MOSTRAC – Motion Sensor TRAck Control 

USER’S MANUAL 

3508.500.02 l Version 1.0 l January 2021 

 
 
 

 

 

 

Содержание MOSTRAC

Страница 1: ...TD Phone 41 32 488 36 11 P O Box 138 Rue de l Envers 1 info swisstiming com CH 2606 Corgémont Switzerland www swisstiming com MOSTRAC Motion Sensor TRAck Control USER S MANUAL 3508 500 02 l Version 1 0 l January 2021 ...

Страница 2: ...right to refuse all guarantees if this condition is not fulfilled If the installation includes a horn be sure to maintain a sufficient security distance from the public Documentation Updates Swiss Timing SA reserves the right to make improvements in the products described in this documentation at any time without prior notice Furthermore Swiss Timing SA reserves the right to revise this documentat...

Страница 3: ...e V PRO FS 7 1 3 MoSen characteristics 8 1 4 Charging case 9 1 5 General cabling 9 1 6 Mechanical setup 10 1 7 Multi usage 11 2 SYSTEM SETUP 12 2 1 Configuration Start Time V FS 12 2 1 1 Base Frequency 12 2 1 2 System A B C D 12 2 1 3 Delete All 12 2 2 Pairing each lane 13 3 PREPARE THE RACE 14 3 1 Recommended Starter Position 15 3 2 Position of the antenna 15 4 RACES 16 5 APPENDICE 17 5 1 Version...

Страница 4: ......

Страница 5: ...s system is to give the start of an athletic race in lane and measure the reaction time of each athlete using any kind of starting block On competition day a motion sensor is fixed on each starting block it will detect acceleration around the start time and transmit wirelessly the reaction time to the StartTime V FS Please also refer to document 3481 560 for the usage of StartTime V and ...

Страница 6: ...iming com SWISS TIMING LTD 1 1 Material A Startime V PRO FS with antenna tripod and charger art 3481 774 B e Gun with headset and transport case art 3481 932 C 3 loudspeakers with 1x30m 2x10m cable art 3399 730 D 8 MoSen with charging case art 3508 901 E 16 fixations clip for starting block art 3508 013 F 16 double side tapes patch for clip fixation art 9038 3592 B D E C A ...

Страница 7: ...ive side 3 Start output negative side E Ready input positive side SERIAL Full duplex RS485 serial line for example to transmit reaction time to photofinish TUCHEL 7pFT 1 Power supply output 12VDC 2 Power supply output 12VDC 3 TX 4 TX 5 RX 6 RX E GND LAN This is a 100BASE T standard Ethernet connection that can be used for StartTime configuration or specific communication RJ45 PUSH 1 TX 2 TX 3 RX 4...

Страница 8: ...Certifications CE and RoHS compliant Charging connector MoSen ID Lane ID Power ON LED Status Clip Note Charging connector in red European version 868MHz Charging connector in black American and Asian version 916MHz 2 to 7s Arm start StartTime autentification 2s 2s 2s COMPETITION mode STATUS mode ON mode OFF mode 1s after start adjustable PAIRING mode until green XXX mode LED indication colour freq...

Страница 9: ...ot correctly plugged Note USB connector on charging case is used for MoSen firmware upgrade first slot only 1 5 General cabling E GUN MICRO Lane 1 to max Lane 8 START output of StartTime should be connected to timing device photofinish for example SERIAL output RS422 of StartTime can be connected to photofinish system to automatically transmit reaction time Transmission parameters 115 200 bauds 1 ...

Страница 10: ...lude in the set With screws not provided Recommended M3 conical screw The fixation clip need to be mount in right position if you will have the MoSen in the race direction The preferred location to mount the system is at the rear of the starting block where the athlete will not step on it to plant spikes of starting block Top side To fix the MoSen on the fixation just push down 1 and turn 90 the d...

Страница 11: ... used for 100m start system B used for 60m start system C used in a nearby location for training all systems used simultaneously Second application is to use different sets of MoSen on the same StartTime without need to redo the pairing For example you have a set of MoSen for 100m races paired once with StartTime Sytem A and another set of MoSen for 400m races paired once with the same StartTime b...

Страница 12: ...5sec Press the button select Sport with the press select Athletics AT with and press Press the button select ATH MoSen with the press select Setup with and press 2 1 1 Base Frequency Select Base Frequency and press Choose the correct Region with the button and press 2 1 2 System A B C D Select System A B C D and press Choose the system you want to use with the button and press 2 1 3 Delete All Sel...

Страница 13: ...lect Pair with and press Put the MoSen in paring mode by pressing on the MoSen Stay on the button upon the green led turn off 8s Now the MoSen blink with a led in blue MoSen Lane X MoSen Lane X 8s Press on the Start Time V You can now see the MoSen ID on the lane you had paired Note The MoSen turn off after the pairing process Identify the MoSen for example with provided sticker Lane 1A Lane 2A or...

Страница 14: ...h MoSen are connected You can see an example below Lane 1 to 8 are connected Lane 8 not connected powered off or bad wireless transmission Tip Only paired MoSen lane number are visible so if your track has only 6 lanes pair only 6 MoSen from 1 to 6 then numbers 7 an 8 will not be visible on above screen samples Check the battery of each MoSen Press and you can see a little battery icon for each Mo...

Страница 15: ... position for 200m Recommended starter position for 400m Alternative starter position for 400m 1 Loudspeaker 2 3 4 3 2 Position of the antenna Up to 110m races antenna can be placed on the StartTime about 1 5m height For 200m and 400m we recommend to put the antenna at least 2m above the Start Time V With this position we guarantee a good reception between the MoSen on the starting block and the S...

Страница 16: ...is automatically generated After the start reaction time can be visualized ion StartTime screen by pressing Reaction times generating an automatic false start between 0 100s and 0 099s are indicated in inversed video Reaction time with minus sign means movement before the start By default StartTime settings motion is analysed from 0 3s before the start to 1 0s after the start Reaction time measure...

Страница 17: ...one 41 32 488 36 11 P O Box 138 Rue de l Envers 1 info swisstiming com CH 2606 Corgémont Switzerland www swisstiming com 5 APPENDICE 5 1 Version history Version Date Modifications since last version 1 0 19 01 2021 Initial version ...

Страница 18: ...O Box 138 rue de l Envers 1 Phone 41 32 488 36 11 3508 500 02 docx 2606 Corgémont Switzerland Fax 41 32 488 36 09 david graf swisstiming com www swisstiming com info swisstiming com SWISS TIMING LTD NOTES ...