Swisson XMT-120A Скачать руководство пользователя страница 24

 23 Safety Information

Consider the following notes absolutely when you set up, connect and use the XMT.
This product is not for household use. Read this manual before operating the device, follow the safety 

precautions and observe all warnings in this manual.
Use this device only in accordance with local laws and regulations.

Do not expose the device to rain or moisture.

Do not operate the device if any cover or component is missing damaged or deformed.

Refer any service operation not described in this manual to Swisson.

Provide unrestricted airflow around the device.

Do not operate the device if the ambient temperature exceeds 55°C (131°F).

Do not modify the device in any way not described in this manual or install other than genuine Swisson

parts.

Do not use the device in areas where it is exposed to direct sunlight.

Do not use the device in areas that are considered to be 'highly combustible'.

 24 Technical Data

Hardware

Display type................................................LCD
Display back light.......................................LED green
Display resolution.......................................128x64 pixel
FLASH memory...........................................16MBytes
DMX in port................................................Neutrik 5-pin male connector
DMX out port.............................................Neutrik 5-pin female connector
DMX ports electrical standard...................ANSI E1.11 / ANSI E1.20
USB port.....................................................Micro USB B type
Battery........................................................9V block battery
USB Power consumption............................150mA max
Use of rechargeable battery......................Yes
Battery recharge.........................................No
Cable tester................................................5-pin, open circuit, short circuit, wrong wiring
DMX in termination....................................120 Ohm, permanent (except cable tester)
DMX out termination.................................RDM bias network, RC-termination
Operating temperature..............................0°C to +45°C / 32°F to 113°F
Dimensions.................................................119mm x 71mm x 46mm / 4.7” x 2.8” x 1.8”
Weight........................................................400g / 0.88 lbs

Firmware (XMT-120A Version 1.15, XMT-350 Version 1.02)

Received DMX channels.............................512
Transmitted DMX channels........................512
Refresh rates..............................................5, 10, 15, 20, 25, 30, 35, 44 frames per second
Transmitter break length............................140-150 microseconds / not configurable
Transmitter MAB length.............................28-32 microseconds / not configurable
Timing measurement.................................Frames per second / Break / MAB
Display formats..........................................Percents, Decimal, Hexadecimal
DMX scene storage....................................32 scenes, 512 channels each
Number of sequences................................1
Steps in sequence......................................99
Number fixture types.................................100
Channels per fixture...................................45
RDM controller...........................................XMT-120A: NO  / XMT-350: YES 

24     PRELIMINARY

Содержание XMT-120A

Страница 1: ...XMT 120A XMT 350 DMX Measurement Tool Tester USER MANUAL Distributor www techni lux com Phone 407 857 8770 Fax 407 857 8771 Email sales techni lux com...

Страница 2: ...Revisions History Revision Description Date 1 First Draft 23 08 12 1 1 Draft English XMT 120A and XMT 350 ler 09 10 12 1 3 Edited boc 22 03 13 2 PRELIMINARY...

Страница 3: ...EDIT MODE 12 13 6 REFRESH RATE 13 14 CABLE TESTER 13 15 CHANEL TRACER 13 16 TIMINGS 15 17 SEQUENCE 15 17 1 EDIT SEQUENCE 16 17 2 PLAY SEQUENCE 16 17 3 DELETE SEQUENCE 16 18 FIXTURES 16 18 1 PATCH FIX...

Страница 4: ...g analysis sequence editor channel tracer dip switch display and Min Max display this device is ideal for troubleshooting and resolving DMX 512 signal challenges and yet remains very simple to operate...

Страница 5: ...E The operating mode can be selected by pressing the mode button VALUE UP Increase DMX value NAVITGATE Use to navigate up in the user menu DISPLAY LCD display with LED backlight VALUE DOWN Decrease DM...

Страница 6: ...e refer to the Power Settings chapter on how to change this behavior 7 USB Port The USB port is used to power the XMT and to connect it to a PC Any 5V USB adapter which is capable to supply 150mA can...

