed of the data transmission between the XRC CT15b and the XRC 150 200 is 250 kBaud Therefore the cable mustn t be very high quality ...

Страница 8: ...ernal trigger contacts the lid must first be removed Simply remove the lid screw Lid Screw Slide out the lid of the XRC CT15b Now you can see the connecting ports 1 15 for the external trigger contacts and also two connectors of the internal power VCC and GND ...

Страница 9: ...CC of the XRC CT15b and the other connection to a dedicated input of the device Using external Power When using external power it s necessary to connect GND of the XRC CT15b to the voltage reference ground on the external device ATTENTION When using external power you have to take attention to the maximum ratings See chapter Absolute Maximum ratings on page 12 VCC 1 2 15 XRC CT15b Voltage of exter...

Страница 10: ...ll appear on the display of the XRC 150 Now you need to choose the contact by activating it For example if you have connected a switch on contact1 press this switch to configure contact1 There are three different possible actions 1 Play Sequence This will start playback of one of the 32 different sequences the sequence can be set 2 Pause This will set the XRC 150 to pause or release the XRC 150 fr...

Страница 11: ...econd column is highlighted a menu will show up where an action may be selected Available actions are NONE PLAY PLAYLIST PLAY SEQUENCE PAUSE and STOP When a cell in the rightmost column is highlighted pressing the OK key will display a list of sequence numbers if the action of the row of the highlighted cell is PLAY SEQUENCE A list of playlist numbers will be displayed if the action of the row of ...

Страница 12: ...nother activation the voltage first must fall below 2 0V Switching characteristic As soon as a contact is activated the XRC CT15b will send a command to the XRC 150 200 If the contact stays activated nothing happens To initiate the command again the contact first has to be deactivated Input Power No input power needed power comes over the connecting cable from the XRC 150 200 Software Requirements...

Страница 13: ...13 111mm 4 37in x 45mm 1 77in 500g 1 10lbs ...

Страница 14: ...ep the device away from sources of electrical interference This device is developed for only use together with the XRC 150 200 Dynamic DMX Recorder of SWISSON AG and no other devices Clean the XRC CT15b only with a soft damp cloth Don t use chemicals or other harsh scrubbing agents Protect the device against extreme dampness liquids dust and dirt Don t use the device in places with excessive direc...

Отзывы: