23 Safety Information
Consider the following notes absolutely when you set up, connect and use the XMT.
This product is not for household use. Read this manual before operating the device, follow the safety
precautions and observe all warnings in this manual.
Use this device only in accordance with local laws and regulations.
•
Do not expose the device to rain or moisture.
•
Do not operate the device if any cover or component is missing damaged or deformed.
•
Refer any service operation not described in this manual to Swisson.
•
Provide unrestricted airflow around the device.
•
Do not operate the device if the ambient temperature exceeds 55°C (131°F).
•
Do not modify the device in any way not described in this manual or install other than genuine Swisson
parts.
•
Do not use the device in areas where it is exposed to direct sunlight.
•
Do not use the device in areas that are considered to be 'highly combustible'.
24 Technical Data
Hardware
Display type................................................LCD
Display back light.......................................LED green
Display resolution.......................................128x64 pixel
FLASH memory...........................................16MBytes
DMX in port................................................Neutrik 5-pin male connector
DMX out port.............................................Neutrik 5-pin female connector
DMX ports electrical standard...................ANSI E1.11 / ANSI E1.20
USB port.....................................................Micro USB B type
Battery........................................................9V block battery
USB Power consumption............................150mA max
Use of rechargeable battery......................Yes
Battery recharge.........................................No
Cable tester................................................5-pin, open circuit, short circuit, wrong wiring
DMX in termination....................................120 Ohm, permanent (except cable tester)
DMX out termination.................................RDM bias network, RC-termination
Operating temperature..............................0°C to +45°C / 32°F to 113°F
Dimensions.................................................119mm x 71mm x 46mm / 4.7” x 2.8” x 1.8”
Weight........................................................400g / 0.88 lbs
Firmware (XMT-120A Version 1.15, XMT-350 Version 1.02)
Received DMX channels.............................512
Transmitted DMX channels........................512
Refresh rates..............................................5, 10, 15, 20, 25, 30, 35, 44 frames per second
Transmitter break length............................140-150 microseconds / not configurable
Transmitter MAB length.............................28-32 microseconds / not configurable
Timing measurement.................................Frames per second / Break / MAB
Display formats..........................................Percents, Decimal, Hexadecimal
DMX scene storage....................................32 scenes, 512 channels each
Number of sequences................................1
Steps in sequence......................................99
Number fixture types.................................100
Channels per fixture...................................45
RDM controller...........................................XMT-120A: NO / XMT-350: YES