Страница 7: ...MX in port If a DMX signal is received without any errors the data of the DMX signal will be displayed Choose the DMX address with CH and CH buttons The corresponding level will be shown in real time...

Страница 8: ...tons Press OK to confirm Press CANCEL twice to exit the receiver options There are 32 scenes which are accessible from the receive DMX mode as well as from the send DMX mode Storing the received signa...

Страница 9: ...Note This option only applies to the Normal display mode 12 SEND DMX Press the MODE button and choose SEND DMX Now press the OK button to enter the send mode Connect your DMX fixtures to the DMX out...

Страница 10: ...E Set the DMX refresh rate for the DMX transmitter 13 1 CLEAR ALL CHANNELS In send DMX Mode Press OK to access the send options Choose CLEAR ALL CHANNELS with the UP and the DOWN button Press OK to co...

Страница 11: ...he send options Note The scenes in receive DMX mode and in send DMX mode are shared All 512 channels are stored into a scene Storing to a scene overwrites the scene s previous content The scenes can b...

Страница 12: ...the EDIT MODE item with the UP DOWN buttons Press OK to change the edit mode The edit mode can be NORMAL or DIRECT Press Cancel to exit the send options Note The edit mode setting does not affect grou...

Страница 13: ...to the DMX out port The XMT scans all pin connections automatically If the connection between a pair of pins is OK it s indicated by a straight line connecting the pins Pin 2 is connected to pin 3 Thi...

Страница 14: ...and resume the tracing When stopped a small cursor appears The position of the cursor is displayed on the bottom right of the screen The first value shows the DMX level and the second value shows the...

Страница 15: ...ipment 44 frames per second maximum speed when sending all 512 channel 44 frames per second only possible when sending less than 512 channel Compliant to standard but may cause problems with some equi...

Страница 16: ...ease decrease the fade time 17 3 DELETE SEQUENCE Choose the DELETE SEQUENCE item with UP DOWN buttons and press OK Press OK again to confirm 18 FIXTURES Press the MODE button and choose FIXTURES Now p...

Страница 17: ...re NUMBER OF CH Number of DMX channels used by this fixture CHANNEL DEF Definition of the channel description DELETE FIXTURE Delete the fixture definition Name Use and buttons to select NAME Select th...

Страница 18: ...date of the XMT 20 1 ENTER NAME Choose the ENTER NAME item with UP or DOWN button Press OK to enter the name dialog Select the cursor position by pressing CH or CH and change the character at the curs...

Страница 19: ...OFF IF IDLE Automatic turn off time for the XMT when battery operated BACKLIGHT BRIGHTNESS Choose the BACKLIGHT BRIGHTNESS item with UP or DOWN buttons Press OK to change the backlight brightness fro...

Страница 20: ...l discovery is completed The main screen shows a list of the RDM devices discovered The device description and the DMX address is displayed for all found RDM devices The currently selected device is i...

Страница 21: ...r off with OK DEVICE DETAILS RESET WARM RESET Press OK to start a warm reset of the RDM device COLT RESET Press OK to start a cold reset of the RDM device DEVICE HOURS Operating hours of the RDM devic...

Страница 22: ...the user to know which devices has already been readdressed patched The first item on the list is RESTART PATCH Select this Item to restart the patch In this case all devices will be marked with the...

Страница 23: ...X in port is an isolated receiver Is the XMT connected to a PC the DMX in port might be a ground referenced receiver when the USB is grounded Is the XMT connected to a DMX controller with a ground ref...

Страница 24: ...y resolution 128x64 pixel FLASH memory 16MBytes DMX in port Neutrik 5 pin male connector DMX out port Neutrik 5 pin female connector DMX ports electrical standard ANSI E1 11 ANSI E1 20 USB port Micro...

Страница 25: ...25 PRELIMINARY...

Отзывы: